Opis
Polyethersulfone (PES) membranes were used to separate wastewater from car washes containing bacteria.
After the separation was completed, the UF installations were washed with chemical agents.
The study examined how effectively these chemical agents remove bacterial contamination from the installation.
P3 Ultrasil 11 alkaline solutions (pH = 12) were used to clean the UF plant.
This agent is recommended by membrane manufacturers, such as PCI, for cleaning membrane modules.
In operation, the membranes were also washed with a 0.5% Insect solution (pH = 11.5).
This detergent is used in car washes to remove insects from cars. The Insect solution, like P3 Ultrasil 11, contains NaOH and detergents.
LMH permeate flux calculated as litres per quadratic metre of membrane per hour
CFU Colony formed unit
TMP transtransmembrane pressure
PES Polyethersulfone
MPa mega Pascal
UF Ultrafiltration
Plik z danymi badawczymi
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
gdzie pojedyncza część pliku jest wielkości 512 MBPrzykładowy skrypt do wyliczenia:
https://github.com/antespi/s3md5
Informacje szczegółowe o pliku
- Licencja:
-
otwiera się w nowej karcieCC BYUznanie autorstwa
- Dane surowe:
- Dane zawarte w datasecie nie zostały w żaden sposób przetworzone.
Informacje szczegółowe
- Rok publikacji:
- 2024
- Data zatwierdzenia:
- 2024-10-11
- Data wytworzenia:
- 2024
- Język danych badawczych:
- angielski
- Dyscypliny:
-
- inżynieria chemiczna (Dziedzina nauk inżynieryjno-technicznych)
- DOI:
- Identyfikator DOI 10.34808/rn6j-x502 otwiera się w nowej karcie
- Weryfikacja:
- Zachodniopomorski Uniwersytet Technologiczny w Szczecinie
Słowa kluczowe
Cytuj jako
Autorzy
wyświetlono 64 razy