Filtry
wszystkich: 1030
wybranych: 836
-
Katalog
- Publikacje 836 wyników po odfiltrowaniu
- Czasopisma 10 wyników po odfiltrowaniu
- Konferencje 11 wyników po odfiltrowaniu
- Wydawnictwa 1 wyników po odfiltrowaniu
- Osoby 10 wyników po odfiltrowaniu
- Projekty 4 wyników po odfiltrowaniu
- Kursy Online 3 wyników po odfiltrowaniu
- Dane Badawcze 155 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: GAS SENSOR, AMPEROMETRIC SENSOR, SELECTIVITY, CROSS-SENSITIVITY
-
The computational methods in the development of a novel multianalyte calibration technique for potentiometric integrated sensors systems
PublikacjaIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in small volume samples. One of the key problems related to the preparation of potentiometric integrated sensors systems (PISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim...
-
UV Light-Modulated Fluctuation-Enhanced Gas Sensing by Layers of Graphene Flakes/TiO2 Nanoparticles
PublikacjaWe present experimental results of fluctuation-enhanced gas sensing by low-cost resistive sensors made of a mixture of graphene flakes and TiO2 nanoparticles. Both components are photocatalytic and activated by UV light. Two UV LEDs of different wavelengths (362 and 394 nm) were applied to modulate the gas sensing of the layers. Resistance noise was recorded at low frequencies, between 8 Hz and 10 kHz. The sensors’ response was...
-
Sensitivity analysis of a composite footbridge
PublikacjaThis work include an example of sensitivity analysis for the design of a composite footbridge. A sandwich structure is used, consisting two high-strength skins separated by a core material. The analysis was conducted for two numerical models. The first one is a simple, single-span beam of a composite cross-section (laminate and foam), with different Young’s modulus for each material. Calculations were made by means of a MATLAB-based...
-
Measurement method for capacitive sensors for microcontrollers based on a phase shifter
PublikacjaA complete measurement method dedicated to capacitive sensors has been developed. It includes the development of hardware (an analogue interface circuit for microcontrollers with built-in times/counters and analogue comparators) and software (a measurement procedure and a systematic error calibration (correction) algorithm which is based on a calibration dictionary). The interface circuit consists of a low-pass filter and a phase...
-
Doped Nanocrystalline Diamond Films as Reflective Layers for Fiber-Optic Sensors of Refractive Index of Liquids
PublikacjaThis paper reports the application of doped nanocrystalline diamond (NCD) films—nitrogen-doped NCD and boron-doped NCD—as reflective surfaces in an interferometric sensor of refractive index dedicated to the measurements of liquids. The sensor is constructed as a Fabry–Pérot interferometer, working in the reflective mode. The diamond films were deposited on silicon substrates by a microwave plasma enhanced chemical vapor deposition...
-
Detection of the Plant Pathogen Pseudomonas Syringae pv. Lachrymans on Antibody-Modified Gold Electrodes by Electrochemical Impedance Spectroscopy
PublikacjaThe present work describes an impedimetric immunosensor for Pseudomonas syringae pv. lachrymans (Psl) detection. This pathogen infects many crop species causing considerable yield losses, thus fast and cheap detection method is in high demand. In the assay, the gold disc electrode was modified with 4-aminothiophenol (4-ATP), glutaraldehyde (GA), and anti-Psl antibodies, and free-sites were blocked with bovine serum albumin (BSA)....
-
Energy requirements for methods improving gas detection by modulating physical properties of resistive gas sensors
PublikacjaAbstract. One of the most important disadvantage of resistive gas sensors is their limited gas selectivity. Therefore, various methods modulating their physical properties are used to improve gas detection. These methods are usually limited to temperature modulation or UV light irradiation for the layers exhibiting photocatalytic effect. These methods cause increased energy consumption. In our study we consider how much energy...
-
Determination of refractive index dispersion using fiber-optic low-coherence Fabry–Perot interferometer: implementation and validation
PublikacjaWe present the implementation and validation of low-coherence Fabry–Perot interferometer for refractive index dispersion measurements of liquids. A measurement system has been created with the use of four superluminescent diodes with different optical parameters, a fiber-optic coupler and an optical spectrum analyzer. The Fabry–Perot interferometer cavity has been formed by the fiber-optic end and mirror surfaces mounted on a micromechanical...
-
Asynchronous distributed state estimation for continuous-time stochastic processes
PublikacjaWe consider the problem of state estimation of a continuous-time stochastic process using an asynchronous distributed multi-sensor estimation system (ADES). In an ADES the state of a process of interest is estimated by a group of local estimators. Each local estimator based, for example, on a Kalman filter, performs single sensor filtration but also fusion of its local results and results from other (remote) processors to compute...
