Filtry
wszystkich: 4628
wybranych: 3338
-
Katalog
- Publikacje 3338 wyników po odfiltrowaniu
- Czasopisma 68 wyników po odfiltrowaniu
- Konferencje 7 wyników po odfiltrowaniu
- Osoby 47 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 21 wyników po odfiltrowaniu
- Dane Badawcze 1144 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: OPTICAL VELOCITY MEASUREMENT
-
Using A Particular Sampling Method for Impedance Measurement
PublikacjaThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Badawczo-rozwojowe laboratorium sieci optycznych wykorzystujące sprzęt ADVA Optical Networking
PublikacjaPrzedstawiono uwarunkowania i kierunki zmian w sieciach optycznych, a następnie wskazano na potrzebę posiadania laboratorium, w którym możliwe byłoby prowadzenie prac badawczo-rozwojowych oraz kształcenie. Przedstawiono koncepcję takiej sieci opartej na sprzęcie ADVA Optical Networking zrealizowaną w Katedrze Sieci Teleinformacyjnych Wydziału ETI PG. Opisano możliwości sprzętowo-funkcjonalne tego laboratorium oraz prowadzone prace...
-
Petrophysical analyses of rock construction materials from the Roman rural settlement in Podšilo bay on Rab island (NE Adriatic, Croatia)
PublikacjaThis article presents the results of petrophysical analyses of limestones and sandstones used for the construction of the wall structures of a Roman rural settlement located in Podšilo Bay on Rab Island (Croatia). An on-site analysis of the walls indicated the use of different lithotypes, which is an uncommon case in the area. So far, no petrophysical properties of the applied materials have been tested, and their provenance...
-
Optical Coherence Tomography for nanoparticles quantitative characterization
PublikacjaThe unique features of nanocomposite materials depend on the type and size of nanoparticles, as well as their placement in the composite matrices. Therefore the nanocomposites manufacturing process requires inline control over certain parameters of nanoparticles such as dispersion and concentration. Keeping track of nanoparticles parameters inside a matrix is currently a difficult task due to lack of a fast, reliable and cost effective...
-
Wpływ azotowania jarzeniowego i laserowego nadtapiania na odporność kawitacyjną stali X5CrNi18-10
PublikacjaNierdzewne stale austenityczne charakteryzują się doskonałą odpornością korozyjną, aczkolwiek niskimi właściwościami mechanicznymi. W wielu przypadkach ogranicza to ich eksploatację w warunkach przemysłowych. Ponadto, nierdzewne stale austenityczne są wrażliwe na korozję lokalną w obecności jonów halogenkowych. Technologie materiałowe, które dają potencjalne możliwości otrzymywania korzystnego wpływu na właściwości mechaniczne...
-
Emotion Monitoring – Verification of Physiological Characteristics Measurement Procedures
PublikacjaThis paper concerns measurement procedures on an emotion monitoring stand designed for tracking human emotions in the Human-Computer Interaction with physiological characteristics. The paper addresses the key problem of physiological measurements being disturbed by a motion typical for human-computer interaction such as keyboard typing or mouse movements. An original experiment...
-
Effects of subfilter velocity modelling on dispersed phase in LES of heated channel flow
PublikacjaA non-isothermal turbulent flow with the dispersed phase is modelled using the Large Eddy Simulation (LES) approach for fluid, one-way coupled with the equations of point-particle evolution. The channel is heated at both walls and isoflux boundary conditions are applied for fluid. Particle velocity and thermal statistics are computed. Of particular interest are the r.m.s. profiles and the probability density function of particle...
-
Uncertainty of the liquid mass flow measurement using the orifice plate
PublikacjaThe article presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. This subject is essential because of the widespread use of this type of flow meters. Not only the quantitative estimation but also the qualitative results of those measurements are important. To achieve these results the authors of the paper propose to use the theory of uncertainty. The article shows the analysis of the...
-
Analytical Study of Sliding Instability due to Velocity- and Temperature-Dependent Friction
PublikacjaThe instability of sliding causes deterioration of performance characteristics of tribosystems and is undesired. To predict its occurrence, the motion of a body of a one-degree-of-freedom system with friction is investigated about the steady sliding equilibrium position. The motion equation is formulated with the friction coefficient dependent on the sliding velocity and contact temperature changing due to transient heat conduction...
