Filtry
wszystkich: 10898
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: DIFFERENTIAL IMPEDANCE ANALYSIS
-
Differential analysis of impedance data
Publikacja -
Polynomial analysis as a new way of describing dynamic impedance spectra – Differential and relative impedance spectra
PublikacjaModel measurements of an equivalent electrical system were carried out using the technique of Dynamic Electrochemical Impedance Spectroscopy. The measurement took the form of potentiodynamic changes imposed on the tested system. Using the possibility of continuous impedance measurements, an attempt was made to develop an original and innovative method of analyzing impedance spectrograms, which is termed polynomial analysis. As...
-
Differential analysis of dynamic immittance spectra
PublikacjaThis work presents a new approach to the analysis of immittance spectrograms of systems characterised by non-stationarity. The possibility of linking the evolution of the immittance response with changes in the parameters describing the system is achieved by introducing a spectrum in differential form. By using the above procedure, it becomes possible to separate elements with a dependence (or lack thereof) from an independent...
-
The amplitude analysis of impedance spectra
Publikacja -
Platform Supporting the Esophageal Impedance Analysis
PublikacjaThe esophageal pH-impedance examination is one of the most popular diagnostic methods for identifying the upper gastrointestinal tract’s diseases. Inconclusive test evaluation criteria makes it difficult to state the definite diagnosis. In this paper, the computer platform supporting the research and teaching process in the area of pH-impedance analysis is presented. Users, having a variety of mathematical and statistical methods...
-
A Comprehensive Analysis of Impedance of the Electrochemical Cell
PublikacjaA comprehensive impedance characteristics of two electrodes electrochemical cell has been pre sented. In this method a multisinusoidal current excitation signal is used. The change of potential of both the electrodes are all registered as a function of time. The proposed method gives the possibility of determining the impedance of both electrodes individually as well as the impedance of a twoelectrode system. Additional application...
-
Polynomial description of dynamic impedance spectrogram—introduction to a new impedance analysis method
PublikacjaThis paper presents a polynomial description of spectrograms obtained using Dynamic Electrochemical Impedance Spectroscopy. A method to fit the polynomial degree correctly is discussed. A simple electrical system of a diode connected in parallel with a capacitor was used for testing. Dynamic impedance measurements during potentiodynamic polarization were conducted. This paper presents an alternative analysis method that allows...
-
Mesoscopic impedance analysis of solid materials surface
PublikacjaSeveral techniques have been developed in order to characterize electrical properties of surfaces in micrometer/nanometer scale. Obtaining of the spatial distribution of sample resistance, capacitance or potential requires separate measurements performed in different scanning modes. On the other hand, analysis of the frequency response of investigated system enables determination of several physical quantities in single measurement...
-
Mesoscopic impedance analysis of solid materials’ surface
Publikacja -
A metrological analysis of the input circuit of an impedance meter.
PublikacjaW pracy przeprowadzono analizę obwodu wejściowego miernika impedancji W analizie obwodu wejściowego, uwzględniono najważniejsze czynniki wpływające na sygnały na jego wejściu: parametry zmiennoprądowe zastosowanych wzmacniaczy, rezystancję zakresową przetwornika prąd-napięcie, pojemności montażowe. Przeprowadzono symulację sygnałów wydzielanych w obwodzie dla różnych wartości pojemności pasożytniczych, następnie dokonano badań...
-
Stochastics and Partial Differential Equations-Analysis and Computations
Czasopisma -
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublikacjaW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwości od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...
-
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublikacjaW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwosci od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...
-
An integral-differential method for impedance determination of the hydrogen oxidation process in the presence of carbon monoxide in the proton exchange membrane fuel cell
PublikacjaThe impedance of a proton exchange membrane fuel cell powered by hydrogen contaminated with carbon monoxide, ranging from 150 to 300 ppb, is measured and discussed. The tested range of CO concentration complied with the fuel standard specified in the ISO standards. Studies of influence of CO contamination on operation of PEMFC are crucial for further development and commercialization of fuel cells for automotive applications. Based...
-
Errors analysis of differential single-frequency geo-positioning algorithm
Publikacja -
Analysis of Positioning Error and Its Impact on High Frequency Performance Parameters of Differential Signal Coupler of Differential Signal Coupler
PublikacjaThis paper presents the analysis of the effect of differential signal coupler positioning accuracy on its high frequency performance parameters for contact-less high speed chip-to-chip data transmission on PCB application. Our considerations are continuation of the previous works on differential signal coupler concept, design methodology and analysis for high speed data transmission monitoring presented in [1, 2]. The theoretical...
