Dead time effects compensation strategy by third harmonic injection for a five-phase inverter - Publikacja - MOST Wiedzy

Wyszukiwarka

Dead time effects compensation strategy by third harmonic injection for a five-phase inverter

Abstrakt

This paper proposes a method for compensation of dead-time effects for a fivephase inverter. In the proposed method an additional control subsystem was added to the field-oriented control (FOC) scheme in the coordinate system mapped to the third harmonic. The additional control loop operates in the fixed, orthogonal reference frame ( α - β coordinates) without the need for additional Park transformations. The purpose of this method is to minimize the dead-time effects by third harmonic injection in two modes of operation of the FOC control system: with sinusoidal supply and with trapezoidal supply. The effectiveness of the proposed control method was verified experimentally on a laboratory setup with a prototype five-phase interior permanent magnet synchronous machine (IPMSM). All experimental results were presented and discussed in the following paper.

Cytowania

  • 0

    CrossRef

  • 0

    Web of Science

  • 0

    Scopus

Cytuj jako

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuły w czasopismach
Opublikowano w:
Archives of Electrical Engineering nr 73, strony 17 - 35,
ISSN: 1427-4221
Język:
angielski
Rok wydania:
2024
Opis bibliograficzny:
Łuksza K., Kondratenko D., Lewicki A.: Dead time effects compensation strategy by third harmonic injection for a five-phase inverter// Archives of Electrical Engineering -Vol. 73,iss. 1 (2024), s.17-35
DOI:
Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.24425/aee.2024.148854
Źródła finansowania:
Weryfikacja:
Politechnika Gdańska

wyświetlono 72 razy