Filtry
wszystkich: 6672
-
Katalog
- Publikacje 4946 wyników po odfiltrowaniu
- Czasopisma 69 wyników po odfiltrowaniu
- Konferencje 7 wyników po odfiltrowaniu
- Osoby 65 wyników po odfiltrowaniu
- Projekty 3 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 31 wyników po odfiltrowaniu
- Wydarzenia 2 wyników po odfiltrowaniu
- Dane Badawcze 1547 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: MEASUREMENT OF GAS TEMPERATURE
-
An electronic nose for quantitative determination of gas concentrations
PublikacjaThe practical application of human nose for fragrance recognition is severely limited by the fact that our sense of smell is subjective and gets tired easily. Consequen tly, there is considerable need for an instrument that can be a substitution of the human sense of smell. Electronic nose devices from the mid 1980s are used in growing number of applications. They comprise an array of several electrochemical gas sensors...
-
High temperature proton conduction in LaSbO4
PublikacjaLanthanum orthoantimonate was synthesized using a solid‐state synthesis method. To enhance the possible protonic conductivity, samples with the addition of 1 mol% Ca in La‐site, were also prepared. The structure was studied by the means of X‐ray diffraction, which showed that both specimens were single phase. The materials crystallized in the space group P2 1 /n. Dilatometry revealed that material expands non‐linearly with the...
-
Digital Processing of Frequency–Pulse Signal in Measurement System
PublikacjaThe work presents the issue of the use of multichannel measurement systems of sensors processing input value to impulse signal frequency. The frequency impulse signal obtained from such sensors is often required to be processed at the same time with a voltage signal which is obtained from other sensors used in the same measurement system. In such case, it is usually necessary to sample the output signals from all sensors in the...
-
Analysis of Measurement Errors in Rail Vehicles’ Pantograph Inspection System
PublikacjaThe paper presents an approach to evaluation of height measurement errors in laser scanning inspection system. The system, consisting of a laser line generator and a specialized camera, is dedicated to diagnosing carbon contact strips of railway vehicles’ pantographs. While height measurement resolution is easily computable based on system parameters, determining the measurement error is troublesome due to numerous impacts. As...
-
Temperature influence on tyre/road noise of selected tyres
PublikacjaAir and road temperatures substantially affect road vehicle noise emission. The temperature influence on tyre/road noise depends mainly on tyre-road combination. It is different for dense and porous pavements, for bituminous and cement ones. It differs also depending on tyres. The correction procedures for temperature effect are still under consideration and preparation. Tyre/road noise measurements using CPX method were performed...
-
Novel Desorber for Online Drilling Mud Gas Logging
PublikacjaThis work presents the construction solution and experimental results of a novel desorber for online drilling mud gas logging. The traditional desorbers use mechanical mixing of the liquid to stimulate transfer of hydrocarbons to the gaseous phase that is further analyzed. The presented approach is based on transfer of hydrocarbons from the liquid to the gas bubbles flowing through it and further gas analysis. The desorber was...
-
Experimental and numerical investigation of mercury removal from flue gas by sorbent polymer composite
PublikacjaThis paper presents an experimental and numerical investigation of the performance of a sorbent polymer composite (SPC) material used for removing mercury from the flue gases in a full-scale industrial installation. The investigated material is an attractive alternative to activated carbon, which is commonly used for this purpose. While the application of the SPC is characterized by high capital expenditures, this technology offers...
-
Spectral measurement of birefringence using particle swarm optimization analysis
PublikacjaThe measurement of birefringence is useful for the examination of both technical and biological objects. One of the main problems is that the polarization state of light in birefringent media changes periodically. Without the knowledge of the period number, the birefringence of a given medium cannot be determined reliably. We propose to analyse the spectrum of light in order to determine the birefringence. We use a Particle Swarm...
-
Aleksandra Parteka dr hab. inż.
OsobyAbout me: I am an associate professor and head of doctoral studies at the Faculty of Management and Economics, Gdansk University of Technology (GdanskTech, Poland). I got my MSc degree in Economics from Gdansk University of Technology (2003) and Universita’ Politecnica delle Marche (2005), as well as MA degree in Contemporary European Studies from Sussex University (2006, with distinction). I received my PhD in Economics...
-
Temperature Sensors Based on Polymer Fiber Optic Interferometer
PublikacjaTemperature measurements are of great importance in many fields of human activities, including industry, technology, and science. For example, obtaining a certain temperature value or a sudden change in it can be the primary control marker of a chemical process. Fiber optic sensors have remarkable properties giving a broad range of applications. They enable continuous real-time temperature control in difficult-to-reach areas, in...
