Application of micellar electrokinetic chromatography for detection of silver nanoparticles released from wound dressing - Publikacja - MOST Wiedzy

Wyszukiwarka

Application of micellar electrokinetic chromatography for detection of silver nanoparticles released from wound dressing

Abstrakt

The recent emergence of nanotechnology has provided a new therapeutic modality in case of silver nanoparticles. Dressings containing silver form the basis for the treatment of burns and wounds, either acute or chronic ones. The aim of the study was to examine silver release from the different wound dressings: commercially available (Atrauman Ag, Aqua- cel Ag) and experimental (FKDP-AgNPs) using MEKC. In order to characterize prepared keratin based wound dressing before and after its modification with AgNPs, a compo- sitional analysis was conducted using energy dispersive X-ray spectroscopy. Nanosilver toxicity was evaluated with the 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2- (4 sulfophenyl)-2H-tetrazolium test. Silver release from wound dressings was assessed using MEKC. The best separation was observed for MEKC in 20 mM borate buffer at pH 9 with 20 mM SDS addition. In vitro studies showed silver at higher concentration than 10 ppm exerted a toxic effect on fibroblasts isolated from diabetic mice versus. NIH/3T3 and BJ cell lines (p 0.05). We observed silver was released more gradually from ex- perimental FKDP-AgNPs wound dressing, in compare to commercially available wound dressings. The fast and low-cost method utilizing MEKC can be used in clinical practice to detect silver release from the wound dressings

Cytowania

  • 8

    CrossRef

  • 0

    Web of Science

  • 7

    Scopus

Autorzy (9)

Cytuj jako

Pełna treść

pełna treść publikacji nie jest dostępna w portalu

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuł w czasopiśmie wyróżnionym w JCR
Opublikowano w:
ELECTROPHORESIS strony 1565 - 1572,
ISSN: 0173-0835
Język:
angielski
Rok wydania:
2019
Opis bibliograficzny:
Konop M., Kłodzińska E., Borowiec J., Laskowska A., Czuwara J., Konieczka P., Cieślik B., Waraksa E., Rudnicak L.: Application of micellar electrokinetic chromatography for detection of silver nanoparticles released from wound dressing// ELECTROPHORESIS. -, iss. 40 (2019), s.1565-1572
DOI:
Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1002/elps.201900020
Weryfikacja:
Politechnika Gdańska

wyświetlono 166 razy

Publikacje, które mogą cię zainteresować

Meta Tagi