Stability Analysis of Shunt Active Power Filter with Predictive Closed-Loop Control of Supply Current - Publikacja - MOST Wiedzy

Wyszukiwarka

Stability Analysis of Shunt Active Power Filter with Predictive Closed-Loop Control of Supply Current

Abstrakt

This paper presents a shunt active power filter connected to the grid via an LCL coupling circuit with implemented closed‐loop control. The proposed control system allows selective harmonic currents compensation up to the 50th harmonic with the utilization of a model‐based predictive current controller. As the system is fully predictive, it provides high effectiveness of the harmonic reduction, which is proved by waveforms achieved in performed tests. On the other hand, the control system is prone to loss of stability. Therefore, the paper is focused on the stability analysis of the discussed control system with the additional outer control loop of the supply current with predictive control of this current. The conducted stability analysis encompasses the assessment of system stability as a function of the coupling circuit parameter identification accuracy, whose values are implemented in the current controller, as well as parameters such as the sampling frequency and proportional–integral (PI) controller coefficients. The obtained results show that the ranges of the LCL circuit parameter identification accuracy for which the system remains stable are relatively wide. However, the most effective compensation of the supply current distortion is achieved for the parameters identified correctly, and the greatest impact on the compensation quality has the value of L1 inductance.

Cytowania

  • 1 4

    CrossRef

  • 0

    Web of Science

  • 1 7

    Scopus

Cytuj jako

Pełna treść

pobierz publikację
pobrano 158 razy
Wersja publikacji
Accepted albo Published Version
Licencja
Creative Commons: CC-BY otwiera się w nowej karcie

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuły w czasopismach
Opublikowano w:
ENERGIES nr 14,
ISSN: 1996-1073
Język:
angielski
Rok wydania:
2021
Opis bibliograficzny:
Bielecka A., Wojciechowski D.: Stability Analysis of Shunt Active Power Filter with Predictive Closed-Loop Control of Supply Current// ENERGIES -Vol. 14,iss. 8 (2021), s.2208-
DOI:
Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.3390/en14082208
Weryfikacja:
Politechnika Gdańska

wyświetlono 159 razy