Filtry
wszystkich: 3471
-
Katalog
- Publikacje 2348 wyników po odfiltrowaniu
- Czasopisma 44 wyników po odfiltrowaniu
- Konferencje 7 wyników po odfiltrowaniu
- Osoby 34 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Zespoły Badawcze 2 wyników po odfiltrowaniu
- Kursy Online 20 wyników po odfiltrowaniu
- Dane Badawcze 1014 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: measurement
-
<title>Cavity simulator and controller for VUV free electron laser SIMCON 2.1, part III: I/O ports and measurement results</title>
Publikacja -
A.D.A.M. test (Antibiofilm Dressing's Activity Measurement) — Simple method for evaluating anti-biofilm activity of drug-saturated dressings against wound pathogens
Publikacja -
The Effect of Full-Cell Impregnation of Pine Wood (Pinus sylvestris L.) on Changes in Electrical Resistance and on the Accuracy of Moisture Content Measurement Using Resistance Meters
PublikacjaThe impact of the full-cell impregnation of pine wood was investigated with respect to changes in electrical resistance and the accuracy of moisture content measurement. This study compared the resistance of impregnated and untreated pine timber harvested from the northern part of Poland (Pomeranian region). The wood was impregnated by the vacuum-pressure method. The preservative (TANALITH E 3475) and coloring (TANATONE 3950) agents...
-
Different Ways to Apply a Measurement Instrument of E-Nose Type to Evaluate Ambient Air Quality with Respect to Odour Nuisance in a Vicinity of Municipal Processing Plants
PublikacjaThis review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents...
-
Comparative field test for measurement of PM10 dust in atmospheric air using gravimetric (reference) method and b-absorption method (Eberline FH 62-1)
PublikacjaThe paper presents the results of a field test carried out in Gdansk region between 01-01-2010 and 31-12-2010 in order to demonstrate equivalence of the Eberline FH 62-1 sampler to the reference gravimetric method of suspended PM10 dust measurement. The differences in PM10 dust concentration provided by both methods have been discussed for different seasons of the year. A method of estimation of the correction factors/correction...
-
Measurement report: Spatial variations in ionic chemistry and water-stable isotopes in the snowpack on glaciers across Svalbard during the 2015–2016 snow accumulation season
PublikacjaThe Svalbard archipelago, located at the Arctic sea-ice edge between 74 and 81∘ N, is ∼60 % covered by glaciers. The region experiences rapid variations in atmospheric flow during the snow season (from late September to May) and can be affected by air advected from both lower and higher latitudes, which likely impact the chemical composition of snowfall. While long-term changes in Svalbard snow chemistry have been documented in...
-
Corrigendum to “Fatigue life improvement using low transformation temperature weld material with measurement of residual stress” [Int. J. Fatigue 164 (2022) 107137]
PublikacjaWelding processes often produce high levels of tensile residual stress. Low transformation temperature (LTT) welding wires utilise phase transformation strains to overcome the thermal contraction of a cooling weld. In this paper, the residual stress within each weld was quantified using the milling/strain gauge method, being the strain change measured as the weldment was milled away. The fatigue tests were conducted under uniaxial...
-
O wyszukiwaniu niepoprawnych pomiarów w systemach DCS obiektów energetycznych = On search for incorrect measurement results in distributed control systems (DCS) of power objects
PublikacjaPrzedyskutowano problem rozpoznawania degradacji mierników pomiarowych w systemach DCS dużych obiektów energetycznych, przy równoczesnym występowaniu degradacji eksploatacyjnej urządzeń składowych tych obiektów. Zastosowano sieć neuronową (SNN) o skokowych funkcjach przejścia. Zastosowana SNN wykazała wysoką jakość. Sprawdzono możliwości rozpoznawania obu typów degradacji występującej w zastosowaniu do tzw. degradacji dwukrotnych.
-
Eine Eeue Technik zur Präzisen Rissfortschrittsmessung im DCB oder im Keilversuch = A novel technique for precise crack length measurement in the DCB or wedge test
PublikacjaDiverse methods have been tried to study crack length, most basic relying on direct, or microscopic, observation of the crack tip position. Optical correlation, both lasermoiré and speckle interferometry, a single strain gauge and displacement sensorshave also been employed. Crack length measurement is, however, delicate. We present a novel method making use of strain gauges attached to one of the adherends.
-
IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY
Czasopisma -
The loop impedance measurement
Dane BadawczeThe loop impedance measurement
-
Measurements and Measurements Systems [2023/24]
Kursy Online -
International Symposium on Empirical Software Engineering and Measurement
Konferencje -
Measurement of plasma 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in population of patients with cardiovascular disease by UPLC-MS/MS method
Publikacja -
<title>Modular version of SIMCON, FPGA based, DSP integrated, LLRF control system for TESLA FEL part II: measurement of SIMCON 3.0 DSP daughterboard</title>
Publikacja -
Poziomy stężeń lotnych związków chlorowcoorganicznych w wodach opadowych na terenie dużej aglomeracji miejskiej = Measurement of volatile chloroorganic compounds in urban rainwater (Gdańsk, Sopot, Gdynia)
PublikacjaW 105 próbkach opadów atmosferycznych (deszcz, deszcz ze śniegiem) zebranych z terenu Trójmiasta w okresie od listopada 2000 r. do maja 2001 r. oznaczano chloro - i bromopochodne metanu, etanu i etenu (7 różnych związków). Najczęściej wykrywanymi i oznaczanymi były: chloroform i czterochlorek węgla, (bardzo popularne rozpuszczalniki stosowane jako środki chłodzące i czyszczące). Najwyższe stężenia obserwowano w przypadku chloroformu,...