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublikacjaThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
The field–dependent interface recombination velocity for organic–inorganic heterojunction
PublikacjaWe have derived an analytical formula which describes the field–dependent interface recombination velocity for the boundary of two materials characterized by different permittivities. The interface recombination of charge carriers has been considered in the presence of image force Schottky barrier. We suggest that this effect may play an important role in the loss of current for organic–inorganic hybrid heterojunctions. It has...
-
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublikacjaThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
MONTE CARLO MODELING OF OPTICAL SENSOR FOR POST-OPERATIVE FREE FLAP MONITORING
PublikacjaAfter a preliminary study of the currently employed methods in vitality monitoring of the tissue flaps (TRAM, DIEP, SIEA), a usefulness of optical techniques is discussed. It seems that one of the most promising in monitoring tissue flaps blood flow is a near infrared spectrometry (NIRS). However, a special design of a measurement sensor has to be developed. First, basing on the literature study an optical “window” is characterized....
-
5G/6G optical fronthaul modeling: cost and energy consumption assessment
PublikacjaIn fifth generation (5G) and the future beyond 5G (6G) radio access networks (RANs), the cost of fronthaul deployment is a main challenge for mobile network operators. Depending on different constraints, there are various solutions to deploy an efficient fronthaul. Fiber-optic-based fronthaul offers long-term support with regard to a rapid increase in capacity demands. When fiber connections, either point-to-point (P2P) or point-to-multipoint...
-
Measurement Campaign and Mathematical Model Construction for the Ship Zodiak Magnetic Signature Reproduction
PublikacjaThe paper presents the partial work done within the framework of the EDA Siramis II project focused on magnetic signature reproduction of ships. Reproduction is understood here as the ability to determine the magnetic anomaly of the local Earth magnetic field in any direction and at any measurement depth due to the presence of the analysed object. The B-91 type hydrographic ship Zodiak was selected as the real case study. The work...
-
Comparison of the tests for equivalence of the measurement methods for measurement of PM10 dust in ambient air
PublikacjaThe paper presents the motives for conducting the equivalence tests and the reasons of discrepancies between the results of PM10 dust concentration obtained via the reference method and the methods based on 'on-site' measurement. The reference and non-reference methods of measurement of PM10 dust concentration in air have been discussed. Field tests for equivalence, following the Polish standard and the European Union (EU) guidelines,...
-
Gold nanoparticles evaluation using functional optical coherence tomography
PublikacjaThe main object of this research was to assess the ability to characterize the gold nanoparticles using optical modalities like optical coherence tomography. Since the nanoparticles, especially gold one, have been very attractive for medical diagnosis and treatment the amount of research activities have been growing rapidly. The nanoparticles designed for different applications like contrast agents or drugs delivery change the...
-
Study on Combined Optical and Electrochemical Analysis Using Indium-tin-oxide-coated Optical Fiber Sensor
PublikacjaThe growing needs for fast and reliable sensing devices stimulate development of new technological solutions. In this work a new multi-domain sensing method is demonstrated where optical sensing device has been applied to enhance amount of data received during electrochemical analysis. Thin, optically transparent, high-refractive-index, and electrically conductive indium tin oxide (ITO) film was deposited using magnetron sputtering...
-
Optical and electrical properties of ultrathin transparent nanocrystalline boron-doped diamond electrodes
PublikacjaThe optical properties of ultrathin (less than 100 nm) boron-doped nanocrystalline diamond (B-NCD) film were investigated in a wavelength range of 200 ÷ 20000 nm. The B-NCD refractive index showed values close to that of monocrystalline diamond (n = 2.45) in a broad wavelength range (450 ÷ 4000 nm). A transmittance up to 70% and the average film thickness of 70 nm were achieved. A special cone-shaped shim was used in the deposition...
-
High-Resolution, Broad-Range Detection Setup for Polarimetric Optical Fiber Sensors
PublikacjaA common-path polarization interferometer using a Wollaston prism and an area detector for the measurement of retardation or optical path difference is presented. Employing a moderate-resolution 1280 by 1024 pixel monochrome camera, it offers a measurement range of approximately 780 radians at 830 nm and 1350 radians at 515 nm while maintaining a high measurement resolution. Retardation introduced by a zero-order waveplate or a...
