Filtry
wszystkich: 1659
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: BASE-ISOLATED BUILDINGS
-
Earthquake-Induced Pounding of Medium-to-High-Rise Base-Isolated Buildings
PublikacjaDuring earthquakes, out-of-phase vibrations in adjacent buildings with limited distance may cause pounding between them. In recent years, the use of seismic isolation has expanded considerably as an effective approach to reduce seismic damage. However, the isolated building experiences large displacements during earthquakes, and there is a possibility of collisions with adjacent structures. The research on earthquake-induced pounding...
-
Simulation of the response of base-isolated buildings under earthquake excitations considering soil flexibility
PublikacjaThe accurate analysis of the seismic response of isolated structures requires the incorporation of the flexibility of supporting soil. However, it is often customary to idealize the soil as rigid during the analysis of such structures. In the present paper, seismic response time history analyses of base-isolated buildings modelled as single degree-of-freedom (SDOF) and multi degree-of-freedom (MDOF) systems with linear and nonlinear...
-
The Effectiveness of Rubber Bumpers in Reducing the Effects of Earthquake-Induced Pounding between Base-Isolated Buildings
PublikacjaTh e methods for preventing earthquake-induced structural pounding between two adjacent buildings include ensuring a sufficient separation distance between them or decreasing their relative displacement during seismic excitation. Some equations or even specific values of such gap sizes between two buildings have been introduced so as to avoid collisions. Increasing the stiffness of buildings, using tuned mass dampers, applying...
-
Pounding-involved response of isolated and non-isolated buildings under earthquake excitation
PublikacjaCelem artykułu jest dokładna analiza zachowania się kolidujących ze sobą dwóch budynków z wibroizolacją i bez wibroizolacji poddanych obciążeniom dynamicznym podczas trzęsień ziemi. W analizie rozważno przypadki kiedy oba budynki mają wibroizolację, kiedy tylko jeden budynek ma wibroizolację oraz kiedy żaden z budynków nie ma wibroizolacji. Wyniki badań pokazują, iż budynki z wibroizolacją są bardziej podatne na zderzenia podczas...
-
Numerical evaluation of dynamic response of an experimentally tested base-isolated and fixed-base steel structure model
PublikacjaSeismic isolation is recognized as one of the most popular and effective methods of protecting structures during earthquake. The present paper is focused on the comparison be-tween the dynamic responses of buildings with fixed and isolated bases exposed to seismic exci-tations. The aim of the study is to investigate the effectiveness of a simplified base isolation numerical modelling technique using the linear springs. One-storey...
-
Numerical study on seismic response of a base-isolated building modelled with shell elements
PublikacjaSeismic isolation is counted among the most popular and effective means of protecting structures against earthquake forces. Base isolators, like Lead-Rubber Bearings (LRB), High-Damping Rubber Bearings (HDB) or Friction Pendulum Systems (FPS) are extensively used in practice in many earthquake-prone regions of the world. The present paper reports the results obtained from the numerical study on seismic response of a base-isolated...
-
Column base fixity in steel moment frames: Observations from instrumented buildings
PublikacjaThe rotational fixity of column base connections in Steel Moment Resisting Frames (SMRFs) strongly influences their seismic response. However, approaches for estimating base fixity have been validated only against laboratory test data. These approaches are examined based on strong motion recordings from four instrumented SMRF buildings in California to informbest practices for seismic response simulation. These buildings represent...
-
Effects of Column Base Flexibility on Seismic Response of Steel Moment-Frame Buildings
PublikacjaSteel Moment Resisting Frames (SMRFs) are very popular lateral load resisting systems in many seismically active regions. However, their seismic response is strongly dependent on the rotational fixity of column base connections. Despite many studies (both experimental and numerical) in this particular area, available approaches for estimating column base flexibility have been validated only against laboratory test data. In the...
-
Non-linear behaviour of base-isolated building supported on flexible soil under damaging earthquakes
PublikacjaSeismic isolation is a strategy to reduce damage of structures exposed to devastating earthquake excitations. Isolation systems, applied at the base of buildings, lower the fundamental frequency of the structure below the range of dominant frequencies of the ground motion as well as allow to dissipate more energy during structural vibrations. The effectiveness of the base-isolated buildings in damage reduction has been confirmed...
-
Finite-element analysis of a base-isolated multi-storey steel building under seismic motions
PublikacjaNumerical simulation of the seismic behaviour of a multi-storey steel building, both fixed-base and base-isolated, under the 1940 El Centro earthquake was performed in this paper. The analyzed 4-storey building was decoupled from the shaking ground with the Polymeric Bearings, which can be considered a proposal of a new seismic isolation system. It consists of rectangular-shaped blocks made of a specially prepared flexible polymeric...
