Filtry
wszystkich: 3694
wybranych: 2881
-
Katalog
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: counter-current chromatography
-
Application of gas chromatography to the analysis of spirit-based alcoholic beverages
PublikacjaSpirit-based beverages are alcoholic drinks, which production processes are dependent on the type and origin of raw materials. The composition of this complex matrix is difficult to analyze and scientists commonly choose a gas chromatography techniques for this reason. With a wide selection of extraction methods and detectors it is possible to provide qualitative and quantitative analysis for many chemical compounds with a various...
-
Evaluation of flavour profiles in e-cigarette refill solutions using gas chromatography–tandem mass spectrometry
PublikacjaMany flavour compounds that are present in e-liquids for e-cigarettes are responsible for specific tastes and smoking sensations for users. Data concerning content and specific types of flavours is often limited and unknown to users. The aim of the research was to define and compare flavour profiles of e-liquids with the same group taste from different manufacturers. Gas chromatography coupled with tandem mass spectrometry (GC–MS/MS)...
-
Development of a liquid chromatography–tandem mass spectrometryprocedure for determination of endocrine disrupting compounds infish from Mediterranean rivers
PublikacjaA new, sensitive and rapid method based on QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe)approach followed by ultra high performance liquid chromatography coupled with tandem mass spec-trometry (UHPLC–MS/MS) was developed for the determination of nineteen endocrine disruptors (EDCs)and related compounds belonging to different classes in various fish species. Matrix effect on the analyti-cal performance was evaluated,...
-
Tripping limitations of residual current devices in photovoltaic installations
PublikacjaIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...
-
Current Issues in Pharmaceutical Residues in Drinking Water
Publikacja -
APPLICATION OF ULTRAFAST GAS CHROMATOGRAPHY TO RECOGNIZE ODOR NUISANCE
PublikacjaPotentialities of ultrafast gas chromatography applied to periodical monitoring of odor nuisance originating from a municipal landfill have been examined. The results of investigation on classification of the atmospheric air samples collected in a vicinity of the landfill during winter and summer season have been presented. The investigation was performed using ultrafast gas chromatography of Fast/Flash GC type HERACLES II by Alpha...
-
pH gradient high-performance liquid chromatography: theory and applications
Publikacja -
IMPACT OF DIRECT CURRENT ON NITRIFYING BIOMASS
PublikacjaEffects of short term exposure of nitrifying biomass to direct current were studied. DC was applied to mixed liquor from municipal BNR plant using graphite electrodes in no substrate limiting conditions. Both, ammonia oxidizing bacteria (AOB) and nitrite oxidizing bacteria (NOB) populations were affected by the current, however in opposite ways. The AOB population activity was inhibited by applied voltage. Activity decrease was...
-
Novel stationary phases based on asphaltenes for gas chromatography
PublikacjaWe present the results of investigations on the possibility of the application of the asphaltene fraction isolated from the oxidized residue from vacuum distillation of crude oil as a stationary phase for gas chromatography. The results of the investigation revealed that the asphaltene stationary phases can find use for the separation of a wide range of volatile organic compounds. The experimental values of Rohrschneider/McReynolds...
-
Low-frequency tripping characteristics of residual current devices
PublikacjaFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Comparison of an Electronic Nose Based on Ultrafast Gas Chromatography, Comprehensive Two-Dimensional Gas Chromatography, and Sensory Evaluation for an Analysis of Type of Whisky
PublikacjaWhisky is one of the most popular alcoholic beverages. There are many types of whisky, for example, Scotch, Irish, and American whisky (called bourbon). The whisky market is highly diversified, and, because of this, it is important to have a method which would enable rapid quality evaluation and authentication of the type of whisky. The aim of this work was to compare 3 methods: an electronic nose based on the technology of ultrafast...
-
Determination of Selected Organic Acids in Animal Farm Water Samples by Ion Chromatography
PublikacjaLow molecular mass carboxylic acids (LCAs) occur in many environmental compartments due to natural processes and human activity. They are an important group of organic pollutants of waste water that mainly includes, volatile fatty acids, and also dicarboxylic, aromatic, hydroxy- and ketoacids. LCAs are present in the environment at concentrations between 1 to 5000 ppm and different methods have been reported for their determination...