-
Nonlinear generation of non-acoustic modes by low-frequency sound in a vibrationally relaxing gas
PublikacjaTwo dynamic equations referring to a weakly nonlinear and weakly dispersive flow of a gas in which molecular vibrational relaxation takes place. are derived. The first one governs an excess temperature associated with the thermal mode, and the second one describes variations in vibrational energy. Both quantities refer to non-wave types of gas motion. These variations are caused by the nonlinear transfer of acoustic energy into...
-
Analytical method for calculation of heat source temperature drop for the Organic Rankine Cycle application
PublikacjaIn the paper presented are considerations on the cooperation of the limited capacity heat source with the Organic Rankine Cycle unit. Usually the heat source providing thermal energy to the Organic Rankine Cycle (ORC) may have twofold characteristics. It can be in the form of a single phase fluid, i.e. as hot exhaust gas or hot liquid, or in some cases it may be available as a phase changing fluid, as for example, technological...
-
FLOW MEASUREMENT AND INSTRUMENTATION
Czasopisma -
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT
Czasopisma -
Journal of Nursing Measurement
Czasopisma -
Journal of Applied Measurement
Czasopisma -
Modelling, Measurement and Control A
Czasopisma -
Performance Measurement and Metrics
Czasopisma -
APPLIED PSYCHOLOGICAL MEASUREMENT
Czasopisma -
Journal of Educational Measurement
Czasopisma -
Applied Measurement in Education
Czasopisma -
3D Monitoring - Identification of measurement problems at larger movements of the tracked points
PublikacjaAuthors identified the problems associated with the determination of the controlled points coordinates by use of automated Total Station placed behind transparent barrier. Important thing in the mentioned analysis was a large change of controlled points position and not stable Total Station’s stand (because of stand’s thermal drift). This two elements, combined with measurement made through glass plate determine the need for impact...
-
The evaluation of the vibration measurement usability of electronic indicator lemag "premet C"
PublikacjaThe measuring possibilities of modern compression and combustion pressure analyzers are extended with additional functions. One of them is parallel to the pressure measurement, the measurement of vibrations in the region of the cylinder head. The paper presents a general assessment of the vibration measurement function of the electronic indicator LEMAG "PREMET C". This feature is very rarely offered by manufacturers of these devices....
-
Instantaneous Heating and Cooling Caused by Periodic or Aperiodic Sound of Any Characteristic Duration in a Gas with Vibrational Relaxation
PublikacjaThermodynamic relaxation of internal degrees of a molecule's freedom in a gas occurs with some characteristic time. This makes wave processes in a gas behave differently depending on the ratio of characteristic duration of perturbations and the relaxation time. In particular, generation of the secondary non-wave modes by intense sound in a nonlinear flow dependens on frequency. These kinds of interaction are considered in this...
-
Spirometry measurement model - the diagnostic purpose support
Publikacjathe paper presents a new model of respiratory mechanism based on the spirometry measurements. the spirometry test assesses the efficiency of the lung ventilation. the respiratory system functioning is based on the ventilation mechanism. thus the quality of the lung depends on the quality of lung ventilation. modelling of the respiratory system supports a diagnostic process. the model parameter estimates are obtained on the basis...
-
HIGH TEMPERATURE HEAT PUMPS – PERSPECTIVE HEATING SYSTEMS?
PublikacjaIn the paper presented are authors own concepts of high temperature compressor heat pumps for the utilisation of medium and low temperature sources of heat. Working fluids for use in high temperature heat pumps are discussed, as well as the criteria for their selection. Analyses are presented for the production of in the upper steam source at 130 °C. One-stage systems and cascade systems were analyzed. An analysis of the coefficient...
-
OPTICAL STRAIN MEASUREMENT OF CONCRETE VERSUS MANUAL EXTENSOMETER MEASUREMENT BASED ON THE TEST RC DEEP BEAM IN A COMPLEX STATE OF STRESS
PublikacjaThe purpose of this study is to compare the strain measurement techniques of concrete in R-C element subjected to the monotonic load up to the failure. In the analysis manual extensometer methods of measurements and the optical system ARAMIS for non-contact three-dimensional measurements of deformation was used. The test sample was a cantilever deep beam loaded throughout the depth which was a part of the reinforced concrete deep...
-
Analysis of Vibration and Acoustic Signals for Noncontact Measurement of Engine Rotation Speed
PublikacjaThe non-contact measurement of engine speed can be realized by analyzing engine vibration frequency. However, the vibration signal is distorted by harmonics and noise in the measurement. This paper presents a novel method for the measurement of engine rotation speed by using the cross-correlation of vibration and acoustic signals. This method can enhance the same frequency components in engine vibration and acoustic signal. After...
