Filtry
wszystkich: 592
Wyniki wyszukiwania dla: DISTANCE MEASUREMENTS
-
New Indoor Positioning Algorithm for Distance Measurements
PublikacjaIn the paper a new indoor positioning algorithm is presented. This algorithm takes into account selected features of radio wave propagation in indoor environment. This results in improvement in accuracy of calculated position estimates. A comparative analysis of this new algorithm with Chan and Foy algorithms was made and described in the paper. This comparative analysis was made with utilization of real radio distance measurements.
-
The issue of uncertainty of visual measurement techniques for long distance measurements based on the example of applying electric traction elements in diagnostics and monitoring
PublikacjaRail transport is the most economical and energy-effective in the field of land transport, in particular electrified. In order to ensure efficient and reliable operation of electrified rail transport, the issues of monitoring and diagnostics of the traction infrastructure and vehicles are extremely important. The most critical point in the transmission of electric energy to the vehicle is the sliding contact of the current collector...
-
The influence of the distance of the pyrometer from the surface of the radiating object on the accuracy of measurements
Dane BadawczeDuring the COVID-19 epidemic, non-contact body temperature measurement has become very important. This dataset contain results of measurements of the four professional commercially available pyrometers. The CHY 314P, TM-F03B, TFA 31.1125 and Abatronic AB-8855 where tested in function of measuring distance from the surface of the radiating black body....
-
Examination method of the effect of the incidence angle of laser beam on distance measurement accuracy to surfaces with different colour and roughness
PublikacjaInterest in the influence of the incidence angle of a laser beam to distance measurements can be seen in many areas of science and technology: geodesy, glaciology, archaeology, machine automation, and others. This paper presents results of measurements of the effect of the incidence angle of a laser beam to distance measurements to the surfaces of different colour and roughness by Topcon's electro-optical total station with an...
-
Non-Contact Temperature Measurements Dataset
PublikacjaThe dataset titled The influence of the distance of the pyrometer from the surface of the radiating object on the accuracy of measurements contains temperature measurements using a selection of four commercially available pyrometers (CHY 314P, TM-F03B, TFA 31.1125 and AB-8855) as a function of the measuring distance. The dataset allows a comparison of the accuracy and measuring precision of the devices, which are very important...
-
A PROPOSAL FOR ONE-IMAGE PHOTOGRAMMETRY SYSTEM FOR MEASURING THE CLEARANCE DISTANCE. CASE STUDY
PublikacjaMeasurement of the clearance distance (both in the context of the rail and road) is one of the current and increasingly discussed topics in the context of photogrammetric and image processing (computer vision) methods. The article presents a description of a simple and rapid method of measure the clearance distance between the obstacles by using one-image photogrammetry. The proposed method was tested for the railway, tram and...
-
Measurements of Path Loss in Off-Body Channels in Indoor Environments
PublikacjaThis paper presents a measurements of the path loss for validation of a statistical model for off-body radio channels in an indoor multipath environment, which considers the distance dependent mean path loss, and describes body shadowing and fast fading components in a statistical way. The measurement equipment and propagation indoor environment have been presented. Two different bodies and five static and two walking scenarios...
-
Radio Channel Measurements in 868 MHz Off-Body Communications in a Ferry Environment
PublikacjaIn this paper, a characterization of the 868 MHz off-body radio channel in BANs is presented. Measurements were carried out in a ferry environment using a specific set-up. A method for path loss using radio distance measurements (RDMs) was developed. It allows to automate the measurements process and make it independent from the variable speed of a moving person. Based on the observed path loss as a function of distance, the obtained...
-
Tracking body movement for radio channel measurements in BAN with indoor positioning system
PublikacjaThis paper presents indoor positioning system based on inertial navigation with additional distance measurements using UWB modems and map matching to increase accuracy and eliminate position drift. Such system may be used to track position of human body during radio channel measurements for body area networks. Performance of proposed system and limitations caused by inertial navigation are briefly described.
-
HYDROACOUSTIC NOISE MEASUREMENTS
PublikacjaThe paper deals mainly with investigation of underwater noise that propagation is in shallow water. In this paper has been presented the experimental investigation results concerning the distribution of the sound field pressure generated by moving ships in the shallow water at the small distance from the ship. The main acoustical characteristics describing features of the field are spectrograms in pseudo 3D system – distance and frequency...
