Wyniki wyszukiwania dla: MEASUREMENT
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 200 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-0optic sensor - 250 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 210 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 300 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 270 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 190 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 260 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 290 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 170 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 280 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 150 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 230 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 240 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
A New Approach to Capacitive Sensor Measurements Based on a Microcontroller and a Three-Gate Stable RC Oscillator
PublikacjaA complete smart capacitive sensor solution basedA complete smart capacitive sensor solution based on a microcontroller was developed. This approach includes the development of both the hardware and software. The hardware part comprises an 8-bit microcontroller equipped with two timers/counters and a three-gate stable RC relaxation oscillator. The software part handles system configuration, measurement control, communication control,...
-
A numerical and experimental analysis of multi-hole orifice in turbulent flow
PublikacjaIn this research study, the comprehensive metrological analysis is investigated for a 4-hole orifice with module m = 0.25 installed in the pipeline with an internal diameter of 50 mm. A detailed numerical simulation was performed for the turbulence models: k-ε-realizable and k-ω-BSL. The novelties of the research include model validation by comparing the results of numerical studies with the experiment conducted in the area of...
-
Current divider-based nanosecond high current pulse measuring systems
PublikacjaThis paper presents the analysis of the new approach to the measurement methodology of significant values (in order of hundreds of kA) and huge steepness (in order of MA/μs) current pulses based on current dividers along with a comparison of the various types transducers suitability in measuring systems with such extreme parameters. Such dividers are used to extend the measurement ranges of current transducers with limited current...
-
Novel fast non-linear electrochemical impedance method for corrosion investigations
PublikacjaThe paper presents a novel approach to corrosion rate monitoring using non-linear electrochemical impedance spectroscopy. The authors propose a new variant of non-linear impedance measurement using amplitude-modulated multi-frequency ac perturbation signal. It allows shortening of measurement duration so it is possible to monitor corrosion rate of the systems experiencing rapid changes. In this way a limitation resulting from lack...
-
Uncertainty Quantification of Additive Manufacturing Post-Fabrication Tuning of Resonator-Based Microwave Sensors
PublikacjaReconfigurability, especially in terms of the ability of adjusting the operating frequency, has become an important prerequisite in the design of modern microwave components and systems. It is also pertinent to microwave sensors developed for a variety of applications such as characterization of material properties of solids or liquids. This paper discusses uncertainty quantification of additive-manufacturing-based post-fabrication...
-
Fractal dimension for bending–torsion fatigue fracture characterisation
PublikacjaFracture surfaces after biaxial fatigue tests were compared using fractal dimension for three types of metallic materials in smooth and notched specimens made of S355J2 and 10HNAP steels and 2017-T4 aluminium alloy, considering both proportional and nonproportional cyclic loading. High-resolution optical 3D measurement studies were performed on the entire fracture surface. A direct correlation between fractal dimension and fatigue...
-
A model of the response of the MGS-6 gravity sensor to tilting
PublikacjaThe reliable interpretation of the measurements made by the Micro-g marine gravimetric system (MGS-6) depends on how the temporary changes of the scale coefficients such as gravimeter scale factor, vertical cross-coupling (VCC) effect, tiltmeter cross and tiltmeter long are compensated for during the signal analysis. The listed coefficients cannot be determined from readings during the measurements or by analysing the final data....
-
The assessment of metrological properties of segmental orifice based on simulations and experiments
PublikacjaSegmental orifices are often used to measure flows of heterogeneous mixtures, especially in flow meters in the power industry, for example. The orifice (with module m= 0.25) was installed in a stainless-steel pipe with internal diameter of 50 mm, placed in a hydraulic water system. The research was performed for Reynolds numbers ranging from 9,000 to 17,000. The flow characteristics of this orifice obtained based on simulation...
-
Analysis of compressive forces in CFGFT cylindrical pillars and their coatings using laboratory tests and metric spaces
PublikacjaThe article discusses compressive forces tests in composite-concrete pillars with the use of laboratory active experiment including the factors and properties of materials which have a significant impact on the test results and their repeatability. A polymer composite based on glass fiber reinforced resin with different fiber beam angles (20, 55 and 85) was used as a buffer/coat of the pole. Due to the problems with direct comparison...