-
Analysis of thoracic regional impedance changes using PCA approach
PublikacjaA multichannel impedance and one lead electrocardiographic recording system has been developed. The impedance measurement unit is built using a four-electrode technique. It consists of a sinusoidal, 40 kHz, current source and five measurement channels. Circumferential current electrodes have been located at a neck and an abdomen. Voltagemeasurement disk electrodes formed five two-electrode measurement ports. The impedance change...
-
An Application Supporting Gastroesophageal Multichannel Intraluminal Impedance-pH Analysis
PublikacjaDue to a significant rise in the number of patients diagnosed with diseases of the upper gastrointestinal tract and the high cost of treatment, there is a need to further research on one of the most popular diagnostic tests used in this case – esophageal Multichannel Intraluminal Impedance and pH measurement. This may lead to finding new diagnostically relevant information, used to quicken and improve the diagnostic procedure....
-
A complete impedance analysis of electrochemical cells used as energy sources
PublikacjaA comprehensive description of impedance ofelectrochemical systems has been presented, along withthe assumptions of the method used. In this method, amultisinusoidal current excitation signal is used. Thechanges of potential of both the electrodes and thepotential difference between these electrodes are allregistered simultaneously as a function of time. Theproposed method offers the possibility of separatelydetermining the instantaneous...
-
Impedance analysis of Portevin-Le Chatelier effect on aluminium alloy
PublikacjaW niniejszej pracy przeprowadzono badania elektrochemiczne powierzchniowego efektu PLC, związanego z nierównomiernym procesem płynięcia plastycznego stopów aluminium zawierających magnez. Występujący efekt PLC w postaci serration wywołuje niehomogeniczny proces zmian zewnętrznej powierzchni rozciąganej próbki. Wykonano badania metodą Dynamicznej Spektroskopii Impedancyjnej w warunkach dynamicznych prowadzenia procesu rozciągania....
-
Impedance analysis of Portevin-Le Chatelier effect on aluminium alloy
Publikacja -
Reliability Analysis of Data Storage Using Survival Signature and Logic Differential Calculus
PublikacjaThe Data storage system is an important part of any information system. All the necessary data that must be available for the successful operation of the information system are stored here. Therefore, it is advisable to think about the reliability of such a data storage system. As part of reliability engineering, it is possible to perform a reliability analysis of any system. Therefore, the data storage system can be analyzed as...
-
Physics-guided neural networks (PGNNs) to solve differential equations for spatial analysis
PublikacjaNumerous examples of physically unjustified neural networks, despite satisfactory performance, generate contradictions with logic and lead to many inaccuracies in the final applications. One of the methods to justify the typical black-box model already at the training stage and lead to many inaccuracies in the final applications. One of the methods to justify the typical black-box model already at the training stage involves extending...
-
Stability analysis of two-step Runge-Kutta methods for delay differential equations
PublikacjaW pracy badana jest własność stabilności dwukrokowej metody Rungego-Kutty względem liniowego równania testowego o zespolonych współczynnikach. Udowodniono, że jeśli pewne warunki są spełnione to każda A-stabilna dwukrokowa metoda Rungego-Kutty zastosowana do równania różniczkowego z opóźnieniem jest P-stabilna.
-
Advancing electrochemical impedance analysis through innovations in the distribution of relaxation times method
PublikacjaElectrochemical impedance spectroscopy (EIS) is widely used in electrochemistry, energy sciences, biology, and beyond. Analyzing EIS data is crucial, but it often poses challenges because of the numerous possible equivalent circuit models, the need for accurate analytical models, the difficulties of nonlinear regression, and the necessity of managing large datasets within a unified framework. To overcome these challenges, non-parametric...
-
Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis
PublikacjaStarvation, flooding, and dry‐out phenomena occur in polymer electrolyte membrane fuel cells (PEMFCs), due to heterogeneous local conditions, material inhomogeneity, and uneven flow distribution across the single cell active area and in between the individual cells. The impact of the load level and air feed conditions on the performance was identified for individual single cells within a 10‐cell stack. Analysis of the current density...
