A rapid-response ultrasensitive biosensor for influenza virus detection using antibody modified boron-doped diamond - Publikacja - MOST Wiedzy

Wyszukiwarka

A rapid-response ultrasensitive biosensor for influenza virus detection using antibody modified boron-doped diamond

Abstrakt

According to the World Health Organization (WHO), almost 2 billion people each year are infected worldwide with flu-like pathogens including influenza. This is a contagious disease caused by viruses belonging to the family Orthomyxoviridae. Employee absenteeism caused by flu infection costs hundreds of millions of dollars every year. To successfully treat influenza virus infections, detection of the virus during the initial development phase of the infection is critical, when tens to hundreds of virus-associated molecules are present in the patient’s pharynx. In this study, we describe a novel universal diamond biosensor, which enables the specific detection of the virus at ultralow concentrations, even before any clinical symptoms arise. A diamond electrode is surface-functionalized with polyclonal anti-M1 antibodies, which then serve to identify the universal biomarker for the influenza virus, M1 protein. The absorption of the M1 protein onto anti-M1 sites of the electrode change its electrochemical impedance spectra. We achieved a limit of detection of 1 fg/ml in saliva buffer for the M1 biomarker, which corresponds to 5–10 viruses per sample in 5 minutes. Furthermore, the universality of the assay was confirmed by analyzing different strains of influenza A virus.

Cytowania

  • 1 0 7

    CrossRef

  • 0

    Web of Science

  • 1 0 5

    Scopus

Autorzy (12)

Cytuj jako

Pełna treść

pobierz publikację
pobrano 131 razy
Wersja publikacji
Accepted albo Published Version
Licencja
Creative Commons: CC-BY otwiera się w nowej karcie

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuł w czasopiśmie wyróżnionym w JCR
Opublikowano w:
Scientific Reports nr 7, strony 1 - 10,
ISSN: 2045-2322
Język:
angielski
Rok wydania:
2017
Opis bibliograficzny:
Nidzworski D., Katarzyna S., Niedziałkowski P., Bogdanowicz R., Sobaszek M., Ryl J., Weiher P., Sawczak M., Wnuk E., Goddard Iii W. A., Jaramillo-Botero A., Ossowski T.: A rapid-response ultrasensitive biosensor for influenza virus detection using antibody modified boron-doped diamond// Scientific Reports. -Vol. 7, iss. 1 (2017), s.1-10
DOI:
Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1038/s41598-017-15806-7
Weryfikacja:
Politechnika Gdańska

wyświetlono 268 razy

Publikacje, które mogą cię zainteresować

Meta Tagi