-
Current Source Inverter Fed Drive
PublikacjaThis book covers three-phase and multiphase (more than three-phase) motor drives including their control and practical problems faced in the field (e.g., adding LC filters in the output of a feeding converter), are considered. The new edition contains links to Matlab®/Simulink models and PowerPoint slides ideal for teaching and understanding the material contained within the book. Readers will also benefit from the inclusion of: A...
-
Residual current devices in installations with PV energy sources
PublikacjaThe paper presents the principles of residual current devices (RCDs) application in photovoltaic (PV) installations. Provisions of standards in this regard are commented on, in particular, attention is drawn to the lack of obligation to use of RCDs in PV installations. The issue of the shape of the earth fault current and the level of leakage currents in such installations are discussed. These factors influence the selection of...
-
Protection of bridges against stray current corrosion
PublikacjaA case study of Siennicki Bridge stray current corrosion hazard is presented. A corrosion risk was caused by incorrectly designed tram line traction which goes over the bridge. No dielectric insulation between running rails and bridge steel construction was used. A variety of protection methods against stray currents are described. Characteristics of the endangered bridge were described. Impressed current cathodic protection system...
-
Two-Dimensional Gas Chromatography Coupled With Mass Spectrometry in Food Analysis
PublikacjaThe development of instrumental analytical techniques provided the opportunity for in-depth characterization of many food matrices. In particular, the use of gas chromatography coupled with mass spectrometry gives impressive results in terms of quality and authenticity testing, conducting food freshness evaluations and contamination assessments. A new variant of gas chromatography, namely two-dimensional gas chromatography (GC...
-
Size-exclusion chromatography for the determination of the boiling point distribution of high-boiling petroleum fractions
PublikacjaThe paper describes a new procedure for the determination of boiling point distribution of high-boiling petroleum fractions using size exclusion chromatography with refractive index detector. Thus far, the determination of boiling range distribution by chromatography has been accomplished using simulated distillation with gas chromatography with the flame ionization detection. This study revealed that in spite of substantial differences...
-
Comprehensive determination of flavouring additives and nicotine in e-cigarette refill solutions. Part I: Liquid chromatography-tandem mass spectrometry analysis
PublikacjaLiquid chromatography-tandem mass spectrometry with electrospray ionization (HPLC-ESI–MS/MS) methods were developed for the simultaneous determination of 42 flavouring compounds and nicotine in liquids for e-cigarettes. The chromatographic separation was performed using an Ace® Ultracore™ SuperC18™ (100 × 2.1 mm, 2.5 μm) column in both acidic and alkaline pH conditions to separate all the compounds. A simple “dilute & shoot” approach...
-
Low Current Transformer Utilizing Co-Based Amorphous Alloys
PublikacjaMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Low current transformer utilizing Co-based amorphous alloys
PublikacjaMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Residual current devices in electric vehicles charging installations
PublikacjaThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...
-
Capillary gas chromatography using a -cyclodextrin forenantiomeric separation of methylamphetamine, its precursors andchloro intermediates after optimization of the derivatization reaction
PublikacjatThe enantiomeric ratio of methylamphetamine (MAMP) is closely related to the optical activity of precur-sors and reagents used for the synthesis and this knowledge can provide useful information concerningthe origins and synthetic methods used for illicit manufacture. The information can be utilized for reg-ulation of the precursors and investigation of the manufacturing sources but this requires analyticalprocedures to determine...
-
Method for the determination of carboxylic acids in industrial effluents using dispersive liquid-liquid microextraction with injection port derivatization gas chromatography–mass spectrometry
PublikacjaThe paper presents a new method for the determination of 15 carboxylic acids in samples of postoxidative effluents from the production of petroleum bitumens using ion-pair dispersive liquid-liquid microextraction and gas chromatography coupled to mass spectrometry with injection port derivatization. Several parameters related to the extraction and derivatization efficiency were optimized. Under optimized experimental conditions,the...
-
3D scanning system for railway current collector contact strips
PublikacjaUndisturbed collection of current from a contact wire of the catenary constitutes one of the basic elements in reliable operation of electrified rail transport, particularly when vehicles move at high speed. Quality of current collection is influenced by the construction of catenary and current collectors, as well as by the technical condition and regulation of these two elements. Total contact force of a current collector head...
