Wyniki wyszukiwania dla: ELECTROCHEMICAL IMPEDANCE
-
Charge Transport in High-Entropy Oxides
PublikacjaThis work presents the results of research on the transport properties of the high-entropy BaZr1/8Hf1/8Sn1/8Ti1/8Y1/8In1/8Sm1/8Yb1/8O3–x perovskite oxide with special focus on proton transport. The presented study is part of broader work in which we focus on multiple different chemical compositions with the cation number varying from 5 up to 12 (in B-sublattice). The presence of proton defects is analyzed with thermogravimetry,...
-
Solid State Conductivity of Optimized Polypyrrole Coatings on Iron Obtained from Aqueous Sodium Salicylate Solution Determined by Impedance Spectroscopy
PublikacjaIn this work the optimization procedure for corrosion resistance, surface analysis and electrical properties of PPy-Fe electrodes have been examined. Polypyrrole (PPy) film was electrochemically synthesized in a one step process from an aqueous solution of sodium salicylate and pyrrole with certain concentrations, different parameters and type of polymerization...
-
Analysis of the Possibility of Using New Types of Protective Coatings and Abrasion-Resistant Linings under the Operating Conditions of the Spiral Classifier at KGHM Polska Miedź S.A. Ore Concentration Plant
PublikacjaA study was carried out to select the appropriate coatings for corrosion protection of the spiral classifier working at KGHM Polska Miedź S.A. Ore Concentration Plant. The abrasion resistance of selected protective coatings and wear-resistant linings was investigated using a DT-523 rotary abrasion tester with Taber CS-10 rubber abrasive discs. The average weight loss of the coatings after a cycle of 2000 revolutions was determined....
-
The loop impedance measurement
Dane BadawczeThe loop impedance measurement
-
Dynamic impedance spectra of programmable dynamically changing RC model based on digital potentiometers
Dane BadawczeThe dataset presents non-stationary impedance spectra of the RC model presented in the figure below. This model contains two digital potentiometers controlled digitally by the microcontroller. This solution allows to programmably control the value of the model impedance. Thanks to this, the model can be used as a test engine for evaluation of the dynamic...
-
Impedance spectra of ZnO varistor type 280 model O M ver. 89
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Dane BadawczeThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 200 mV
Dane BadawczeThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 0 V
Dane BadawczeThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 600 mV
Dane BadawczeThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 400 mV
Dane BadawczeThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Dane BadawczeThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on "unknown" object using 2-wire probe
Dane BadawczeThe dataset presents impedance spectrum of "black-box" object with interesting phase characteristics. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 2
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 1
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 1
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Impedance spectra of ZnO varistor type 440 model A ver. M
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model A M ver. 93
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model O M ver. 65 13
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model A M ver. xx
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model A ver. M
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model 0 ver. 89
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model O ver. 68
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 100 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 440 model O ver. 68
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 10 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model O M ver. 65 60
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 10 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 2
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 24h exposition
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 48h exposition
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Simultaneous measurements of ECG, body Impedance and temperature
Dane BadawczeThe data are complementary part of the experiment designed to demonstrate how to use the network protocols to transmit medical data. The dataset contains biomedical signals of ECG, Impedanc and temperature acquired simultaneously. The data allow students to become familiar with data acquisition methods (simulate data transmission by medical device over...
-
Fitted impedance spectra of a symmetrical porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C, measured at 700 °C and 0.1% pO2) with an individual contributions of the respective fitting elements
Dane BadawczeThis dataset contains exemplary impedance spectra (measured at 700 °C and 0.1% pO2) for porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode sintered at 1000 °C. Results of symmetric cell impedance measurement were converted to electrode surfaces area and dived by two electrodes. Dataset conatins also fitting results and individual contributions of the respective...
-
Fitted impedance spectra of a symmetrical porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C, measured at 800 °C and 0.1% pO2) with an individual contributions of the respective fitting elements
Dane BadawczeThis dataset contains exemplary impedance spectra (measured at 800 °C and 0.1% pO2) for porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode sintered at 1000 °C. Results of symmetric cell impedance measurement were converted to electrode surfaces area and dived by two electrodes. Dataset conatins also fitting results and individual contributions of the respective...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
The AFM micrographs and impedance study of epoxy coatings after exposure in corrosive media
Dane BadawczeThe dataset contains Atomic Force Microscopy (AFM) images and local impedance measurements of epoxy organic coating used as anti-corrosion protection, before and after 2-month exposure to sodium chloride solution. Additionally, there two local impedance spectra recorded after the coating exposure. The first one was recorded on intact coating surface,...
-
Impedance spectra of RC model as a result of testing pulse excitation measurement method
Dane BadawczeThe impedance spectrum of RC model object obtained using pulse excitation EIS impedance spectrosocpy measurement method. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. The object under test was built using RC components connected as Baunier model of anticorrosion coating with the following components...
-
Linear impedance of Bi2VO5.5 glass-ceramic measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
The voltage across and current through the RC model object tested using pulse excitation in impedance spectroscopy measurement method
Dane BadawczeThe raw data (voltage across and current through RC model object ) obtained using pulse excitation EIS impedance spectroscopy measurement method. The data was acquired using 12-bit ADC (LTC1420) with sampling frequency changed in time segments. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. For...
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Linear impedance of Bi2VO5.5 glass-ceramic annealed at 423 K measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic annealed at 423 K prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Distribution of Relaxation Times analysis results of impedance of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C) as a function of measuring temperature at 0.1% pO2
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode as a function of measuring temperature at 0.1% pO2. Electrode was sintered at 1000 °C and measured at different temperatures (800 °C, 750 °C, 700 °C).
-
Linear impedance of V2O5 nanorods obtained at 903K
Dane BadawczeThe DataSet contains the linear electrical properties of V2O5 nanorods which were measured by the impedance spectroscopy method. V2O5 nanorods were obtained by the sol-gel method. The information about xerogel powder synthesis is described in the Journal of Nanomaterials. The precursor powder was pressed into the disk-shaped pellets (12mm in diameter...
-
Linear impedance of 0.5Si3N4–99.5(40Na2O-20CaO-40P2O5) glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of 0.5Si3N4–99.5(40Na2O-20CaO-40P2O5) glass was measured by impedance spectroscopy method.
-
Linear impedance of 40Na2O-20CaO-40P2O5 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of 40Na2O-20CaO-40P2O5 glass was measured by impedance spectroscopy method.
-
Linear impedance of 25Na2O–20CaO–5P2O5–50SiO2 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of 25Na2O–20CaO–5P2O5–50SiO2 glass was measured by impedance spectroscopy method.
-
Linear impedance of 1Si3N4–99(40Na2O-20CaO-40P2O5) glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of 1Si3N4–99(40Na2O-20CaO-40P2O5) glass was measured by impedance spectroscopy method.