-
Porous Phantoms Mimicking Tissues – Investigation of Optical Parameter Stability Over Time
PublikacjaIn terms of optical parameters, optical phantoms can now replace live tissues and be used to validate optical measurement methods. Therefore, whether these parameters would be maintained after storage for 6 months was examined. The absorption and scattering coefficients were obtained from the measured transmittance and reflectance measurements taken 6 months apart and then compared. All of the measurements were conducted using...
-
Porous Phantoms Mimicking Tissues—Investigation of Optical Parameters Stability Over Time
PublikacjaOptical phantoms are used to validate optical measurement methods. The stability of their optical parameters over time allows them to be used and stored over long-term periods, while maintaining their optical parameters. The aim of the presented research was to investigate the stability of fabricated porous phantoms, which can be used as a lung phantom in optical system. Measurements were performed in multiple series with an interval...
-
Surface quality control of a thin SiN layer by optical measurements
PublikacjaFiber optic interferometers have a wide range of applications, including biological and chemical measurements. Nevertheless, in the case of a reflective interferometer setup, standard silver mirrors cannot be used in every measurement, due to their chemical activity. This work investigates the surface quality of a thin optical layer of silicon nitride (SiN), which can serve as an alternative material for silver mirrors. We present...
-
A High-Efficient Measurement System With Optimization Feature for Prototype CMOS Image Sensors
PublikacjaIn this paper, a gray-scale CMOS image sensor (CIS) characterization system with an optimization feature has been proposed. By using a very fast and precise control of light intensity, based on the pulsewidth-modulation method, it is avoided to measure the illuminance every time. These features accelerate the multicriteria CIS optimization requiring many thousands of measurements. The system throughput is 2.5 Gb/s, which allows...
-
Optical Detection of Ketoprofen by Its Electropolymerization on an Indium Tin Oxide-Coated Optical Fiber Probe
PublikacjaIn this work an application of optical fiber sensors for real-time optical monitoring of electrochemical deposition of ketoprofen during its anodic oxidation is discussed. The sensors were fabricated by reactive magnetron sputtering of indium tin oxide (ITO) on a 2.5 cm-long core of polymer-clad silica fibers. ITO tuned in optical properties and thickness allows for achieving a lossy-mode resonance (LMR) phenomenon and it can be...
-
Annealing of indium tin oxide (ITO) coated optical fibers for optical and electrochemical sensing purposes
PublikacjaGlass and fiber structures with Indium Tin Oxide (ITO) coating were subjected to annealing in order to identify impact of the thermal treatment on their optical and electrochemical properties. It is shown that the annealing process significantly modifies optical properties and thickness of the films, which are crucial for performance of optical fiber sensors. Moreover, it visibly improves electrochemical activity of ITO on glass...
-
Measurement of temperature at sliding polymer surface by grindable thermocouples
PublikacjaThis paper is devoted to experimental study of capabilities and limitations of grindable thermocouples as applied to polymer materials sliding on metal. Chromel–alumel and chromel–copel grindable thermocouples have been developed and tested for wide ranges of contact pressure and sliding velocity. The background temperature of the sliding surface can be determined as the lower envelope of the signal from the grindable thermocouple....
-
Time-frequency analysis in optical coherence tomography for technical objects examination
PublikacjaOptical coherence tomography (OCT) is one of the most advanced optical measurement techniques for complex structure visualization. The advantages of OCT have been used for surface and subsurface defect detection in composite materials, polymers, ceramics, non-metallic protective coatings, and many more. Our research activity has been focused on timefrequency spectroscopic analysis in OCT. It is based on time resolved spectral analysis...
-
In-situ optical diagnostics of boron-doped diamond films growth
PublikacjaInterferometry is a desirable method for in-situ measurement of thin, dielectric film growth, as it don't modify conditions of film deposition. Here we present interferometrical measurements of thickness of doped diamond films during Chemical Vapor Deposition (CVD) process. For this purpose we used a semiconductor laser with a 405nm wavelength. Additional ex-situ measurement using spectral interferometry and ellipsometry...
