Abstrakt
We present the optical measurement techniques used in human skin phantom studies. Their accuracy and the sources of errors in microscopic parameters’ estimation of the produced phantoms are described. We have produced optical phantoms for the purpose of simulating human skin tissue at the wavelength of 930 nm. Optical coherence tomography was used to measure the thickness and surface roughness and to detect the internal inhomogeneities. A more detailed study of phantom surface roughness was carried out with the optical profilometer. Reflectance, transmittance, and collimated transmittance of phantoms were measured using an integrating-sphere spectrometer setup. The scattering and absorption coefficients were calculated with the inverse adding-doubling method. The reduced scattering coefficient at 930 nm was found to be 1.57 0.14 mm−1 and the absorption was 0.22 0.03 mm−1. The retrieved optical properties of phantoms are in agreement with the data found in the literature for real human tissues.
Cytowania
-
4 3
CrossRef
-
0
Web of Science
-
5 6
Scopus
Autorzy (6)
Cytuj jako
Pełna treść
- Wersja publikacji
- Accepted albo Published Version
- DOI:
- Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1117/1.JBO.20.4.045004
- Licencja
- otwiera się w nowej karcie
Słowa kluczowe
Informacje szczegółowe
- Kategoria:
- Publikacja w czasopiśmie
- Typ:
- artykuł w czasopiśmie wyróżnionym w JCR
- Opublikowano w:
-
JOURNAL OF BIOMEDICAL OPTICS
nr 20,
wydanie 4,
ISSN: 1083-3668 - Język:
- angielski
- Rok wydania:
- 2015
- Opis bibliograficzny:
- Wróbel M., Popov A., Bykov A., Kinnunen M., Jędrzejewska-Szczerska M., Tuchin V.: Measurements of fundamental properties of homogeneous tissue phantoms// JOURNAL OF BIOMEDICAL OPTICS. -Vol. 20, iss. 4 (2015),
- DOI:
- Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1117/1.jbo.20.4.045004
- Weryfikacja:
- Politechnika Gdańska
Powiązane datasety
- dane badawcze Optical Parameters Stability Over Time of Porous Phantoms Mimicking Tissues
- dane badawcze Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser.
- dane badawcze Measurement of the temperature change of PVCP tissue phantom illuminated by dermatological laser 1.series
wyświetlono 206 razy
Publikacje, które mogą cię zainteresować
Multi-layered tissue head phantoms for noninvasive optical diagnostics
- M. Wróbel,
- A. P. Popov,
- A. Bykov
- + 3 autorów
Nanoparticle-free tissue-mimicking phantoms with intrinsic scattering
- M. Wróbel,
- A. P. Popov,
- A. Bykov
- + 2 autorów