Influence of nonlinearities on the efficiency and accuracy of FEM calculations on the example of a steel build-up thin-walled column
Abstrakt
Due to the increase of computing capabilities of standard processing units, it is possible to perform complex analyses, considering a number of nonlinearities, such as geometric, material and boundary (contact) even on personal computers. In the paper, the authors have analysed the efficiency and accuracy of standard PC’s FEM calculations performed in Abaqus CAE 2017 software on the example of a critical load assessment of a thin-walled steel column element with selected nonlinearities. A cross-section shape of a built-up column used by an international steel structures manufacturer was adopted. The analysis serves to check the behavior of their product. Several types of FEM analysis, strictly based on the EN standard regulations were performed. In turn, the relation of computational time to the adopted analysis type was obtained. Moreover, the produced load values in different types of independent calculation were compared and analysed. A possible future development in the field, based mainly on full-scale experimental tests, was also highlighted.
Cytowania
-
2
CrossRef
-
0
Web of Science
-
2
Scopus
Autorzy (2)
Cytuj jako
Pełna treść
- Wersja publikacji
- Accepted albo Published Version
- Licencja
-
otwiera się w nowej karcie
Słowa kluczowe
Informacje szczegółowe
- Kategoria:
- Publikacja w czasopiśmie
- Typ:
- artykuły w czasopismach
- Opublikowano w:
-
MATEC Web of Conferences
strony 1 - 8,
ISSN: 2261-236X - Język:
- polski
- Rok wydania:
- 2018
- Opis bibliograficzny:
- Deniziak P., Winkelmann K.: Influence of nonlinearities on the efficiency and accuracy of FEM calculations on the example of a steel build-up thin-walled column// MATEC Web of Conferences -, (2018), s.1-8
- DOI:
- Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1051/matecconf/201821902010
- Bibliografia: test
-
- M. Dabaon, E. Ellobody, K. Ramzy, Nonlinear behaviour of built-up cold-formed steel section battened columns, Journal of Constructional Steel Research, 110 (2015) otwiera się w nowej karcie
- Y. H. Lee, C. S. Tan, S. Mohammad, In-plane sway behaviour of slender cold-formed steel bolted frames, Thin-walled Structures, 114 (2017) otwiera się w nowej karcie
- K. Słowiński, W. Wuwer, Investigations of closely spaced build-up bars with flexible joints, The 6th International Conference on Thin Walled Structures (2011)
- R. Zaharia, D. Dubina, Stiffness of joints in bolted connected cold-formed steel trusses, Journal of Constructional Steel Research, 62 (2006) otwiera się w nowej karcie
- J. Zhang, B. Young, Numerical investigation and design of cold-formed steel built-up open section columns with longitudinal stiffeners, Thin-walled Structures, 89 (2015) otwiera się w nowej karcie
- M. Gordziej-Zagórowska, E. Urbańska-Galewska, Ł. Pyrzowski, The validation process of truss model with joint eccentricities, Shell Structures: Theory and Applications, 4 (to be published) otwiera się w nowej karcie
- P. Deniziak, K. Winkelmann, TS-based RSM-aided design of cold-formed steel stiffened C-sectional columns susceptible to buckling, Shell Structures: Theory and Applications, 4 (to be published) otwiera się w nowej karcie
- EN 1993-1-6, Eurocode 3 -Design of steel structures -Part 1-6: Strength and Stability of Shell Structures. otwiera się w nowej karcie
- M. Gordziej-Zagórowska, PhD thesis, Wpływ mimośrodów na nośność węzłów dźwigarów kratownicowych wykonanych z kształtowników giętych na zimno o przekrojach otwartych (2017) [in Polish]
- G. Watts, M.K. Singha, S. Pradyumna, Nonlinear bending and snap-through instability analyses of conical shell panels using element free Galerkin method, Thin-walled Structures, 122 (2018) otwiera się w nowej karcie
- P. Mika, Analiza MES zagadnień sprężysto-plastycznych -program Abaqus, 13 (2011) [in Polish]
- S. Selvaraj, M. Madhavan, Geometric imperfection measurements on cold-formed steel channels, Wiley Online Library (2017) otwiera się w nowej karcie
- Weryfikacja:
- Politechnika Gdańska
wyświetlono 88 razy