-
The hydrodynamic pressure field of the ship Zodiak, measurements and calculations
PublikacjaThe article presents the results of measurements of the slowly changing hydrodynamic pressure field HPF generated by the movement of the ship, Zodiak, in the Bay of Gdansk. The measurement results have been obtained in the framework of the program of the work in Siramis, under the auspices of the European Defence Administration of the EU, by the research team of the Naval Academy in Gdynia. The measurement results were compared with...
-
Measurement of distance, velocity and angle of arrival using FMCW-CW combined waveform
PublikacjaA procedure of tacking small flying object based on a general principle of FMCW and Doppler radar is presented. In order to increase measurement range, this technique uses active signal source on the moving object. For simultaneous measurements of distance, radial velocity and direction (AoA) as well as simplified synchronization a combined FMCW-CW waveform is proposed. The presented measurement system was realized and verified...
-
Distance measurement by the low coherent interferometer
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement errors in silent FM-CW sonar with matched filtering
PublikacjaThe secretiveness of sonar operation can be achieved by using continuous frequency-modulated sounding signalswith reduced power and significantly prolonged repeat time. The application of matched filtration in the sonarreceiver provides optimal conditions for detection against the background of white noise and reverberation, and avery good resolution of distance measurements of motionless targets. The article shows that target...
-
Comparison of new position estimation algorithm for indoor environment
PublikacjaIn the paper a new position estimation algorithm based on distance measurements is presented. This algorithm is dedicated for indoor environments. In the paper the new algorithm is compared with Chan algorithm. For the comparison were used real measurements conducted inside a building.
-
Examining Impact of Speed Recommendation Algorithm Operating in Autonomous Road Signs on Minimum Distance between Vehicles
PublikacjaAn approach to a new kind of recommendation system design that suggests safe speed on the road is presented. Real data obtained on roads were used for the simulations. As part of a project related to autonomous road sign development, a number of measurements were carried out on both local roads and expressways. A speed recommendation model was created based on gathered traffic data employing the traffic simulator. Depending on...
-
Long Distance Vital Signs Monitoring with Person Identification for Smart Home Solutions
PublikacjaAbstract— Imaging photoplethysmography has already been proved to be successful in short distance (below 1m). However, most of the real-life use cases of measuring vital signs require the system to work at longer distances, to be both more reliable and convenient for the user. The possible scenarios that system designers must have in mind include monitoring of the vital signs of residents in nursing homes, disabled people, who...
-
Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
PublikacjaIn this article a novel method of positional data integration in an indoor hybrid localization system combining inertial navigation with radio distance measurements is presented. A point of interest is the situation when the positional data and the radio distance measurements are obtained from less than thee reference nodes and it is impossible to unambiguously localize the moving person due to undetermined set of positional equations....
-
Geospatial Coverage and Signal Quality Measurements of Terrestrial DAB+ Network in Northern Poland
PublikacjaModern signal coverage maps are prepared based on industry-standard radio propagation models, which take into account a number of parameters, including: type of antenna, distance from the transmitter, type of terrain, etc. However, such simulations are prone to location-specific inaccuracies, and should be verified with in-situ measurements. This paper presents results of a field test of a terrestrial DAB+ (Digital Audio Broadcasting...
-
Analysis of Accuracy of Modified Gradient Method in Indoor Radiolocalisation System
PublikacjaIn this paper a new method, called modified gradient method, has been proposed for position calculation on the basis of distance measurement in indoor environment. It is shown that well known method of position calculation such as Foy is inefficient in indoor environment. In this article is also described the indoor radiolocalisation system which was used for collecting distance measurements which were employed for further comparative...
-
Local electrochemical impedance spectroscopy in dynamic mode of galvanic coupling
PublikacjaA novel method that combines local electrochemical impedance spectroscopy and mapping in dynamicmode is proposed. Method was validated over two galvanic couplings, namely zinc/copper and cad-mium/copper. Impedance spectrum response for all measuring points was obtained by means ofsimultaneous implementation of selected range of frequencies. Proposed method allows the measure-ment in a more time-efficient manner, at the same time...
-
A novel concept for tissue-metal detection and differentiation using an inductive proximity sensor
PublikacjaIn this paper a novel application of inductive proximity sensors for detection of living tissue by means of measurements of the coil impedance changes at different frequencies is described. The mathematical analyses utilizing Bessel function estimation include detected object size and its distance from a sensor. The main aim of this study is to prove the possibility of distinguishing between metal objects and living tissues. The...
-
Radio Channel Measurements in Body-to-Body Communications in Different Scenarios
PublikacjaThis paper presents body-to-body radio channel measurements at the 2.45 GHz band, for different body motion scenarios and on-body antenna placements, and both indoor and outdoor environments. Measurement equipment, investigated scenarios and considered environments are described, an initial analysis of results being presented. The mean path loss and the standard deviation depend on the mutual location of transmitting and receiving...