-
Focused ion beam-based microfabrication of boron-doped diamond single-crystal tip cantilevers for electrical and mechanical scanning probe microscopy
PublikacjaIn this paper, the fabrication process and electromechanical properties of novel atomic force microscopy probes utilising single-crystal boron-doped diamond are presented. The developed probes integrate scanning tips made of chemical vapour deposition-grown, freestanding diamond foil. The fabrication procedure was performed using nanomanipulation techniques combined with scanning electron microscopy and focused ion beam technologies....
-
Analysis of exhaled breath for dengue disease detection by low-cost electronic nose system
PublikacjaThis paper presents a procedure and a set-up of an electronic nose system analyzing exhaled breath to detect the patients suffering from dengue – a mosquito-borne tropical disease. Low-power resistive gas sensors (MiCS-6814, TGS8100) were used to detect volatile organic compounds (VOCs) in the exhaled breath. The end-tidal phase of patients exhaled breath was collected with a BioVOCTM breath sampler. Two strategies were assessed...
-
Fast-response optoelectronic detection of explosives’ residues from the nitroaromatic compounds detonation: field studies approach
PublikacjaWe are presenting an application of optoelectronic nitrogen dioxide (NO2) analyzer based on cavity enhanced absorption spectroscopy in the detection of traces of explosives after detonation. It has been shown that the analyzer using blue-violet laser is able to detect explosive residues after the detonation of various amounts of nitroaromatic compounds (75g-1kg) with higher efficiency than the HPLC soil sample testing equipment,...
-
Optical flow method for measuring deformation of soil specimen subjected to torsional shearing
PublikacjaIn this study optical flow method was used for soil small deformation measurement in laboratory tests. The main objective was to observe how the deformation distributes along the whole height of cylindrical soil specimen subjected to torsional shearing (TS test). The experiments were conducted on dry non-cohesive soil specimens under two values of isotropic pressure. Specimens were loaded with low-amplitude cyclic torque to analyze...
-
Methods of trend removal in electrochemical noise data – overview
PublikacjaIn this paper we shall review popular methods of trend removal from electrochemical noise time records. The basic principles of operation of the six most popular methods are explained. The proposed methods are: high - pass filtering, Moving Average Removal, polynomial detrending, wavelet detrending, Empirical Mode Decomposition and Variational Mode Decomposition. Estimation of trend removal quality...
-
Method for determining of shallow water depths based on data recorded by UAV/USV vehicles and processed using the SVR algorithm
PublikacjaBathymetric measurements in waters shallower than 1 m are necessary to monitor seafloor relief changes in the coastal zone. This is especially important for ensuring the safety of navigation, navigation efficiency, as well as during the design and monitoring of hydrotechnical structures. Therefore, the aim of this article is to present a method for determining of shallow water depths based on data recorded by Unmanned Aerial Vehicle...
-
Study on metrological relations between instant tool displacements and surface roughness during precise ball end milling
Publikacja -
Metrological analysis of surface quality aspects in minimum quantity cooling lubrication
Publikacja -
Parametric and nonparametric description of the surface topography in the dry and MQCL cutting conditions
Publikacja -
Optimisation of machining parameters during ball end milling of hardened steel with various surface inclinations
Publikacja -
Influence of geometry and surface morphology of the U-tube on the fluid flow in the range of various velocities
Publikacja -
A diagnosis method of analog parts of mixed-signal systems controlled by microcontrollers.
PublikacjaPrzedstawiono nową klasę K-D metod diagnostyki analogowych części mieszanych sygnałowo mikrosystemów bazujących na mikrokontrolerach. Metody składają się z trzech etapów: etapu przedtestowego tworzenia słownika uszkodzeń, etapu pomiarowego bazujacego na pomiarach próbek napięcia odpowiedzi układu analogowego na pobudzenie impulsem prostokątnym wykonywanych przez wewnętrzne zasoby mikrokontrolera i z etapu detekcji i lokalizacji...
