Filtry
wszystkich: 5144
wybranych: 1565
-
Katalog
- Publikacje 1565 wyników po odfiltrowaniu
- Czasopisma 48 wyników po odfiltrowaniu
- Osoby 36 wyników po odfiltrowaniu
- Projekty 3 wyników po odfiltrowaniu
- Laboratoria 2 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 25 wyników po odfiltrowaniu
- Wydarzenia 5 wyników po odfiltrowaniu
- Dane Badawcze 3458 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: X-RAY TOMOGRAPHY
-
X-ray photoelectron spectroscopy, Raman and photoluminescence studies on formation of defects in Cu:ZnO thin films and its role in nonlinear optical features
Publikacja -
5- epi -Incensole: synthesis, X-ray crystal structure and absolute configuration by means of ECD and VCD studies in solution and solid state
Publikacja -
Evolution of the nanostructure of Pt and Pt–Co polymer electrolyte membrane fuel cell electrocatalysts at successive degradation stages probed by X-ray photoemission
PublikacjaWe present a set of XPS (X-ray photoemission spectroscopy) measurements and detailed data-analysis of electrodes for polymer electrolyte membrane fuel cell (PEMFC) based on carbon supported catalysts (Pt and Pt–Co) subjected to a step-like potential cycling (accelerated degradation test). The results of the measurements complete and corroborate parallel TEM (transmission electron microscopy), XRD (X-ray diffraction) and XAS (X-ray...
-
Enhancement of the Magnetic Coupling in Exfoliated CrCl 3 Crystals Observed by Low‐Temperature Magnetic Force Microscopy and X‐ray Magnetic Circular Dichroism
PublikacjaMagnetic crystals formed by 2D layers interacting by weak van der Waals forces are currently a hot research topic. When these crystals are thinned to nanometric size, they can manifest strikingly different magnetic behavior compared to the bulk form. This can be the result of, for example, quantum electronic confinement effects, the presence of defects, or pinning of the crystallographic structure in metastable phases induced by...
-
New examples of N^(+)-H···^(-)S hydrogen bonds: Synthesis and X-ray study of selected secondary ammonium tri-tert-butoxysilanethiolates
PublikacjaTri-tert-butoksysilanotiol reagując z aminami drugorzędowymi: Et2NH, morfoliną, dicykloheksyloaminą i 2,2,4,4-tetrametylopiperydyną daje odpowiednie sole amoniowe. Jak wykazują rentgenowskie badania strukturalne wszystkie te związki tworzą w ciele stałym jednostki dimeryczne {RS(-), R'NH2(+)}2, powiązane wiązaniami wodorowymi typu: N(+)-H···(-)S.
-
π-Indenyl substituted zirconium compounds containing terminal bondedphosphanylphosphido ligands [Ind2Zr(Cl){(Me3Si)P-PR2-jP1}]. Synthesis,X-ray analysis and NMR studies
PublikacjaPraca prezentuję reakcję kompleksów indenylowych cyrkonu z solami litowymi difosfanów o ogólnym wzorze R2P-P(SiMe3)Li, gdzie R = tBu, Et2N, iPr2N. W wyniku tych reakcji otrzymano 3 nowe kompleksy fosfanylofosfidowe.Otrzymane nowe kompleksy zbadano przy pomocy technik rentgenowskiej analizy strukturalnej i NMR.Dichloro-bis(indenyl)zirconium(IV) reacts with lithium derivatives of diphosphanes R2P-P(SiMe3)Li (R = tBu, Et2N, iPr2N)...
-
Adsorption behavior and corrosion inhibitive characteristics of newly synthesized cyano-benzylidene xanthenes on copper/sodium hydroxide interface: Electrochemical, X-ray photoelectron spectroscopy and theoretical studies
PublikacjaElegant process for synthesis of 3-(7H-dibenzo[c,h]xanthen-7-yl)benzaldehyde (3), as new starting material to create a set of novel xanthene analogues, 2-(3-(7H-dibenzo[c,h]xanthen-7-yl)benzylidene)malononitrile (4), 3-(3-(7H-dibenzo[c,h]xanthen-7-yl)phenyl)-2-cyanoacrylic acid (5), and Ethyl-3-(3-(7H-dibenzo[c,h]xanthen-7-yl)phenyl)-2-cyanoacrylate (6), was achieved starting with available materials under mild conditions. Various...