-
3D Sound Intensity Measurement Around Organ Pipes Using Acoustic Vector Sensors
PublikacjaThe aim of the presented paper was to obtain and visualize sound intensity distribution of radiated acoustic energy around the organ pipes. The experimental setup consisted of the multichannel acoustic vector sensor and the specialized Cartesian robot. Measurements were performed in free field with spatial resolution of 0.1 [m]. Two organ pipes, i.e. wooden and metal were measured during the ex-periment. The organ pipes were activated...
-
An extension to the FEEDB Multimodal Database of Facial Expressions and Emotions
PublikacjaFEEDB is a multimodal database that contains recordings of people expressing different emotions, captured by using a Microsoft Kinect sensor. Data were originally provided in the device’s proprietary format (XED), requiring both the Microsoft Kinect Studio application and a Kinect sensor attached to the system to use the files. In this paper, we present an extension of the database. For a selection of recordings, we also provide...
-
Facial emotion recognition using depth data
PublikacjaIn this paper an original approach is presented for facial expression and emotion recognition based only on depth channel from Microsoft Kinect sensor. The emotional user model contains nine emotions including the neutral one. The proposed recognition algorithm uses local movements detection within the face area in order to recognize actual facial expression. This approach has been validated on Facial Expressions and Emotions Database...
-
Electronic Noses in Medical Diagnostics
PublikacjaElectronic nose technology is being developed in order to identify aromas in a way parallel to the biologic olfaction. When applied to the field of medicine, such device should be able to identify and discriminate between different diseases. In recent years this kind of approach finds application in medical diagnostics, and especially in disease screening. Despite the fact that devices utilizing chemical sensor arrays are not routinely...
-
Fluctuation-Enhanced Sensing of Organic Vapors by Ink-Printed MoS2 Devices under UV Irradiation
PublikacjaThis work presents the results of fluctuationenhanced sensing (FES) of selected organic gases by MoS2 sensor fabricated via a simple ink printing method. We demonstrate that low-frequency noise measured under UV irradiation (275 nm) is more sensitive to different gases than measured in the dark. The noise at 1 Hz under UV light increased 3.3, 3.5, 1.6, and 2.9 times for chloroform, tetrahydrofuran, acetonitrile, and acetone ambiances, respectively....
-
Low energy elastic electron scattering from benzonitrile (C6H5CN)
PublikacjaWe present experimental differential elastic scattering cross sections (DCSs) for low energy electron scattering from benzonitrile along with integral and momentum-transfer cross sections that are determined from these DCSs. The measurements of DCSs are obtained using the relative flow method with helium as the standard gas, in a crossed electron-molecular gas beam arrangement. Our measurements are made at incident electron energies...
-
Radioisotope measurements of the liquid-gas flow in the horizontal pipeline using phase method
PublikacjaThe paper presents application of the gamma-absorption method to a two-phase liquid-gas flow investigation in a horizontal pipeline. The water-air mixture was examined by a set of two Am-241 radioactive sources and two NaI(Tl) scintillation probes. For analysis of the electrical signals obtained from detectors the cross-spectral density function (CSDF) was applied. Results of the gas phase average velocity measurements for CSDF...
-
Application of an Electronic Nose Instrument to Fast Classification of Polish Honey Types
PublikacjaThe paper presents practical utilization of an electronic nose prototype, based on the FIGARO semiconductor sensors, in fast classification of Polish honey types—acacia flower, linden flower, rape, buckwheat and honeydew ones. A set of thermostating modules of the prototype provided gradient temperature characteristics of barbotage-prepared gas mixtures and stable measurement conditions. Three chemometric data analysis methods...
-
Sensitivity analysis of flexural and torsional buckling loads of laminated columns
PublikacjaThe paper concerns first order sensitivity analysis of flexural and torsional bucklin g loads of axiallycompressed thin-walled columns with bisymmetric or axisymmetric cross-section made of unidirectional fibre-reinforcedlaminate. The first variation of critical loads versus some variations of the column material properties and cross-sectionaldimensions is derived. Numerical examples dealing with simply supported I-columns are...
-
Light box for investigation of characteristics of optoelectronics detectors
PublikacjaIn this paper, a light box for investigation of characteristics of optoelectronic detectors is described. The light box consists of an illumination device, an optical power sensor and a mechanical enclosure. The illumination device is based on four types of high-power light emitting diodes (LED): white light, red, green and blue. The illumination level can be varied for each LED independently by the driver and is measured by optical...