-
Radio Channel Measurements in Body-to-Body Communications in Different Scenarios
PublikacjaThis paper presents body-to-body radio channel measurements at the 2.45 GHz band, for different body motion scenarios and on-body antenna placements, and both indoor and outdoor environments. Measurement equipment, investigated scenarios and considered environments are described, an initial analysis of results being presented. The mean path loss and the standard deviation depend on the mutual location of transmitting and receiving...
-
Performance comparison of new modified gradient algorithm and Foy algorithm for iterative position calculation
PublikacjaIn the paper a new position calculation algorithm is presented. It is proposed for indoor environments and is called modified gradient algorithm. This algorithm is compared with well-known Foy algorithm. The comparative analysis is based on real distance measurements conducted in indoor environment.
-
Path Loss Measurements in Wideband Radio Link Designed for Maritime Environment
PublikacjaIn the article, the research and analysis of path loss in designed and evaluated digital radio link for high-speed data transmission in maritime environment is presented. Collected samples of received signal were used to determine the mean path loss and its standard deviation. Measuring campaign was carried out in a real maritime conditions. The mean value of path loss reached 126 dB on a distance of 11.16 km.
-
New Method for Increasing Precision of Position Estimation of a Moving Person in Hybrid Inertial Navigation System
PublikacjaIn this article a new method for increasing precision of position estimation of inertial navigation in hybrid localization system with reduced number of reference nodes for radio distance measurements is presented. Measuring tests were carried out to verify precision of position estimation of moving person in indoor environment.
-
Long-distance quantum communication over noisy networks without long-time quantum memory
PublikacjaThe problem of sharing entanglement over large distances is crucial for implementations of quantum cryptography. A possible scheme for long-distance entanglement sharing and quantum communication exploits networks whose nodes share Einstein-Podolsky-Rosen (EPR) pairs. In Perseguers et al. [Phys. Rev. A 78, 062324 (2008)] the authors put forward an important isomorphism between storing quantum information in a dimension D and transmission...
-
Transmission measurements between two geometrically small Vivaldi antennas performed in non-anechoic propagation conditions
Dane BadawczeThe dataset contains unprocessed measurements of complex transmission (and reflection) characteristics obtained in non-anechoic regime for a geometrically small, broadband spline-parameterized Vivaldi structure. The measurement setup comprises two Vivaldi antennas with the same topology where one is used as a reference structure, and another one as...
-
Analysis of Position Calculating Methods in Indoor Environment
PublikacjaIn the paper a modified gradient method has been proposed for position calculation on basis of distance measurement in indoor environment. It is shown that the well-known Chan method of position calculation is inefficient in indoor circumstances. Author presents Chan and modified gradient methods and achieved results for each one for real measurements.
-
Radio Link Measurement Methodology for Location Service Applications
PublikacjaThe aim of this paper is the methodology of measurements executed in a radio link for the realization of radiolocation services in radiocommunication networks, particularly in cellular networks. The main results of the measurements obtained in the physical layer of the universal mobile telecommunications system (UMTS) are introduced. A new method for the utilization of the multipath propagation phenomenon to improve the estimation...
-
New Method for Increasing Precision of Position Estimation in Hybrid Inertial Navigation System
PublikacjaIn article new method for increasing precision of position estimation by using inertial navigation in hybrid localization system with reduced number of reference nodes for radio distance measurements was presented. Measuring campaign using developed measuring stand were carried out to verify precision of position estimation of moving person in indoor environment.
-
A Wideband Channel Model for Body Area Networks in Circular Metallic Indoor Environments
PublikacjaIn this paper, the wideband characterization of the propagation channel in circular metallic indoor environments is addressed, regarding Body Area Networks and 5G small cells, an analytical model for the dependence of the mean delay and the average delay spread on the circle radius, the working frequency and the distance between the transmitter and the receiver being proposed. The derivation of the model is initially done analytically,...
-
Amplitude-distance spectroscopy in semi-contact mode
Dane BadawczeSince it was invented by Binnig et al. in 1986, atomic force microscopy (AFM) plays a key role in science and technology at the nanoscale. AFM is a microscopic technique that visualizes the surface topography using the attractive and repulsive forces of interaction between several atoms (in theory) of a blade attached to the end of the probe lever and...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um.
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement by the low coherent interferometer with NND layer (the source wavelegth 1310 nm)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...