-
Boron-Doped Diamond/GaN Heterojunction—The Influence of the Low-Temperature Deposition
PublikacjaWe report a method of growing a boron-doped diamond film by plasma-assisted chemical vapour deposition utilizing a pre-treatment of GaN substrate to give a high density of nucleation. CVD diamond was deposited on GaN substrate grown epitaxially via the molecular-beam epitaxy process. To obtain a continuous diamond film with the presence of well-developed grains, the GaN substrates are exposed to hydrogen plasma prior to deposition....
-
Photogrammetric and total station's measurement of compressed column's model
PublikacjaModelling studies continue to play an important role. One of such study is stress determination in the reinforcement bars of reinforced columns and determine column's axis deformation. The article presents measurements results of control points located on the model of reinforced concrete column. The column was compressed in few series till it's destruction. In this studies, photogrammetric method and total station measurements...
-
Electrocatalytic Gas Sensor with Reference Layer
PublikacjaThis paper presents studies of gas sensors prepared in ceramic technology with Nasicon as a solid electrolyte. Sensors work in the voltammetric mode thus based on the excitation of a sensor with a periodic potential signal while current response is recorded. The main aim is to investigate a Bi8Nb2O17 reference layer influence on sensor properties. Sensors I-V characteristics in different concentration of nitrogen dioxide have been...
-
Impact of high temperature drying process on beech wood containing tension wood
PublikacjaThe technology of high temperature drying has a great inuence on dimensional and selected physical changes in tension wood. Article is focused on the measurement properties such as moisture content, color changes and longitudinal warping. The quality of beech wood is determined based on structure and properties of wood, frequency of defects in wood material. The tension wood is considered as an important wood defect causing negative...
-
Evaluation of expanded uncertainty of instantaneous power measurement in a bearing diagnostic system.
PublikacjaThe paper presents the issues concerning the estimation of the expanded uncertainty in the system for the diagnosis of rolling bearings, consisting of transducers: voltage and current voltage, which is used for diagnostic bearing motors method based on the measurement and analysis of the instantaneous power signal consumed by the induction motor. It presents the methodology for assessing the measurement uncertainty and presents...
-
Inspection of Gas Pipelines Using Magnetic Flux Leakage Technology
PublikacjaMagnetic non-destructive testing methods can be classified into the earliest methods developed for assessment of steel constructions. One of them is the magnetic flux leakage technology. A measurement of the magnetic flux leakage is quite commonly used for examination of large objects such as tanks and pipelines. Construction of a magnetic flux leakage tool is relatively simple, but a quantitative analysis of recorded data is a...
-
Possibilities of Increasing the Overall Efficiency of Gas-steam CHP Microplant
PublikacjaThe paper presents ways to increase the efficiency of a gas-steam micro power plant by modifying the cycle combination. The modification consists in partial release of the fluid downstream of the gas turbine and using it for ORC fluid overheating and evaporation. Advantages of this solution over the simplest gas and steam cycles’ combination are demonstrated.
-
New concept of a measurement probe for high impedance spectrocopy
PublikacjaArtykuł przedstawia nową koncepcję sondy pomiarowej służącej jako obwód wejściowy analizatora do spektroskopii wysokoimpedancyjnej. Dzięki wykorzystaniu przetwornika prąd na napięcie uzyskano najmniejszy możliwy wpływ pojemności kabli dołączających mierzony obiekt na wynik pomiaru. Przeprowadzono analizę sondy biorąc pod uwagę najważniejsze parametry wpływające na dokładność pomiaru: pojemności pasożytnicze oraz rzeczywiste parametry...
-
Radio Link Measurement Methodology for Location Service Applications
PublikacjaThe aim of this paper is the methodology of measurements executed in a radio link for the realization of radiolocation services in radiocommunication networks, particularly in cellular networks. The main results of the measurements obtained in the physical layer of the universal mobile telecommunications system (UMTS) are introduced. A new method for the utilization of the multipath propagation phenomenon to improve the estimation...
-
Measurement microsystem for high impedance spectroscopy of anticorrosion coatings
PublikacjaW artykule przedstawiono mikrosystem do pomiarów bardzo dużych impedancji ukierunkowany na identyfikację parametrów powłok antykorozyjnych metodą spektroskopii impedancyjnej. Do wyznaczania składowych ortogonalnych sygnałów pomiarowych zastosowano w nim technikę cyfrowego przetwarzania sygnałów. Pozwoliła ona na uzyskanie szerokiego zakresu częstotliwości pomiarowych, zwłaszcza bardzo niskich, od ćHz, przy zachowaniu prostej konstrukcji...