-
Measurement of activity coefficients at infinite dilution of organic solutes in the ionic liquid 1-hexyl-1,4-diaza[2.2.2]bicyclooctanium bis(trifluoromethylsulfonyl)imide using gas–liquid chromatography
PublikacjaBased on gas–liquid chromatography (GLC) retention data, activity coefficients at infinite dilution of 39 different solutes in the ionic liquid 1-hexyl-1,4-diaza[2.2.2]bicyclooctanium bis(trifluoromethylsulfonyl)imide ([HDABCO][NTf2]) have been determined. Measurements covered a broad range of types of organic solutes including alkanes, alcohols, ketones, benzene derivatives and McReynold’s compounds. Activity coefficients were...
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
O zastosowaniu metody prądów wirowych do technicznego pomiaru własności elektrycznych i magnetycznych metali = About application of eddy current method for technical measurement of electric and magnetic properties of metals
PublikacjaOpisano wyniki badań nad wykorzystaniem efektu prądów wirowych do badania własności elektrycznych i magnetycznych metali. Badania wykonano za pomocą sondy różnicowej. Wyniki pomiarów zależności częstotliwościowej wykonane dla modelowych materiałów porównano z wynikami modelowania metodą elementów skończonych.
-
Long-term measurement of physiological parameters.
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Distance measurement by the low coherent interferometer
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
The TEC measurement of LSCNT (dilatometry) in air
Dane BadawczeThe dataset includes dilatometry results for La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s measured in air from 100 to 800C using Netzsch DIL 402 PC.
-
Joint Conference of the International Workshop on Software Measurement and the International Conference on Software Process and Product Measurement (IWSM and Mensura combined from 2007)
Konferencje -
IFIP International Symposium on Computing Performance, Modelling, Measurement and Evaluation
Konferencje -
IEEE International Conference on Computational Intelligence for Measurement Systems and Applications
Konferencje -
ECG measurement in the bathtub - getting into the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Long-term measurement of physiological parameters (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Adsorption and desorption of N2 measurement of MXenes catalysts
Dane BadawczeData contain results from adsorption and desorption of N2 measurement of the Ti3C2Tx MXenes produced via acidic etching aluminum from MAX Phase (Ti3C2-Al-Ti3C2-Al-Ti3C2) using different etching agents, HF/HCl and HF/H2SO4 with different weight ratios (1:3, 1:4, and 1:5). The samples were labeled as MXene HF/HCl X:Y and MXene HF/H2SO4 X:Y, where X:Y...
-
XPS measurement of the Fe-Ti based materials
Dane BadawczeThe mono‐ and bimetal‐modified (Pd, Cu) titanium(IV) oxide and iron oxide (III) photocatalysts were prepared by chemical reduction method and characterized using XPS method. The composition of elements incorporated in the surface layer of mono- and bimetallic photocatalysts was determined by XPS analysis, as well as the valence state of elements. Measurements...
-
Measurement data of cyclic voltammetry and electrochemical impedance measurements of carbon samples synthesized on axes and off axes
Dane BadawczeThe electrochemical performance of the multielectrode samples were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using a VMP-300 BioLogic galvanostat potentiostat (France) under the EC-lab software. All electrochemical investigations were carried out in a three-electrode cell system. The carbon multi-electrode,...
-
Long-term measurement of physiological parameters - child (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - adult (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 110 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (4h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (13h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (13 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (10h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (10 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Light transmission measurement through the fluidized bed photoreactor
Dane BadawczeDataset contains light transmission measurements through the fluidized bed photoreactor. Two sources of light were used: UV-LEDs and UV fluorescent. Measurements were performed at different air flows: 0, 80, 160 and 240 ml/min. The detailed measurement and equipment data was described in measurment info.txt file.
-
Measurement of the tram rail profile during a year of operation
Dane BadawczeThe aim of the work was to analyze the wear of rails during operation and to analyze the supplementation of heavy metals in the soil around the tram route, originating from wearing out rails and tram wheels.The dataset contains measurements of rail head coordinates in 9 research sections made in 8 measurement series. The wear of the rails in selected...
-
LIDAR data from the measurement of a WD113 bridge structure
Dane BadawczeThe measurement data was obtained during research related to the utilization of LiDAR observations to assess the condition of bridge structures. The provided data comes from measurements of viaduct WD113 located along a newly built national road near the town of Koszalin. The acquired point cloud constitutes an integral set of information regarding...
-
Short-term measurement of physiological parameters - adult (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (30 minutes) measurement of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - child (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurement of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - adult (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurement of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Reinforced aluminium reference measurement R63 – earlier tests
Dane BadawczePreliminary testing of aluminium alloys against 100Cr6 steel ball. Preparation to tests on wear of Al6061 alloy in ball on disk experiment. Research on the reinforcing effect of aluminium alloy injection reinforcement with TiN and WC powders in laser remelted surface layer.
-
Reinforced aluminium reference measurement Result1 – earlier tests
Dane BadawczePreliminary testing of aluminium alloys against 100Cr6 steel ball. Preparation to tests on wear of Al6061 alloy in ball on disk experiment. Research on the reinforcing effect of aluminium alloy injection reinforcement with TiN and WC powders in laser remelted surface layer.
-
Optimization of impedance measurements using ‘chirp’ type perturbation signal
Publikacja