Diagnostics of bolted lap joint using guided wave propagation - Publikacja - MOST Wiedzy

Wyszukiwarka

Diagnostics of bolted lap joint using guided wave propagation

Abstrakt

The paper presents numerical and experimental analyses of elastic waves propagation in a bolted lap joint. In experimental investigations condition assessment of the joint was performed with the use of symmetric waves excited by a piezoactuator. Numerical calculations were conducted in commercial finite element method software Abaqus. The influence of number of bolts and the value of the initial stress on recorded signals was examined. The study showed the possibility of using elastic waves in the context of diagnostics of bolted joints.

Cytuj jako

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuły w czasopismach recenzowanych i innych wydawnictwach ciągłych
Opublikowano w:
Diagnostyka nr 15, strony 35 - 40,
ISSN: 1641-6414
Język:
angielski
Rok wydania:
2014
Opis bibliograficzny:
Kędra R., Rucka M.: Diagnostics of bolted lap joint using guided wave propagation// Diagnostyka. -Vol. 15., iss. 4 (2014), s.35-40