-
Identification of the mechanical properties of the skin by electromechanical impedance analysis of resonant piezoelectric actuator
PublikacjaThis paper is devoted to the analysis and verification of developed piezoelectric sensor/actuator for measuring the mechanical properties of soft tissues, especially human skin. The key element of the measurement structure is an electromechanical system that uses both the reverse piezoelectric effect (vibration generation – stimulation of the tissues in the appropriate frequency range) and direct piezoelectric effect (system response...
-
Application of Galvanostatic Non-Linear Impedance Spectroscopy to the Analysis of Metallic Material Degradation
PublikacjaThis study presents a novel application of Non-Linear Electrochemical Impedance Spectroscopy (NLEIS) in galvanostatic mode for the rapid, non-destructive assessment of metal degradation. By using galvanostatic mode instead of traditional potentiostatic methods, polarization-related challenges are mitigated, enabling more accurate and reliable analysis. The technique allows for the determination of corrosion rates (corrosion current)...
-
Analysis of positioning error and its impact on high frequency properties of differential signal coupler
PublikacjaThis paper presents the analysis of the effect of differential signal coupler positioning accuracy on its high frequency performance parameters for contact-less high speed chip-to-chip data transmission on PCB application. Our considerations are continuation of the previous works on differential signal coupler concept, design methodology and analysis for high speed data transmission monitoring. The theoretical analysis of possible...
-
Theoretical and computational analysis of nonlinear fractional integro-differential equations via collocation method
Publikacja -
Transcriptomics in Toxicogenomics, Part II: Preprocessing and Differential Expression Analysis for High Quality Data
Publikacja -
Multivariate analysis of impedance data obtained for coating systems of varying thickness applied on steel
PublikacjaElectrochemical impedance spectroscopy (EIS) has proven to be a valuable test method for the electrochemical characterization of protective coatings on metals. The common way of analysis in impedance spectroscopy is to model the impedance spectrum by means of an equivalent circuit and to extract the quantity of interest using optimization techniques. A model, corresponding to the behavior of the sample under testing, is important...
-
Multispectral impedance quality testing of coil-coating system using principal component analysis
PublikacjaThe task of quality checking of the coil-coated system was undertaken using impedance spectroscopy. In order to properly characterize the system the new impedance spectrum was calculated as an averaged result of 12 experimental spectra obtained from 12 different places of the sample at the same time of immersion in 3% of NaCl. The experimental spectra were recorded for a 24-h period at 1 h intervals between starting points of each...
-
Cyclic analysis of thermal impedance of a passive layer of aluminium in a neutral borate buffer solution
PublikacjaW pracy przedstawiono wyniki badań warstwy pasywnej tworzącej się na stopie 1050 A w warunkach zmieniającej się temperatury. Zmiany realizowano w sposób cykliczny zwiększając a następnie zmniejszając temperaturę. W czasie zmian temperatury prowadzono badania metodę dynamicznej elektrochemicznej spektroskopii impedancyjnej. Stwierdzono największe zmiany parametrów elektrycznego schematu zastępczego w czasie pierwszego cyklu zmian....
-
Performance analysis of power swing blocking feature in ABB 670 series impedance relays
PublikacjaThis paper presents test results of a distance protection’s PSD power swing detection feature in ABB 670 series relays. A RED670 relay was tested, which is part of the hydroelectric set protection in Żarnowiec Pumped Storage Plant. The power swing blocking feature’s performance was analysed on the basis of the results of object tests made with an Omicron digital tester. Also presented are simulation results that illustrate the...
-
Discrimination of hospital isolates of Acinetobacter baumannii using repeated sequences and whole genome alignment differential analysis
PublikacjaAn optimized method for bacterial strain differentiation, based on combination of Repeated Sequences and Whole Genome Alignment Differential Analysis (RS&WGADA), is presented in this report. In this analysis, 51 Acinetobacter baumannii multidrug-resistance strains from one hospital environment and patients from 14 hospital wards were classified on the basis of polymorphisms of repeated sequences located in CRISPR region, variation...
-
Explicit difference schemes for nonlinear differential functional parabolic equations with time dependent coefficients - convergence analysis
PublikacjaW pracy wykazano zbieżność metody różnicowej dla zagadnienia początkowego dla równania parabolicznego bez pochodnych mieszanych, ze współczynnikami zależnymi od czasu, z nieliniową i nielokalną prawą stroną równania.