-
Laser-textured cross-hatched surface topography analysis with evaluation of high-frequency measurement noise
PublikacjaThe precision of surface roughness determination using ISO 25178 parameters relies on various factors that directly impact the measurement process. In industry applications, the contactless roughness measurement reduces data collection time. However, it introduces several potential errors, including those stemming from the environment. One of the main types of errors encountered during topography analysis is measurement noise,...
-
Linking optical and electronic properties to photoresponse of heterojunctions based on titania nanotubes and chromium, molybdenum, and tungsten oxides
PublikacjaThe development of photosensitization strategies for titanium dioxide is necessary for the enhancement of its optical and electronic properties towards its application potential in solar photoelectrochemistry. In this work, significant differences in the photosensitizing capability of the 6th group transition metal oxides applied on the surface of titania nanotubes are reported. For the first time, correlations between the experimentally...
-
Topological extraordinary optical transmission
PublikacjaΤhe incumbent technology for bringing light to the nanoscale, the near-field scanning optical microscope, has notoriously small throughput efficiencies of the order of 10^4-10^5 or less. We report on a broadband, topological, unidirectionally guiding structure, not requiring adiabatic tapering and, in principle, enabling near-perfect (∼100%) optical transmission through an unstructured single arbitrarily subdiffraction slit at...
-
Nanocrystalline CVD Diamond Coatings on Fused Silica Optical Fibres: Optical Properties Study
Publikacjapre-treatment by dip coating in two detonation nanodiamond (DND) seeding media has been studied. The DND suspension in ethyl alcohol and dispersion of DND in dimethyl sulfoxide (DMSO) with polyvinyl alcohol (PVA) were chosen for the seeding purpose. The grain size distribution of nanodiamond particles in both seeding media was kept at the same level (approximately 1050 nm). After the seeding nanocrystalline diamond lms were deposited...
-
Optical monitoring of electrochemical processes with ITO-based lossy-mode resonance optical fiber sensor applied as an electrode
PublikacjaIn this work we discuss the application of optical fiber sensors based on lossy-mode resonance (LMR) phenomenon for real-time optical monitoring of electrochemical processes. The sensors were obtained by a reactive high power impulse magnetron sputtering of indium tin oxide (ITO) on a 2.5 cm-long core of polymer-clad silica fibers. The LMR effect made monitoring of changes in optical properties of both ITO and its surrounding medium...
-
Fluid–solid interaction on a thin platelet with high-velocity flow: vibration modelling and experiment
PublikacjaThe paper concerns the nonlinear behaviour of a thin platelet that is streamlined in an aerodynamic tunnel. The air velocity in the aerodynamic tunnel was at 858.9 km/h or 0.7 Ma (Ma—Mach number is a dimensionless quantity in fluid dynamics representing the ratio of flow velocity past a boundary to the local speed of sound). This experiment was numerically simulated using FSI (fluid–solid interaction) tools, namely the coupling...
-
Full scattering profile of circular optical phantoms mimicking biological tissue
PublikacjaHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. In our poster, we suggest a new type of skin phantom and an optical method for sensing physiological tissue condition, basing on the collection of the ejected light at all exit angles, to receive the full scattering profile. Conducted experiments were carried out on an unique set-up for noninvasive encircled measurement. Set-up consisted...
-
The influence of small amount of substances present in tissue on the optical spectrum of immunosuppressive drug
PublikacjaIn this paper, we describe how commonly present in tissue substances - sodium chloride and glucose - affect the optical spectrum of an immunosuppressive drug (Cyclaid® by Apotex). Prepared samples were investigated using the spectrophotometer in the spectrum range from 250 nm to 1100 nm. The maximum wavelength shift calculated on the basis of measurement results is not bigger than the measurement wavelength step. So, it can be...
-
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublikacjaA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
Advanced polarization sensitive analysis in optical coherence tomography
PublikacjaThe optical coherence tomography (OCT) is an optical imaging method, which is widely applied in variety applications. This technology is used to cross-sectional or surface imaging with high resolution in non-contact and non-destructive way. OCT is very useful in medical applications like ophthalmology, dermatology or dentistry, as well as beyond biomedical fields like stress mapping in polymers or protective coatings defects detection....