-
The X-ray crystallographic structures, spectral and magnetic properties of nickel(II), copper(II) and cobalt(II) complexes with tetra(3-iso-propylpyrazol-1-yl)borate
Publikacja -
Lower rim substituted p-tert-Butylcalix[4]arenes: Part XI. New ester derivatives of calix[4]arene, their ionophoric properties and x-ray structure studies
PublikacjaPrzedstawiono syntezę 6-ciu nowych estrowych pochodnych kaliks[4]arenuw konformacji stożkowej. Pierwsze badania kompleksowania jonów metali przeprowadzone w membranach elektrod jonoselektywnych (ISE) potwierdziły kompleksowanie jonów sodu w sposób selektywny. Zaprezentowano strukturę rentgenowską monokryształów związku 6.
-
π-Indenyl substituted zirconium compounds containing terminal bonded phosphanylphosphido ligands [Ind2Zr(Cl){(Me3Si)P–PR2-κP1}]. Synthesis, X-ray analysis and NMR studies
Publikacja -
Modeling of the alcohol dehydrogenase active site. Two different modes of alcohol binding in crystals of zinc and cadmium tri-tert-butoxysilanethiolates evidenced by X-ray diffraction and solid state vibrational spectroscopy
PublikacjaOpisano syntezę, struktury cząsteczkowe oraz widma FT-IR, 1H. 13C, 29Si, 113Cd NMR dziesięciu nowych, mieszanoligandowych kompleksów cynku i kadmu z ligandem tri-tert-butoksysilanotiolanowym i pochodnymi imidazolu. Za pomocą rentgenowskiej analizy strukturalnej i spektroskopii w podczerwieni udokumentowano dwa różne sposoby wiązania etanolu i metanolu w kryształach tych związków. Opisane kompleksy stanowią modele miejsca aktywnego...
-
Pomiary naprężeń w warstwie wierzchniej stali duplex metodą dyfrakcji promieniowania rentgenowskiego g-sin2Ψ = Residual stress measurements in duplex steel surface layers by g-sin2Ψ x-ray diffraction method
PublikacjaPrzedstawiono wyniki pomiarów naprężeń w warstwie wierzchniej z wykorzystaniem metody dyfrakcji promieniowania rentgenowskiego g-sin2. Wyjaśniono zasady przeprowadzania pomiarów naprężeń na próbkach walcowych o małej średnicy. Badania prowadzono na próbkach okrągłych ze stali duplex, poddanych procesom nagniatania. Stwierdzono występowanie naprężeń ściskających w warstwach powierzchniowych wszystkich badanych próbek oraz istotne...
-
Internal imaging of concrete fracture based on elastic waves and ultrasound computed tomography
PublikacjaThe condition assessment of concrete structures belongs to the greatest challenges of non-destructive testing. Monitoring the fracture process of concrete and detecting cracks at the earliest possible stage is a vital aspect to ensure the safety of civil engineering objects. The use of ultrasound tomography enables imaging the internal structure of a tested element. This study aims at the visualization of fracture damage in concrete...
-
Wykorzystanie tomografii komputerowej przy analizie jakości zacementowania - migracja gazu
PublikacjaArtykuł przedstawia opis zjawiska znanego w wiertnictwie otworowym jako migracja gazu. Opisano główne przyczyny powstawania tego negatywnego zjawiska polegającego na przepływie gazów a także płynów w zaczynie cementacyjnym lub kamieniu cementowym. Przygotowano próbki imitujące zacementowany odcinek rur okładzinowych. Skupiono się na wykorzystaniu tomografii komputerowej, oraz analizie zrekonstruowanego trójwymiarowego obrazu, w...