-
A novel calibration method for RSS-based DoA estimation using ESPAR antennas
PublikacjaIn this paper, we introduce a new calibration method that can successfully be used in direction of arrival (DoA) estimation using electronically steerable parasitic array radiator (ESPAR) antennas and employing power-pattern cross-correlation (PPCC) algorithm, which relies on received signal strength (RSS) values recorded at the antenna output port. Instead of the commonly used two-step approach, during which ESPAR antenna calibration...
-
Comparison of the Measurement Techniques Employed for Evaluation of Ambient Air Odour Quality Influenced by Operation of Industrial Sewage Treatment Plant
PublikacjaThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of a sewage treatment plant of the LOTOS Group S.A. petroleum plant. The investigation was performed during winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type...
-
Monitoring of odour nuisance in the Tricity Agglomeration
PublikacjaThe paper describes a principle of operation of odour nuisance monitoring network, which is being designed in the Tricity Agglomeration. Moreover, it presents the preliminary results of an investigation on ambient air quality with respect to odour nuisance in a vicinity of the municipal landfill. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The...
-
Comparison of the measurement techniques employed for evaluation of ambient air odour quality
PublikacjaThe paper presents the results of investigation on ambient air odour quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field...
-
Alternative methods for dark fermentation course analysis
PublikacjaDark fermentation course analysis is crucial, as complexed matrix of gaseous components may be formed and revealed during the process. The paper considers key issues related to the microbiological process in which complex organic substances are transformed into hydrogen. For the purposes of hydrogen generation, the application of wastewater mixed sludge pre-treated according to Faloye method (Faloye et al. in Int J Hydrog Energy...
-
A novel hierarchically-porous diamondized polyacrylonitrile sponge-like electrodes for acetaminophen electrochemical detection
PublikacjaA novel composite electrode material consisting of tangled fibrous polyacrylonitrile-based hierarchically-struc- tured nanocomposites has been produced by wet-spinning, carbonized and decorated with a carbon nano- architecture by microwave plasma-enhanced chemical vapor deposition and investigated as a metal-free electrode for the enhanced electrochemical detection of acetaminophen. Surprisingly, the hierarchical fiber ar- chitecture...
-
Tetrahedrally modified MnMe0.1Co1.9O4 (Me = Zn, Mg, Li) spinels for non-enzymatic glucose sensing
PublikacjaIn this work, tetrahedrally modified MnMe0.1Co1.9O4 (Me = Zn, Mg, Li) spinels were prepared via the sol–gel synthesis method with subsequent ball-milling fragmentation. The prepared samples were evaluated as glucose–sensing catalyst. The reference MnCo2O4 spinel exhibited a sensitivity of 49 µA mM−1 cm−2 and a nonlinearity error of 5.2% in the response range from 0.02 to 1 mM. The partial substitution of cobalt in the reference...
-
Guaranteeing Threshold Attendance of W/WSAN nodes in a reverted security paradigm
PublikacjaWe consider a Wireline/Wireless Sensor and Actor Network composed of sensor/actor nodes and a data sink/command center (DSCC). Each node controls a generic device that can be in- or out-of-service, corresponding to the ENABLED or DISABLED node state. The node senses the device's intention to change state, and notifies and/or requests the DSCC for authorization to act upon the device. Motivated by requirements for critical infrastructures...
-
Gdansk Bay sea bed sounding and classification of its results
PublikacjaThe main goal of this paper is to describe the results of sounding the Gdansk Bay sea bed by using a SES-2000 Standard parametric sub-bottom profiler. Quality of data obtained during trials depends inter alia on a proper location of transducer array to reduce influence of pitch, roll and heave motions as well as ship self noise (resulting from bubbles due to propeller and flow around hull, vibration generated by main engine and...
-
Fiber-optic Fabry-Pérot sensors – modeling versus measurements results
PublikacjaThis paper describes how parameters of investigated substances and the fiber-optic Fabry-Pérot sensing interferometer affect the spectrum of the optical radiation at the output of the sensor. First, the modeling of the operation of the sensing interferometer was conducted. Most important parameters and effects that were taken into account are: dependences of the refractive indices of the core and the cladding, as well the mode...
-
Selective monitoring of noise emitted by vehicles involved in road traffic
PublikacjaAn acoustic intensity probe was developed measures the sound intensity in three orthogonal directions, making possible to calculate the azimuth and elevation angles, describing the sound source position. The acoustic sensor is made in the form of a cube with a side of 10 mm, on the inner surfaces of which the digital MEMS microphones are mounted. The algorithm works in two stages. The first stage is based on the analysis of sound...
