Experimental tests of lintel hybrid beams - Publikacja - MOST Wiedzy

Wyszukiwarka

Experimental tests of lintel hybrid beams

Abstrakt

The results of experimental tests of lintel hybrid beams made of air concrete and prestressed concrete were presented in paper. Blocks of air concrete was a protective element for the construction one. The length of hybrid beams was 3.0 m, while total height 27 cm. It was assumed that hybrid beams will work in the simply-supported scheme (with a 10 cm support) loaded uniformly over the entire length. The object of the tests were beams with the same geometry differing in the position of the prestressed wire. In the first considered case the wire was located at a distance of 6.5 cm from the bottom edge of the construction part (prestressed concrete) of beam, while in the second case: 13 cm from the bottom edge of the construction part of beam. The experimental tests under static monotonous load up to the failure were examined. The paper shortly described the designing stage of project. Hybrid beams were calculated with Limit State Method and Allowable Stress Method. Some assumptions for element calculations were also presented.

Cytuj jako

Pełna treść

pełna treść publikacji nie jest dostępna w portalu

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Aktywność konferencyjna
Typ:
publikacja w wydawnictwie zbiorowym recenzowanym (także w materiałach konferencyjnych)
Język:
angielski
Rok wydania:
2019
Opis bibliograficzny:
Nagrodzka-Godycka K., Solarczyk M. T., Wesołowski M.: Experimental tests of lintel hybrid beams// / : , 2019,
Weryfikacja:
Politechnika Gdańska