-
Evaluation of the structures size in the liquid-gas flow by gamma-ray absorption
PublikacjaThe rapid development of tomography methods particularly electrical, X and gamma rays allows for a wide range of the information about flow structure. However, all of such methods are quite complicated. At the same time much simpler systems as the measuring system of gamma rays absorption, allows to obtain a all key flow information which describe the two-phase flow. In the article the results of analyzes of radiometric signal...
-
Experimental investigations of damage evolution in concrete during bending by continuous micro-CT scanning
PublikacjaThe paper describes experimental investigation results of fracture in notched concrete beams under quasi-static three-point bending. To visualize 3D fracture in concrete under bending, an extended X-ray micro-computed tomography system was used, i.e. the tomography system SkyScan 1173 was connected to the loading machine ISTRON 5569. This combined system enabled to shot images of deforming concrete beams during a continuous deformation...
-
Pre-oxidation of porous ferritic Fe22Cr alloys for lifespan extension at high-temperature
PublikacjaPre-oxidation of porous ferritic Fe22Cr alloys was extensively studied in this paper. Weight gain measurements and SEM analysis revealed that pre-oxidation performed at 900◦C for 40 min increased the lifespan of the alloy. A Cr evaporation study did not disclose any significant influence of the pre-oxidation process on the Cr content in the alloy. For a more detailed assessment, TEM imaging and X-ray tomography measurements of...
-
Application of twin-plane ECT sensor for identification of the internal imperfections inside concrete beams
PublikacjaThe main purpose of this paper is to investigate application of special construction of Electrical Capacitance Tomography (ECT) sensor to concrete beams internal homogeneity tests. Identification of internal imperfection inside the concrete beams is one of the main problems related to analysis of the construction structure bearing capacity. Therefore, this paper shows attempts to study the measurement prospects for this non-invasive,...
-
The Effect of Fly Ash Microspheres on the Pore Structure of Concrete
PublikacjaThe fly ash microspheres (FAMs) formed during the mineral transformation stage in coal combustion are hollow spherical particles with a density less than water. This paper presents the results of X‐ray micro‐computed tomography and an automatic image analysis system of the porosity in the structure of hardened concrete with microspheres. Concrete mixtures with ordinary Portland cement and two substitution rates of cement by microspheres—5%...
-
SIMULATIONS OF FRACTURE IN CONCRETE BEAMS UNDER BENDING USING A CONTINUUM AND DISCRETE APPROACH
PublikacjaThe paper describes two-dimensional meso-scale results of fracture in notched concrete beams under bending. Concrete was modelled as a random heterogeneous 4-phase material composed of aggregate particles, cement matrix, interfacial transitional zones and air voids. Within continuum mechanics, the simulations were carried out with the finite element method based on a isotropic damage constitutive model enhanced by a characteristic...
-
Non-destructive Testing of Wooden Elements
PublikacjaExamining the condition of wooden elements is crucial from the perspective of proper structure performance. If the deterioration in the internal wood condition, which displays no symptoms visible from the outside, is detected, the further spread of the deterioration can be prevented. Test results often point to the necessity of conducting repairs and, renovations, replacing the structure of wooden beams, or even substituting a...
-
Effect of plasma sprayed and laser re-melted Al2O3 coatings on hardness and wear properties of stainless steel
PublikacjaCommercially available austenic stainless steel substrate was coated with commercially available, raw Al2O3 powder applied by means of plasma spraying method and then re-melted with CO2 laser beam of various parameters. Tribological and mechanical properties of the 120 J/mm and 160 J/mm laser re-melted coatings were compared with the tribological and mechanical properties of the “as-sprayed” coating. The influence of the laser...
-
EXPERIMENTAL AND NUMERICAL INVESTIGATIONS OF CONCRETE BEHAVIOUR AT MESO-LEVEL DURING QUASI-STATIC SPLITTING TENSION
PublikacjaThe paper describes experimental and numerical results of quasi-static splitting tensile tests on concrete specimens at meso-scale level. The loading strip was made of plywood or steel. Fracture in concrete was detected at the aggregate level by means of three non-destructive methods: 3D x-ray micro-computed tomography, 2D scanning electron microscope and manual 2D digital microscope. The discrete element method was used to directly...
