Sensitive method for determination of benzoic acid in beverages and food samples using air–assisted hydrophobic deep eutectic solvent-based dispersive liquid-liquid microextraction - Publikacja - MOST Wiedzy

Wyszukiwarka

Sensitive method for determination of benzoic acid in beverages and food samples using air–assisted hydrophobic deep eutectic solvent-based dispersive liquid-liquid microextraction

Abstrakt

A simple, reliable and rapid air–assisted hydrophobic deep eutectic solvent-based dispersive liquid–liquid microextraction (AA-HDES-DLLME) was developed for analysis of benzoic acid in various beverages and food samples. The final determination stage was performed via UV–visible spectrophotometry. The key parameters (extraction time, HDES type and volume, dispersant volume, pH and sample volume) of the AA-HDES-DLLME method were optimized in detailed using Box–Behnken design. Analysis of variance was used for statistical analysis. Under the optimized conditions, limit of detection (12.1 μg L−1), limit of quantification (40 μg L−1), linearity range (40–1000 μg L−1), and preconcentration factor (140) were determined. While the accuracy of the AA-HDES-DLLME method was investigated with the standard addition approach, its precision was investigated with intraday/interday studies. The method proved to be effective for routine analytical practice for a wide variety of samples. The novelty of the AA-HDES-DLLME method is that it enables the extraction of benzoic acid without the need for heating or centrifugation steps. In this way, the AA-HDES-DLLME method enabled selective extraction of benzoic acid in a shorter time and using less energy compared to similar studies.

Cytowania

  • 0

    CrossRef

  • 0

    Web of Science

  • 0

    Scopus

Cytuj jako

Pełna treść

pełna treść publikacji nie jest dostępna w portalu

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuły w czasopismach
Opublikowano w:
Sustainable Chemistry and Pharmacy nr 38,
ISSN: 2352-5541
Język:
angielski
Rok wydania:
2024
Opis bibliograficzny:
Haq H.: Sensitive method for determination of benzoic acid in beverages and food samples using air–assisted hydrophobic deep eutectic solvent-based dispersive liquid-liquid microextraction// -, (2024),
DOI:
Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1016/j.scp.2024.101464
Źródła finansowania:
  • COST_FREE
Weryfikacja:
Politechnika Gdańska

wyświetlono 15 razy

Publikacje, które mogą cię zainteresować

Meta Tagi