-
Identification of volatile compounds based on the electrocatalytic gas sensor responses
PublikacjaMeasured response in case of electrocatalytic gas sensors is in form of a voltamperometric characteristic. Current-voltage (I-V) response shape depends on the gas type and its concentration. Such response contains significantly more information comparing with typical electrochemical sensors, but is quite difficult to analyze. When I-V curve contains current peaks, position of such peaks can be used...
-
Non-Contact Temperature Measurements Dataset
PublikacjaThe dataset titled The influence of the distance of the pyrometer from the surface of the radiating object on the accuracy of measurements contains temperature measurements using a selection of four commercially available pyrometers (CHY 314P, TM-F03B, TFA 31.1125 and AB-8855) as a function of the measuring distance. The dataset allows a comparison of the accuracy and measuring precision of the devices, which are very important...
-
Carbon dioxide sequestration during shale gas recovery
PublikacjaThis paper presents literature on theoretical and practical aspects of gas production from shale using carbon dioxide fracturing. Development of technical and environmental aspects of carbon dioxide fracturing technologies is also considered. Patents applicable to carbon dioxide fracturing are reviewed. There were also conducted researches to evaluate possibility of carbon dioxide sequestration in shale gas reservoirs.
-
Determination of binder-aggregate adhesion by contact angle measurement
PublikacjaThe key factor in asphalt pavement durability, especially in the presence of water, is adhesion of the bituminous binder to mineral aggregates. There are currently no standard laboratory test procedures that can quickly and accurately measure the strength of the interaction (bond) between the binder and aggregate. In this regard, to evaluate the adhesion force measurements based on the contact angle between the binder and the aggregate...
-
Mass transfer in Spinning Fluids Reactor — Measurement and prediction
PublikacjaSpecific mass transfer area (a) and overall volumetric mass transfer coefficient (kLa) are mass transfer parameters commonly used in the description and comparison of various chemical reactors’ constructions. Determination of these was performed for Spinning Fluids Reactor (SFR). Sodium sulfite oxidation in the presence of cobalt ion catalyst was used for the determination of a and kLa. The a and kLa were successful predicted....
-
Analysis of measurement uncertainty for contact-less method used to measure the position of catenary contact wire, performed with the use of Monte Carlo method
PublikacjaCurrently the majority of main railway lines in Europe are electrified, and electric trains have the biggest share in the entire amount of rail transport. Reliability of electrified railways is closely related to the issue of supplying traction vehicles with energy. The problems connected with diagnostics of energy consumption node, namely the contact line and the current collector, are therefore of fundamental importance for maintaining...
-
Security Assessment of a Turbo-Gas Power Plant
PublikacjaCritical infrastructures are exposed to new threats due to the large number of vulnerabilities and architectural weaknesses introduced by the extensive use of information and communication technologies. This paper presents the results of an exhaustive security assessment for a turbo-gas power plant.
-
Influence of High Temperature Oxidation on Hydrogen Absorption and Degradation of Zircaloy-2 and Zr 700 Alloys
PublikacjaThe present research was aimed at determining the effects of the oxide layers on hydrogen absorption, microstructure and mechanical properties of the Zircaloy- 2 and Zr 702 alloys. The oxidation was made at 350 °C, 700 °C and 900 °C for 10 to 30 min in laboratory air, followed by hydrogen cathodic charging for 72 h and annealing at 400 °C for 4 h. The slow strain rate tests were carried out on oxidized, charged and annealed specimens. The...
-
Measurement system based on USB Z-Wave controller
PublikacjaA wireless measurement system based on the Z-Wave standard is presented in this paper. The system is composed of a U SB Z-Stick Gen5 controller connected to a Personal Computer and a Fibaro controller FGRGBWM-441. Operation of the system is controlled by software written in C++ using OpenZWave library. Some metrological aspects of the system are evaluated: accuracy, linearity, resolution and frequency of voltage measurements.
-
Gas sensors based on conducting polymers-recent developments
PublikacjaThis work discusses sensing performance dependence of PEDOT polymer and its composites on the counter ions used in the polymerization process. The sensors based on PEDOT-RGO composite show reversible response to NO2, while on PEDOT/LiClO4 irreversible. As a result, PEDOT-RGO could be used as a typical gas sensor, while sensor based PEDOT/LiClO4 could be used as an integrating gas sensor, also known as an accumulating gas sensor....
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublikacjaIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Influence of temperature and nitrogen pressure on the test without active gases for high-temperature proton exchange membrane fuel cells
PublikacjaHigh-Temperature Proton-Exchange Membrane Fuel Cells (HT-PEMFCs) are a candidate for electrical energy supply devices in more and more applications. Most notably in the aeronautic industry. Before any use, an HT-PEMFC is preheated and after that supplied with its active gases. Only at this state, the diagnostics can be performed. A method of testing not requiring a complete start-up would be beneficial for many reasons. This article...