Wyniki wyszukiwania dla: INTERFERENCES - MOST Wiedzy

Wyszukiwarka

Wyniki wyszukiwania dla: INTERFERENCES

Wyniki wyszukiwania dla: INTERFERENCES

  • Validation of a virtual test environment for C2X communication under radio jamming conditions

    Publikacja

    - Rok 2020

    In this paper, we propose a novel car-2-x communication security testing methodology in the physical layer of wireless systems. The approach is dedicated to automated testing of autonomous vehicles and it is essential for such complex systems operation, especially with regard to safety and security issues. It is based on scenario-driven testing in virtual and real test environments created from collected or simulated data. The...

    Pełny tekst do pobrania w portalu

  • Low Frequency Conducted Emissions of Grid Connected Static Converters

    Publikacja

    Pulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Noise in biological Raman spectroscopy

    Publikacja

    - Rok 2015

    Raman spectroscopy is a widely used method to investigate chemical molecules by analyzing their vibrational transitions. It utilizes inelastic scattering of the laser light irradiating the investigated object. The scattered light requires appropriate filtering to reduce dominant laser light and expose much weaker components having shifted wavelengths of a characteristic spectral pattern. These components are measured by dispersing...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • High Frequency Harmonics Emission in Smart Grids

    Publikacja

    - Rok 2013

    Pulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Applications of Raman spectroscopy for detection of selected substances in tissues

    Publikacja

    - Rok 2019

    This dissertation explores the applications of Raman spectroscopy for biological tissue analysis. Basics of Raman and surface-enhanced Raman spectroscopy (SERS) are described, along with an analysis of the literature on biodetection and non-invasive blood analysis with emphasis on glucose detection. Instrumentation for Raman measurements is described. The sources of noise and interferences occurring in biological tissue measurements...

  • Green capsule phase microextraction employing hydrophobic monolithic sol-gel octadecyl siloxane platforms for the monitoring of organophosphorus pesticides in environmental water samples

    Publikacja
    • N. Manousi
    • A. Ferracane
    • A. Kabir
    • K. G. Furton
    • P. Q. Tranchida
    • G. A. Zachariadis
    • J. Płotka-Wasylka
    • L. Mondello
    • V. F. Samanidou
    • E. Rosenberg

    - Sustainable Chemistry and Pharmacy - Rok 2022

    In this study, a novel, facile and green capsule phase microextraction (CPME) method is presented for the extraction and preconcentration of organophosphorus pesticides (i.e., chlorpyrifos, disulfoton, ethoprophos, fenchlorphos, prothiofos, and parathion-methyl) from environmental water samples. Monolithic sol-gel octadecyl siloxane (sol-gel C18) sorbent encapsulated within porous polypropylene capsules was synthesized, characterized,...

    Pełny tekst do pobrania w portalu

  • Metody usuwania zakłóceń podczas pomiarów polowych widm Ramana

    W pracy zostały scharakteryzowane źródła zakłóceń występujące podczas pomiarów widm Ramana w warunkach polowych oraz sposoby redukcji ich wpływu na jakość rejestrowanych widm. Zaprezentowano wpływ czasu integracji na jakość rejestrowanych widm w przypadkach, gdy szumy własne spektrometru mają składową typu 1/f, dominującą w zakresie małych częstotliwości. Przedstawiono także wyniki uzyskane podczas pomiarów z detekcją synchroniczną,...

    Pełny tekst do pobrania w portalu

  • Nowe rozwiązania metodyczne i techniczne w zakresie techniki mikroekstrakcji do fazy stracjonarnej

    Sample preparation has been recognized as a critical step of the analytical process, being even considered as the bottleneck of the overall process. Enrichment of target compounds, transfer of the analytes into a solvent compatible with the analytical instrumentation, minimization of potential interferences, and efficient sample clean-up, are among the main aims of sample preparation techniques. In this regard, liquid-liquid extraction...