-
Monitoring of absorptive model biogas purification process using sensor matrices and gas chromatography
PublikacjaThis study examined the process of purifying model biogas using a new type of absorbent based on a Deep Eutectic Solvent (DES) and a commercially available absorbent (Genosorb) to remove acetone, toluene, and cyclohexane. The main aim of the research was to control the purification efficiency using gas chromatography (GC) and an alternative method based on sensor matrices (SM). As a result of comparing the multidimensional SM signals...
-
First deep eutectic solvent-based (DES) stationary phase for gas chromatography and future perspectives for DES application in separation techniques
PublikacjaThe paper presents the first application of deep eutectic solvents (DES) as stationary phases for gas chromatography. DES obtained by mixing tetrabutylammonium chloride (TBAC) as a hydrogen bond acceptor (HBA) with heptadecanoic acid being a hydrogen bond donor (HBD) in a mole ratio of HBA:HBD equal to 1:2 was characterized by its ability to separate volatile organic compounds (VOCs). The Rohrschneider – McReynolds constants determined...
-
Technical diagnostics and monitoring of traction current collectors
PublikacjaNew evaluation methods of the technical condition of rolling stock current collectors are proposed in this paper. The method of automatic measurement of the pantograph static force characteristic, realized when the vehicle runs through the test section of the track with especially prepared overhead line height distribution, has been practically implemented by the Polish Railways. The method of testing the slipper spring suspension...
-
Indirect Measurement of Motor Current Derivatives in PMSM Sensorless Drives
PublikacjaMotor current derivatives contain useful information for control algorithms, especially in sensorless electric drives. The measurement of motor current derivatives in electric motors supplied by voltage source inverter can be performed using di/dt transducers. However, in such a solution additional sensors have to be installed, e.g. Rogowski coils. Another approach is to measure current derivatives indirectly – by oversampling...
-
Remarks on the Subject of Back-Up Protection of Residual Current Devices
PublikacjaResidual current devices without integral overcurrent protection (RCCBs) are back-up protected by fuses or miniature circuit-breakers (MCBs). If the latter are used, special attention must be given to the coordination between an RCCB and an MCB. This paper indicates probable cases of the aforementioned devices coordination, in which back-up protection of the RCCB is not adequate. A laboratory test has shown that depending on the...
-
Application of gas chromatography to evaluate the quality of rapeseed oil
PublikacjaTwo-dimensional gas chromatography is an analytical technique, which is increasingly being used in food research. Through the analysis of volatile fraction, it is possible to determine the quality of food products. One of the reasons for the deterioration of food is thermal degradation. Products that are often subject to degradation reactions due to temperatures are edible oils. In the thesis, the results of edible oils with different...
-
Chemometric optimization of derivatization reactions prior to gas chromatography–mass spectrometry analysis
Publikacja -
Visual measurement system for chosen parameters of current collectors
PublikacjaA current collector is an element in a traction vehicle, used for movable, contact con-nection between the main circuit of this vehicle and the contact line. Bad technical condi-tion of these important elements in the main circuit of the vehicle result in its incorrect cooperation with contact line. Periodic control of technical condition of current collectors ensures infallible current collection. The pantograph diagnostics consists...
-
Determining the leakage current resistive component by the orthogonal vector method
PublikacjaThe measurement of the metal – oxide surge arresters (MOSA) leakage current and the analysis of its components is a key diagnostic criterion according to technical standards. During on site MOSA condition assessment, the easy way is based on the measurement only leakage current, without the inconvenient live working measurements of supply voltage. Orthogonal vectors method of determination the resistive leakage current is presented....
-
Meat freshness classification using ultra-fast gas chromatography
PublikacjaMeat constitutes an important component of human diet. In order to ensure that it is safe to consume, it is important to be able to determine whether a particular sample is fresh. To this end, an analysis of the headspace of pork, beef, and poultrywas performed over a period of seven days using ultra-fast gas chromatography. Compounds that may possibly be used as indicators of spoilage were identified. Based on the obtained results...
-
Errors of a Linear Current Approximation in High-Speed PMSM Drives
PublikacjaCurrent sampling techniques and predictive algorithms used in the digital control of electric drives rely on a simple mathematical model that assumes linear current changes upon constant supplying voltages. This paper identifies rotor movement as a factor that makes this assumption invalid when the rotor covers an angular distance of a few tens of degrees during the control interval duration. The errors of the linear current approximation...