-
Surface topography analysis based on fatigue fractures obtained with bending of the 2017A-T4 alloy
Publikacja -
Fractal dimension for bending–torsion fatigue fracture characterisation
Publikacja -
A fractographic study exploring the fracture surface topography of S355J2 steel after pseudo-random bending-torsion fatigue tests
Publikacja -
A method of fault diagnosis of analog parts of electronic embedded systems with tolerances
PublikacjaPrzedstawiono nową metodę detekcji i lokalizacji uszkodzeń w częściach analogowych z tolerancjami elementów nieuszkodzonych mieszanych sygnałowo elektronicznych systemów wbudowanych sterowanych mikrokontrolerami. Metoda składa się z trzech etapów. W pierwszym etapie tworzony jest słownik uszkodzeń przez aproksymację rodziny pasów lokalizacyjnych. W etapie pomiarowym wewnętrzny licznik mikrokontrolera mierzy czasy trwania impulsów...
-
Cylindrical surface irregularities presented by frequency spectra of relative tool displacement to the workpiece
PublikacjaW pracy przedstawiono częstotliwościowe składowe nierówności powierzchni toczonych. Ponieważ nierówności mają charakter szerokopasmowy, trudny do wartościowania parametrami normatywnymi, zastosowano ich analizę amplitudowo-częstotliwościową, opartą na szybkiej transformacie Fouriera. Zaproponowano oryginalny układ pomiaru sygnału przemieszczeń narzędzia względem przedmiotu dla charakteryzowania nierówności wzdłużnych. Dla generowania...
-
Cylindrical surface irregularities presented by frequency spectra of relative tool displacement to the workpiece
PublikacjaW pracy przedstawiono częstotliwościowe składowe nierówności powierzchni toczonych. Ponieważ nierówności mają charakter szerokopasmowy, trudny do wartościowania parametrami normatywnymi, zastosowano ich analizę amplitudowo-częstotliwościową, opartą na szybkiej transformacie Fouriera. Zaproponowano oryginalny układ pomiaru sygnału przemieszczeń narzędzia względem przedmiotu dla charakteryzowania nierówności wzdłużnych. Dla generowania...
-
Effect of waviness and roughness components on transverse profiles of turned surfaces
PublikacjaThis paper presents the authors method of simultaneous analysis of roughness and waviness irregularity components, with the aim of better defining the key qualities and characteristics.Periodical surface machining traces may be analyzed spectrally, with the irregularity's peaks and troughs being used to define the wave's amplitude.In this work the standard composition for filtering waviness and roughness components of a surface...
-
Simultaneous determination of droxidopa and carbidopa by carbon paste electrode functionalized with NiFe2O4 nanoparticle and 2-(4-ferrocenyl-[1,2,3]triazol-1-yl)-1-(naphthalen-2-yl) ethanone
Publikacja -
Cointegration and how it works for structural health monitoring
Publikacja -
Range-based method of alpha-particle spectrometry using LiF fluorescent nuclear track detectors
Publikacja -
The identification of operational cycles in the monitoring systems of underground vehicles
Publikacja -
Municipal wastewater reclamation: Reclaimed water for hydrogen production by electrolysis – A case study
PublikacjaThis paper presents an analysis of a treatment system selection for municipal wastewater stream based on the DuPont Water Solutions WAVE software. The results obtained based on an analysis of 7 different processing cases studies (ultrafiltration and reverse osmosis) confirmed that the application of 2-pass membrane systems enables the reclamation of water from municipal wastewater that fulfills the requirements concerning the...
-
Measuring moisture damage of asphalt mixtures: The development of a new modified boiling test based on color image processing
Publikacja -
Engineering method of tire rolling resistance evaluation
PublikacjaTire rolling resistance is one of the most difficult tire parameters to measure. The reason is that for modern tires the force of rolling resistance corresponds to 0.5–1% of tire load, thus measurements of very small forces must be performed in a heavily loaded system. This constitutes great problems, especially in road conditions. Laboratory measurements are easier to perform, as the environment may be better controlled, but roadwheel...
-
Homogeneity study of candidate reference material (contaminated soil) based on determination of selected metals, PCBs and PAHs
PublikacjaReference materials (RMs) are an indispensable part of QA/QC system and have played a critical role in the continual expansion of analytical capabilities of the analytical laboratories. The homogeneity study of the candidate for reference material is essential for the quality of reference material (certified reference material) used in quality assurance activities. The homogeneity study of candidate for reference materials of contaminated...