Abstrakt
The paper analyses the relationship between an increase of the inner diameter of tubes made of Manaurite XM cast steel and transformations occurring in their microstructure due to long-lasting operation in methane reformer. Examinations included metallographic analysis with light microscope (LM), scanning electron microscope (SEM) and microanalysis of the chemical composition of precipitates (EDX). It was indicated that there is a relationship between the microstructure degradation ratio, morphology of the precipitates and an increase of the inner diameter of the tubes.
Cytowania
-
1
CrossRef
-
0
Web of Science
-
0
Scopus
Autorzy (3)
Cytuj jako
Pełna treść
pobierz publikację
pobrano 44 razy
- Wersja publikacji
- Accepted albo Published Version
- DOI:
- Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1515/adms-2017-0029
- Licencja
- otwiera się w nowej karcie
Słowa kluczowe
Informacje szczegółowe
- Kategoria:
- Publikacja w czasopiśmie
- Typ:
- artykuły w czasopismach recenzowanych i innych wydawnictwach ciągłych
- Opublikowano w:
-
Advances in Materials Science
nr 18,
wydanie 2,
strony 27 - 36,
ISSN: 1730-2439 - Język:
- angielski
- Rok wydania:
- 2018
- Opis bibliograficzny:
- Łabanowski J., Jurkowski M., Landowski M.: The Effect of Long Term Service at Elevated Temperatures on Microstructure Degradation of Austenitic Reformer Tubes// Advances in Materials Science. -Vol. 18., iss. 2 (2018), s.27-36
- DOI:
- Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1515/adms-2017-0029
- Weryfikacja:
- Politechnika Gdańska
wyświetlono 136 razy
Publikacje, które mogą cię zainteresować
Investigation of the 0.4C-35Cr-45Ni-Nb Alloy after Service in High-Temperature Steam and Hydrocarbons Environment
- J. Orlikowski,
- M. Szociński,
- J. Zygmuntowicz
- + 3 autorów
2021