-
Seismic Response of High-Rise Buildings Equipped with Base Isolation and Non-Traditional Tuned Mass Dampers
PublikacjaOne of the methods in structural control is the application of combinational control systems in order to reduce the response of structures during earthquakes. The aim of the present paper is to verify the effectiveness of a hybrid control strategy, combining base isolation and non-traditional tuned mass dampers (TMDs) (i.e., TMDs with dashpots directly connected to the ground) in suppressing structural vibrations of high-rise buildings....
-
Pounding between high-rise buildings founded on different soil types
PublikacjaEarthquake-induced pounding is a phenomenon that has been often experienced in previous earthquakes. The aim of this study is to investigate the effect of the soil type on high-rise buildings experiencing earthquake induced-pounding. Pounding between 7-storey and 9-storey buildings is examined under five soil types defined in the ASCE 7-10 code which are hard rock, rock, very dense soil and soft rock, stiff soil and soft clay soil....
-
Seismic pounding between adjacent buildings: Identification of parameters, soil interaction issues and mitigation measures
PublikacjaStructural pounding has been observed in many previous earthquakes due to insufficient gap commonly provided between adjacent structures. The collisions usually generate large impact forces and short duration acceleration pulses which may result in significant damage to the colliding buildings. Because of that, earthquake induced structural pounding has been intensively studied and investigated for the last three decades. Results...
-
Effect of soil on the capacity of viscous dampers between adjacent buildings
PublikacjaThis study investigated the seismic pounding of two adjacent buildings considering soil–structure interaction (SSI). A comprehensive parametric study of buildings with different heights was performed to reveal the pounding-involved behaviour considering the soil effect. Wavelet transform has been conducted to gain insight into the differences in the frequency contents of the impact forces between fixed- and flexible-base adjacent...
-
The role of isolated farmsteads in the open landscape protection on the example of Kashubia
PublikacjaAs a result of the social and economic transformation of rural areas, open landscapes are disappearing. Former farmsteads are being devastated or beginning to lose their landscape context due to the spread of residential building development. At the same time, in many places, the farmstead form is clearly legible and remains an element with which the view is structured and enriched. The article was aimed at drawing attention to...
-
Application of soil nailing technique for protection and preservation historical buildings
PublikacjaSoil nailing is one of the recent in situ techniques used for soil improvement and in stabilizing slopes. The process of soil nailing consists of reinforcing the natural ground with relatively small steel bars or metal rods, grouted in the pre-drilled holes. This method has a wide range of applications for stabilizing deep excavations and steep slopes. Soil nailing has recently become a very common method of slope stabilisation...
-
The Importance of Contextual Topology in the Process of Harmonization of the Spatial Databases on Example BDOT500
PublikacjaIn this work, we present two detailed problems of topological errors in spatial database. Both issues are inconsistencies in the database, i.e. interior topological relationships layers of buildings and the relationship between the buildings layer and the layer of plots. That inconsistency is related to the residual polygons that arise as a result of overlapping objects, or gaps between objects. The occurrence of this type of error...
-
Behaviour of Colliding Multi-Storey Buildings under Earthquake Excitation Considering Soil-Structure Interaction
PublikacjaThis paper investigates the coupled effect of the supporting soil flexibility and pounding between neighbouring, insufficiently separated buildings under earthquake excitation. Two adjacent three-storey structures, modelled as inelastic lumped mass systems with different structural characteristics, have been considered in the study. The models have been excited using the time history of the Kobe earthquake of 1995. A nonlinear...
-
Earthquake-induced pounding between equal height multi-storey buildings considering soil-structure interaction
PublikacjaThe present paper investigates the coupled effect of the supporting soil flexibility and pounding between neighbouring, insufficiently separated equal height buildings under earthquake excitation. Two adjacent three-storey structures, modelled as inelastic lumped mass systems with different structural characteristics, have been considered in the study. The models have been excited using a suit of ground motions with different peak...
-
Behaviour of Asymmetric Structure with Base Isolation Made of Polymeric Bearings
PublikacjaEarthquake-induced ground motions are the most severe and unpredictable threats to the structures all around the world. Seismic excitations cause a lot of damage in a wide variety of ways, leaving thousands of casualties in their wake. Due to randomness of earthquake occurrence, lack of visible causes and their power of destructiveness, structural engineers need to develop new technical solutions and protection systems against...