-
Discrete element method simulations of fracture in concrete under uniaxial compression based on its real internal structure
PublikacjaThe paper describes experimental and numerical results of concrete fracture under quasi-static uniaxial compression. Experimental uniaxial compression tests were performed on concrete cubic specimens. Fracture in concrete was detected at the aggregate level by means of three non-destructive methods: three-dimensional X-ray microcomputed tomography, two-dimensional scanning electron microscope and manual two-dimensional digital...
-
Non-uniqueness of fracture parameter choice in simulations of concrete cracking at mesoscale level
PublikacjaIn the paper a non-uniqueness of fracture parameter choice in simulations of cracking process in plain concrete specimens at mesoscale level under monotonic static loading is analysed. The Finite Element Method is used, where cracks are defined in a discrete way using interface cohesive elements with nonlinear material law including softening. The concrete mesostructure (such as: cement matrix, air voids, aggregates, and Interfacial...
-
Investigations on fracture in reinforced concrete beams in 3-point bending using continuous micro-CT scanning
PublikacjaThis study explores a fracture process in rectangular reinforced concrete (RC) beams subjected to quasi-static three-point bending. RC beams were short and long with included longitudinal reinforcement in the form of a steel or basalt bar. The ratio of the shear span to the effective depth was 1.5 and 0.75. The focus was on the load–deflection diagram and crack formation. Three-dimensional (3D) analyses of the size and distribution...
-
POM/EVA Blends with Future Utility in Fused Deposition Modeling
PublikacjaPolyoxymethylene (POM) is one of the most popular thermoplastic polymers used in the industry. Therefore, the interest in its potential applications in rapid prototyping is understandable. Nevertheless, its low dimensional stability causes the warping of 3D prints, limiting its applications. This research aimed to evaluate the effects of POM modification with ethylene-vinyl acetate (EVA) (2.5, 5.0, and 7.5 wt.%) on its processing...
-
Insight into the microstructural and durability characteristics of 3D printed concrete: Cast versus printed specimens
PublikacjaThis study presents the comparison of microstructural and durability characteristics of 3D printed concrete (3DPC) depending on its production method (printing or casting). Printed samples with different numbers of layers, as well as a cast specimen with an identical mix composition, were produced and compared, with their microstructural pore and solid characteristics quantitatively and qualitatively investigated. For this purpose,...
-
Mechanical Properties of Additively Manufactured Polymeric Materials—PLA and PETG—For Biomechanical Applications
PublikacjaThe study presented herein concerns the mechanical properties of two common polymers for potential biomedical applications, PLA and PETG, processed through fused filament fabrication (FFF)—Material Extrusion (ME). For the uniaxial tension tests carried out, two printing orientations—XY (Horizontal, H) and YZ (Vertical, V)—were considered according to the general principles for part positioning, coordinates, and orientation typically...
-
Influence of Surface-Modified Montmorillonite Clays on the Properties of Elastomeric Thin Layer Nanocomposites
PublikacjaIn recent years, polyurethane nanocomposites have attracted more attention due to the massive demand for materials with increasingly exceptional mechanical, optical, electrical, and thermal properties. As nanofillers have a high surface area, the interaction between the nanofiller and the polymer matrix is an essential issue for these materials. The main aim of this study is to validate the impact of the montmorillonite nanofiller...
-
Quantitative Active Dynamic Thermal IR-Imaging and Thermal Tomography in Medical Diagnostic
PublikacjaPrinciples of Active dynamic thermal (ADT) IR-imaging and Thermal Tomography are described in details. Basic medical applications of this new modality are also discussed.
-
Ultrasonic Tomography of Brick Columns Based on FEM Calculations
PublikacjaUltrasonic tomography is one of the most developed method of non-destructive testing. Despite being used mainly in medicine, it is becoming more and more popular as a method for monitoring of structural elements. It allows to examine the internal structure and technical condition of the tested element. This paper investigates the influence of crosssectional geometry on an obtained tomographic image. Wave propagation signals were...