-
On instabilities and post-buckling of piezomagnetic and flexomagnetic nanostructures
PublikacjaWe focus on the mechanical strength of piezomagnetic beam-like nanosize sensors during post-buckling. An effective flexomagnetic property is also taken into account. The modelled sensor is selected to be a Euler-Bernoulli type beam. Long-range interactions between atoms result in a mathematical model based on the nonlocal strain gradient elasticity approach (NSGT). Due to possible large deformations within a post-buckling phenomenon,...
-
Permeation and sorption properties of poly(ether-block-amide) membranesfilled by two types of zeolites
PublikacjaThe experimental study of transport properties of mixed matrix membranes (MMMs) based on PEBA-4033 with two types of zeolites is reported. Gas (CO2, O2, N2) and vapor (benzene, toluene, methanol, water) permeation measurements were performed using the differential flow permeameter at temperature of 298.15 K and at atmospheric pressure. Gas/vapor permeation was monitored by measuring the changes of the thermal conductivity of carrier...
-
Determination of benzodiazepines and Z-hypnotic drugs in whole blood samples by GC–MS/MS: Method development, validation and application
PublikacjaBenzodiazepines (BZDs) and Z-drugs are widely used as anxiolytics, sedative hypnotics, anticonvulsants and muscle relaxants. “Designer benzodiazepines” (DBZDs) are a new psychoactive substance class consisting of benzodiazepine derivatives that are not allowed for medical use and are known for being used recreationally. From a toxicologist standpoint, the huge number of such substances implicate a necessity for developing fast...
-
Thin CVD diamond films - synthesis, properties, applications
PublikacjaThe basic model of diamond films growth, in the low pressure synthesis, deposition from the CVD gas phase, is the mixture of hydrocarbon gas in presence with activated hydrogen and its nucleation on the substrate as a result of pyrolysis reaction. It allows to cross the great energetic barrier between graphite and diamond. High pressure and temperature are replaced by change of electronic structure of atoms into gas precursors...
-
Analysis of exhaled breath for dengue disease detection by low-cost electronic nose system
PublikacjaThis paper presents a procedure and a set-up of an electronic nose system analyzing exhaled breath to detect the patients suffering from dengue – a mosquito-borne tropical disease. Low-power resistive gas sensors (MiCS-6814, TGS8100) were used to detect volatile organic compounds (VOCs) in the exhaled breath. The end-tidal phase of patients exhaled breath was collected with a BioVOCTM breath sampler. Two strategies were assessed...
-
Positron Scattering and Annihilation in Organic Molecules
PublikacjaIn this paper, we address the problem of connecting positron lifetimes in liquids with collision cross sections in gases. We present the analyses of annihilation lifetime spectra of positrons in the liquid benzene, c-hexane, n-hexane, methanol and ethanol and calculations of scattering cross sections of positrons with benzene and c-hexane in the gas phase.
-
Investigation of Weigh-in-Motion Measurement Accuracy on the Basis of Steering Axle Load Spectra
PublikacjaWeigh-in-motion systems are installed in pavements or on bridges to identify and reduce the number of overloaded vehicles and minimise their adverse eect on road infrastructure. Moreover, the collected trac data are used to obtain axle load characteristics, which are very useful in road infrastructure design. Practical application of data from weigh-in-motion has become more common recently, which calls for adequate attention to...
-
Acoustic imaging of selected areas of Gdansk Bay with the aid of parametric echosounder and side-scan sonar
PublikacjaThe article presents and analyses the data recorded during sounding of the Gdansk Bay seabed with the aid of a parametric echosounder and a side-scan sonar. The accuracy of seabed structure examination, as a condition for obtaining valuable results, requires correct configuration of echolocation devices and proper calibration of peripheral devices, such as the survey unit geographical position sensor – GPS, the navigation unit,...
-
Design of a Cellular Dual-Band Sticker Antenna for Thickness-Independent 3D-Printed Substrates
PublikacjaAdditive manufacturing technology provides high flexibility in designing custom enclosures for prototype devices such as nodes of distributed sensor networks. Although integration of components is desired from the perspective of sensor mobility, it might negatively affect the performance of radio-connectivity due to couplings between the antenna and system peripherals, as well as other unaccounted effects of the 3D printed enclosure....
-
Sensitivity analysis in design process of sandwich U-shaped composite footbridge
PublikacjaThe structure of the sandwich composite footbridge of a 14 metre span length and U-shaped cross-section was analysed. Sensitivity analysis was performed to support the design process of this innovative object. Linear discrete sensitivity analysis was performed by means of finite element method. The influence of vari-ation of several design variables i.e. thicknesses of inner and outer laminates on the mid-span deflection, as-sumed...