-
Application of gamma densitometry and statistical signal analysis to gas phase velocity measurements in pipeline hydrotransport
PublikacjaThe work presents selected methods of signal analysis used in the processing of data obtained from radiometric probes. The used data came from an exemplary study of a two-phase liquid-gas flow at the laboratory installation. In such rigs many possible transport types may be observed, i.e. slug, plug and bubble flow, and each of them gives different signal-to-noise ratio of recorded data. Therefore, available radiometric methods...
-
Application of gamma densitometry and statistical signal analysis to gas phase velocity measurements in pipeline hydrotransport
PublikacjaThe work presents selected methods of signal analysis used in the processing of data obtained from radiometric probes. The used data came from an exemplary study of a two-phase liquid-gas flow at the laboratory installation. In such rigs many possible transport types may be observed, i.e. slug, plug and bubble flow, and each of them gives different signal-to-noise ratio of recorded data. Therefore, available radiometric methods...
-
Label‐free optical detection of cyclosporine in biological fluids
PublikacjaIn this paper, a spectroscopic method for determination of cyclosporine concentrations in biological fluids is presented. Blood plasma and hemoglobin solutions are chosen for the experiment. For various cyclosporine concentrations in blood plasma and hemoglobin, absorbance measurements in spectra range from 600 to 1100 nm are performed. The measurement results are analyzed by the use of a dedicated algorithm. The obtained data...
-
A measurement system for children endurance tests
PublikacjaThere are a lot of ethical problems concerning the use of invasive methods for the measurement of a child's body response to physical exercise and physical training. The alternative is are non-invasive methods like ergospirometry or NIRS. The article presents a measurement system dedicated for children endurance tests, composed of a few non-invasive measurement modules, including a temperature measurement module. Temperature is...
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublikacjaAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
Protection in elastic optical networks
PublikacjaIn this article, we analyze gains resulting from the use of EON architectures with special focus on transportation of cloud-ready and content-oriented traffic in the context of network resilience. EONs are a promising approach for future optical transport networks and, apart from improving the network spectral efficiency, bring such new capabilities as squeezed protection, which reduces resource requirements in failure scenarios....
-
Radioisotope measurement of selected parameters of liquid-gas flow using single detector system
PublikacjaTo determine the parameters of two-phase flows using radioisotopes, usually two detectors are used. Knowing the distance between them, the velocity of the dispersed phase is calculated based on time delay estimation. Such a measurement system requires the use of two gamma-ray sealed sources. But in some situations it is also possible to determine velocity of dispersed phase using only one scintillation probe and one gamma-ray source....
-
Dual-wavelength polarimeter application in investigations of the optical activity of a langasite crystal
PublikacjaA method of high accuracy polarimetry, which includes optical activity measurements systematic errors, was realized with dual-wavelength polarimeter for two wavelengths of 635 and 650 nm. Simultaneous measurements with neighboring wavelengths significantly improved the data processing, by increasing the amount of data to eliminate the systematic errors. For langasite crystal La3Ga5SiO14 we measured temperature dependence of the...
-
Uncertainty of mass flow measurement using centric and eccentric orifice for Reynolds number in the range 10,000 ≤ Re ≤ 20,000
PublikacjaThe article analyses the impact of the Reynolds number on the estimated uncertainty of the mass flow rate measurement using an orifice plate. The objects of the research were two types of orifices: centric (ISA) and eccentric, with the diameter ratio β = 0.5. Studies were performed by Monte Carlo simulation and experiments for Reynolds numbers in the range 10,000 ≤ Re ≤ 20,000. The obtained results have shown that for both orifice...
-
Measurements of electron drift velocity in OCS
PublikacjaWykonano pomiary prędkości dryfu elektronów w funkcji zredukowanego pola elektrycznego E/N. Wyniki tych pomiarów porównano z wynikami pomiarów w CO2 i N2O.
-
Autonomus hydroacoustics sound velocity profiler.
PublikacjaPraca zawiera opis bezpośredniej zasady pomiarowej i struktury wersji autonomicznego miernika pomiarów rozkładów prędkości dźwięku w akwenach przeznaczonych do stosowania na okrętach nawodnych, podwodnych i opuszczanych antenach sonarowych śmigłowców i okrętów nawodnych.