-
Imaging of Increasing Damage in Steel Plates Using Lamb Waves and Ultrasound Computed Tomography
PublikacjaThis paper concerns inspection of steel plates, with particular emphasis on the assessment of in-creasing damage. Non-destructive tests were performed on four plates, one of which was un-damaged, while the remaining three had a defects in the form of circular holes with a diameter of 2, 5, and 10 cm. Guided Lamb waves were used in the research, and the image reconstruction was performed using ultrasound computed tomography. The...
-
Using the ultrasonic tomography method to study the condition of wooden beams from historical buildngs
PublikacjaThe need to evaluate the integrity of wooden structural elements is constantly increasing. Non-destructive methods are becoming more popular in this field of research. One type of non-destructive testing is the ultrasonic imaging method, which allows the analysis of internal wood structures without disturbing their state and integrity. In this study, we are interested in assessing the effect of wood condition on the ultrasound...
-
Microstructure–Property Relationship of Polyurethane Foams Modified with Baltic Sea Biomass: Microcomputed Tomography vs. Scanning Electron Microscopy
PublikacjaIn this paper, novel rigid polyurethane foams modified with Baltic Sea biomass were compared with traditional petro-based polyurethane foam as reference sample. A special attention was focused on complex studies of microstructure, which was visualized and measured in 3D with high-resolution microcomputed tomography (microCT) and, as commonly applied for this purpose, scanning electron microscopy (SEM). The impact of pore volume,...
-
Gold nanoparticles evaluation using functional optical coherence tomography
PublikacjaThe main object of this research was to assess the ability to characterize the gold nanoparticles using optical modalities like optical coherence tomography. Since the nanoparticles, especially gold one, have been very attractive for medical diagnosis and treatment the amount of research activities have been growing rapidly. The nanoparticles designed for different applications like contrast agents or drugs delivery change the...
-
Integration and verification of meteorological observations and NWP model data for the local GNSS tomography
PublikacjaGNSS meteorology applies the Global Navigation Satellite Systems (GNSS) to derive information about the state of the atmosphere (particularly troposphere). The tomography is one of the methods used in GNSS meteorology. The input data of GNSS tomography are the signal troposphere delays, results of GNSS data processing and additionally meteorological observations and Numerical Weather Prediction (NWP) models data. Different types...
-
1D portable optical coherence tomography system
Publikacja—Imaging methods are an expanding branch of technology, which involves data acquisition and analysis of images for research and diagnostics. This paper has been devoted to the description of the optical design for a one-dimensional, portable optical coherence tomography (OCT) system. The Mach-Zehnder interferometer has been designed in the presented study. The description of the construction and applied hardware solutions have...
-
Microcrystalline diamond film evaluation by spectroscopic optical coherence tomography
PublikacjaThis study has focused on the microcrystalline diamond film (MCD) thickness evaluation. For this purpose, optical coherence tomography (OCT) enhanced by spectroscopic analysis has been used as a method of choice. The average thickness of the tested layer was about 1.5 µm, which is below the standard 2-point OCT resolution. In this case, the usefulness of the spectroscopic analysis was confirmed for the evaluation of the thickness...
-
Nanomateriały o właściwościach magnetycznych, fotokatalitycznych, biobójczych
PublikacjaTematyka badawcza pracy doktorskiej obejmuje preparatykę i charakterystykę nanomateriałów o właściwościach magnetycznych, fotokatalitycznych, biobójczych. Celem pracy była preparatyka nanomateriałów na bazie TiO2 oraz ZnFe2O4 oraz zastosowanie nanokompozytów w fotokatalizie heterogenicznej do degradacji ksenobiotyków niepodatnych na rozkład biologiczny i otrzymywania funkcjonalnych materiałów budowlanych. Otrzymane nanokompozyty...
-
Non-Destructive Assessment of Masonry Pillars using Ultrasonic Tomography
PublikacjaIn this paper, a condition assessment of masonry pillars is presented. Non-destructive tests were performed on an intact pillar as well as three pillars with internal inclusions in the form of a hole, a steel bar grouted by gypsum mortar, and a steel bar grouted by cement mortar. The inspection utilized ultrasonic stress waves and the reconstruction of the velocity distribution was performed by means of computed tomography. The...