-
Impedance-based sensing of the interlayer adhesion loss in organic coating systems.
PublikacjaZmienne parametry środowiska takie jak: temperatura,wilgotność i promieniowanie UV powodują degradację własności ochronnych powłok organicznych. Stosując sensor w postaci elektrod wykonanych z prądoprzewodzącego tuszu umieszczonych pomiędzy warstwami zestawu oraz technikę spektroskopii impedancyjnej stwierdzono możliwość monitorowania utraty adhezji międzywarstwowej.
-
Optoelektroniczne sensory fluorescencyjne dla monitoringu zanieczyszczeń środowiska
Publikacjaw pracy zaproponowano i opisano optoelektroniczny fluorescencyjny sensor do pomiaru stężenia kobaltu w wodzie. opisano zasadę działania tego typu sensorów. zaproponowano konfigurację laboratoryjnego stanowiska pomiarowego i przeprowadzono dobór niektórych jego komponentów. przedstawiono także etapy dalszych prac badawczych nad konstrukcją sensora.
-
Simple Measurement Method for Resistive Sensors Based on ADCs of Microcontrollers
PublikacjaA new, complete measurement method for resistance measurement of resistive sensors for systems based on microcontrollers equipped with analog-to-digital converters (ADCs) is proposed. The interface circuit consists of only four resistors, including a resistive sensor and a reference resistor, connected directly to the microcontroller pins. It is activated only during measurements, which significantly reduces power consumption....
-
A Simple Neural Network for Collision Detection of Collaborative Robots
PublikacjaDue to the epidemic threat, more and more companies decide to automate their production lines. Given the lack of adequate security or space, in most cases, such companies cannot use classic production robots. The solution to this problem is the use of collaborative robots (cobots). However, the required equipment (force sensors) or alternative methods of detecting a threat to humans are usually quite expensive. The article presents...
-
СИСТЕМА КОНТРОЛЯ СОСТОЯНИЯ ИЗОЛЯЦИИ ЭЛЕКТРОПРИВОДОВ В СЕТЯХ С ГЛУХОЗАЗЕМЛЕННОЙ НЕЙТРАЛЬЮ (System of insulation status monitoring for electric drives in networks with a dead-earth neutral)
PublikacjaПредложен метод контроля изоляции частотно-регулируемых электроприводов в сетях с глухозаземленной нейтралью. Система контроля изоляции включается в момент остановки электропривода. Ключи инвертора коммутируются по специальному закону, и с помощью сигнала трансформатора тока, который изме- ряет ток во всех трех фазах привода одновременно, определяется ток утечки. Рассмотрена схема датчика тока утечки и приведены экспериментальные...
-
Investigation of poly(3,4-ethylenedioxythiophene) deposition method influence on properties of ion-selective electrodes based on bis(benzo-15-crown-5) derivatives
PublikacjaGlassy carbon electrodes modified by conductive polymers and membrane with derivatives of bis(benzo-15-crown-5) were tested as solid contact ion selective electrodes for K+ ions concentration determination. PEDOT with PSS, Cl- and ClO4- counter ions was electrochemically deposited onto glassy carbon substrates using four different electrochemical approaches (potentiostatic, galvanostatic, potentiodynamic and potentiostatic pulses)....
-
Compensation of magnetic disturbances caused by sensors in a differential magnetometric system
PublikacjaStudy of low magnetic fields necessitates the use of precision magnetometers working in a differential system. Minimization of this error is a substantial issue in the case of magnetometers working in a differential system on a mobile platform. The compensation method of heading error consists in taking measurements of changes in magnetic induction with the use of the tested magnetometer for various locations of the sensor in relation...
-
RECENT ADVANCES IN GRAPHENE APPLICATION FOR ELECTRONIC SENSING
PublikacjaThe great interest in graphene is caused by its potential for constructing various sensors exhibiting excellent parameters. The high carrier mobility and the unique band structure of graphene makes it promising especially in the field-effect transistors (GFET) applications. In this article, recent advances of the selected graphene-based sensor applications were presented and the possible directions for further investigations were...
-
Low-power device simulator for micro-energy measurement methods testing
PublikacjaThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Measurements of Two-phase Flows in Pipelines Using Radioisotopes and Statistical Signal Processing
PublikacjaThis paper presents an application of radiotracers and gamma absorption method in two-phase flow measurements in pipelines. Two different methods were implemented to analysis of acquired signals. Investigated methods are based on the cross-correlation function and the phase of the cross-spectral density distribution. The examples presented in the article illustrate the application of the radioisotopes to evaluation of liquid-gas...