-
Quantitative structure–retention relationships in affinity high-performance liquid chromatography
Publikacja -
Size Exclusion Coupled to Reversed Phase Liquid Chromatography for the Characterization of Cranberry Products
PublikacjaA combination of solvent extraction, size exclusion purification, and reversed-phase liquid chromatography with UV absorption and fluorescence detection was here used for the determination of flavan-3-ols and related oligomeric compounds in cranberry products. The method relied on robust, simple, and inexpensive instrumental equipment present in most of routine analytical laboratories. Sample extracts in methanol/water/hydrochloric...
-
Usage of Over-the-Counter and Herbal Products in Common Cold in Poland: Findings from Consumer Survey
Publikacja -
An in situ derivatization – dispersive liquid–liquid microextraction combined with gas-chromatography – mass spectrometry for determining biogenic amines in home-made fermented alcoholic drinks
PublikacjaA novel dispersive liquid–liquid microextraction (DLLME) gas chromatography mass-spectrometry(GC–MS) method was developed for the determination of 13 biogenic amines in home-made wine sam-ples. The method allows to simultaneous extraction and derivatization of the amines providing a simpleand fast mode of extract enrichment. During the study, two different procedures were examined. Sta-tistical analysis was performed to choose...
-
The Influence of Limiters UEL and OEL (The power angle, stator's current and excitation current) ot the possibility of voltage collapse development
PublikacjaVoltage stability has been a major concern for power system utilities because of event of voltage collapses in the recent past. Sometimes, power system events have shown the need for generators to operate in the overexcited and underexcited region to support stable operation. Modern excitation systems include devices for controlling or limiting machine terminal voltage (overvoltage limiters), volts per hertz ratio (V/Hz limiters),...
-
Remote current measurement with FPGA digital processing
PublikacjaThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
Yerba Mate - A Long but Current History
PublikacjaBearing in mind the growing interest in Yerba Mate, a comprehensive study has been prepared containing the most important aspects and possibilities of its use. The introduction of the work contains the species characteristics of Yerba Mate, as well as information about the origin and places of cultivation. The next part focuses on the analysis of the composition, pointing to purine alkaloids, polyphenols, saponins, and minerals...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Liquid chromatography tandem mass spectrometry study of urinary nucleosides as potential cancer markers
Publikacja -
Suppression of deleterious effects of free silanols in liquid chromatography by imidazolium tetrafluoroborate ionic liquids
Publikacja -
Current advances in membrane processing of wines: A comprehensive review
PublikacjaBackground Membrane-based operations, especially pressure-driven membrane operations, are today well-established procedures for various applications in the wine industry thanks to their intrinsic properties and undoubted advantages over traditional methods. Emerging membrane processes, such as pervaporation, electrodialysis and osmotic distillation, forward osmosis, membrane contactors, offer new and interesting perspectives to...
-
Optimization of a Fabric Phase Sorptive Extraction protocol for the isolation of six bisphenols from juice pouches to be analysed by high performance liquid chromatography coupled with diode array detector
PublikacjaFabric Phase Sorptive Extraction (FPSE) combined with high pressure liquid chromatography using to diode array detection (HPLC-DAD) was applied for the simultaneous determination of bisphenols (BPA, BPB, BPC, BPE, BPF, BPS) in juice pouches. The FPSE procedure was optimized with regards to the critical parameters that affect the performance of the method including the selection of the FPSE membrane type and size, adsorption time,...
-
Requirements for Residual Current Devices Intended for Electric Vehicle Charging Systems
PublikacjaThe properties of residual current devices have been presented from the point of view of their ability to detect a specific shape of the residual current waveform. Moreover, the standard requirements relating to residual current protection used in electric vehicle charging installations have been pointed out. The operating characteristics of the IC-CPD and RDC-DD protections, which are intended for charging electric vehicles in...
-
Determination of Biogenic Amines in Wine Using Micellar Electrokinetic Chromatography
PublikacjaProduction on a large-scale of fermented alcoholic drinks made from different kinds of fruits is carried out in homes. Although wine laws regulating home production exist, they do not include upper concentration limits of biogenic amines. Therefore, a quick and inexpensive way to determine BAs in wine is crucial. A new analytical method based on micellar electrokinetic chromatography has been developed for the separation of the...
-
“Dilute & Shoot” approach for rapid determination of trace amounts of nicotine in zero-level e-liquids by reversed phase liquid chromatography and hydrophilic interactions liquid chromatography coupled with tandem mass spectrometry-electrospray ionization
Publikacja