-
Parallel multithread computing for spectroscopic analysis in optical coherence tomography
PublikacjaSpectroscopic Optical Coherence Tomography (SOCT) is an extension of Optical Coherence Tomography (OCT). It allows gathering spectroscopic information from individual scattering points inside the sample. It is based on time-frequency analysis of interferometric signals. Such analysis requires calculating hundreds of Fourier transforms while performing a single A-scan. Additionally, further processing of acquired spectroscopic information...
-
Polarization-sensitive optical coherence tomography for ceramic materials inspection
PublikacjaCeramics production is looking for a fast, reliable and non-destructive method that can be implemented on site for defect detection and analysis. In this paper we present polarization-sensitive optical coherence tomography (PS-OCT) as a method for defect inspection. Proposed extensions to standard OCT provide additional information for complete characterization of tested object. We compare OCT and microscope imaging that can easily...
-
Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method
PublikacjaNumerical modeling Optical Coherence Tomography (OCT) systems is needed for optical setup optimization, development of new signal processing methods and assessment of impact of different physical phenomena inside the sample on OCT signal. The Monte Carlo method has been often used for modeling Optical Coherence Tomography, as it is a well established tool for simulating light propagation in scattering media. However, in this method...
-
Adaptive Hounsfield Scale Windowing in Computed Tomography Liver Segmentation
PublikacjaIn computed tomography (CT) imaging, the Hounsfield Unit (HU) scale quantifies radiodensity, but its nonlinear nature across organs and lesions complicates machine learning analysis. This paper introduces an automated method for adaptive HU scale windowing in deep learning-based CT liver segmentation. We propose a new neural network layer that optimizes HU scale window parameters during training. Experiments on the Liver Tumor...
-
Efficient signal processing in spectroscopic optical coherence tomography
PublikacjaSpectroscopic optical coherence tomography (SOCT) is an extension of a standard OCT technique, which allows to obtain depth-resolved, spectroscopic information on the examined sample. It can be used as a source of additional contrast in OCT images e.g. by encoding certain features of the light spectrum into the hue of the image pixels. However, SOCT require computation of time-frequency distributions of each OCT A-scan, what is...
-
Detection of petroleum products using optical coherence tomography
PublikacjaIn this work, we present a novel method developed for the analysis of the properties of thin layers for detecting petroleum products on a water surface using a commercially available optical coherence tomography (OCT) system. The spectral density analysis of the signal from a spectroscopic OCT (S-OCT) enables us to perform the precision calculation of the thin layer thickness and other properties like homogeneity, and dispersion,...
-
Assessment of Wooden Beams from Historical Buildings Using Ultrasonic Transmission Tomography
PublikacjaThe main goal of this study was non-destructive evaluation of wooden elements using ultrasonic waves. The inspection was carried out on wooden beams from a historical object. Elastic wave signals were processed by ultrasonic transmission tomography to obtain imaging of the internal structure of tested elements without disturbing their state and integrity. The focus was on the influence of wood anisotropy on the propagation of ultrasonic...
-
Nanoparticles displacement analysis using optical coherence tomography
PublikacjaOptical coherence tomography (OCT) is a versatile optical method for cross-sectional and 3D imaging of biological and non-biological objects. Here we are going to present the application of polarization sensitive spectroscopic OCT system (PS-SOCT) for quantitative measurements of materials containing nanoparticles. The PS-SOCT combines the polarization sensitive analysis with time-frequency analysis. In this contribution the benefits...
-
Novel method of lung area extraction in chest perfusion computed tomography
PublikacjaChest perfusion computed tomography (pCT) is a useful technique in the medical diagnosis of how organs function. Perfusion CT scans are used to calculate perfusion parameters. In the case of automated methods of lung perfusion parameters calculation, the prior extraction of the lung area is desired to avoid unnecessary calculation in an area outside the lung cross-section and to avoid wasting time on processing signals of no diagnostic...