-
Instantaneous Impedance Analysis of Non-Stationary Corrosion Process: a Case Study of Carbon Steel in 1M HCl
PublikacjaThe paper concerns the problem of evaluation of stationarity of carbon steel corrosion in 1M HCl. Comparison of corrosion rate with addition of corrosion inhibitor to the reference measurement is the most often used way of evaluating inhibitor efficiency. Such an approach is valid only if corrosion rate is a stationary process. Two complementary techniques were used simultaneously: volumetric analysis of evolved hydrogen and instantaneous...
-
Stress Assessment of a Steel Bullet LPG Tank Under Differential Settlement Based on Geodetic Measurements and Sensitivity Analysis
PublikacjaThis paper presents an analysis of a steel bullet LPG tank in operation at a base in Poland. The structure was set on a sand-gravel pillow and rigid concrete slab, and its settlement was periodically measured at five measuring points along the structure. After a few years, differential settlement was observed. Based on geodetic data, we attempt to assess the current stress level in the structure. The proposed methodology uses a...
-
The suitability of DNA extracted from formalin-fixed, paraffin-embedded tissues for double differential polymerase chain reaction analysis
Publikacja -
Determining the Behavior of Water in Buttermilk Cheese with Polymerized Whey Protein Using Differential Scanning Calorimetry and Nuclear Magnetic Resonance Analysis
Publikacja -
The effect of strain rate on the passive layer cracking of 304L stainless steel in chloride solutions based on the differential analysis of electrochemical parameters obtained by means of DEIS
PublikacjaOkreślono wpływ szybkości rozciągania w zakresie 10-5s-1 ÷ 16∙10-5s-1 na niestacjonarny proces elektrochemiczny pękania warstwy pasywnej. Badania przeprowadzono na stali wysokostopowej 304L w temperaturze pokojowej w środowisku chlorków za pomocą dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS). W rezultacie uzyskano zestaw chwilowych widm impedancyjnych odzwierciedlających dynamikę badanego układu korozyjnego....
-
Corrosion behaviour of low carbon steel in artificial seawater using TP, LP, EIS, Harmonic Analysis (HA) and new method Dynamic Electrochemical Impedance Spectroscopy (DEIS)
PublikacjaZe względu na istotną rolę technik elektrochemicznych w badaniach procesów korozyjnych są one szeroko stosowane w monitorowaniu korozji. Celem niniejszej pracy jest zgromadzenie rezultatów wyników doświadczalnych uzyskanych różnymi technikami i znalezienie korelacji między nimi. Własności korozyjne stali stopowej (AISI 1026) w sztucznej wodzie morskiej zostały zbadane z wykorzystaniem ekstrapolacji tafelowskiej (TP), polaryzacji...
-
Efficient optimization approaches for microwave assisted extraction of high-quality antioxidant compounds from Salvia officinalis L.: UHPLC-HRMS differential analysis of phenolic profiles obtained by ultrasound and microwave extraction
PublikacjaThe study aims to optimize MAE of total phenolic compounds (TPC) and antioxidant capacity from Salvia officinalis L. leaves using a definitive screening design (DSD) and I-optimal design. UHPLC-HRMS analysis was used to identify and compare the composition of MAE and UAE optimal extracts. The results showed that DSD and I-optimal design were successfully applied for the optimization of MAE targeting phenolics and other antioxidants...
-
Distribution of Relaxation Times analysis results of impedance measured in function of temperature on porous SrTi0.50Fe0.50O3-d oxygen electrode sintered at 800 °C
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at 800 °C. Electrochemical impedance spectroscopy were measured at 800 °C; 750 °C and 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof. Ciucci’s group, was used...
-
Distribution of Relaxation Times analysis results of impedance measured in function of temperature on porous SrTi0.30Fe0.70O3-d oxygen electrode sintered at 800 °C
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. Electrochemical impedance spectroscopy were measured at 800 °C; 750 °C and 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof. Ciucci’s group, was used...
-
Distribution of Relaxation Times analysis results of impedance measured in function of temperature on porous SrTi0.65Fe0.35O3-d oxygen electrode sintered at 800 °C
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at 800 °C. Electrochemical impedance spectroscopy were measured at 800 °C; 750 °C and 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof. Ciucci’s group, was used...
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....