Filtry
wszystkich: 110
Wyniki wyszukiwania dla: biomechanics
-
Friction and flow around growing tissue in bioreactor. Proceedings of the Biomechanics 2003. Engineering Biomechanics - Biomechanics of Sport - Medical Biomechanics.
PublikacjaPrzedstawione zostały problemy teoretyczne związane z wyznaczaniem sił tarcia, współczynników tarcia, rozkładów wartości ciśnienia w warstwie przyściennej wytworzonej wokół hodowanej tkanki w bioreaktorze w trakcie opływu tej tkanki cieczami biologicznymi o właściwościach lepkosprężystych. Model Rivlina Ericksena lepkosprężystej cieczy biologicznej jest tu brany pod uwagę.
-
Acta of Bioengineering and Biomechanics
Czasopisma -
JOURNAL OF BIOMECHANICS
Czasopisma -
Chosen aspects of muscle biomechanics
PublikacjaConsidering a striated skeletal muscle as a different properties mechanical system, one can understand series of important phenomena happening in a real muscle phenomenon of muscle: 1) force delivery to skeletal apparatus through tendons; 2) changing of exerted muscle belly mass distribution with regards to skeletal apparatus; 3) beginning drop of muscle force. A disregard of first phenomenon causes an impossibility to explain...
-
Biomechanics of the medial meniscus in the osteoarthritic knee joint
PublikacjaBackground. Increased mechanical loading and pathological response of joint tissue to the abnormal mechanical stress can cause degradation of cartilage characteristic of knee osteoarthritis (OA). Despite osteoarthritis is risk factor for the development of meniscal lesions the mechanism of degenerative meniscal lesions is still unclear. Therefore, the aim of the study is to investigate the influence of medial compartment knee OA...
-
The Influence of Articular Cartilage Thickness Reduction on Meniscus Biomechanics
PublikacjaObjective Evaluation of the biomechanical interaction between meniscus and cartilage in medial compartment knee osteoarthritis. Methods The finite element method was used to simulate knee joint contact mechanics. Three knee models were created on the basis of knee geometry from the Open Knee project. We reduced the thickness of medial cartilages in the intact knee model by approximately 50% to obtain a medial knee osteoarthritis...
-
Możliwości modelowania w biomechanice = Modelling capabilities in biomechanics
PublikacjaOmówiono mozliwości modelowania w biomechanice. Zaprezentowano główne kierunki badań biomechanicznych oraz metody modelowania, w tym najbardziej popularne oprogramowania do symulacji komputerowej modeli biomechanicznych ciała człowieka. Przedstawiono metody wykorzystania programów komputerowych CHARM, SIMM oraz AnyBody System do utworzenia biomechanicznych modeli ramienia człowieka.
-
CLINICAL BIOMECHANICS
Czasopisma -
Jaw biomechanics: Estimation of activity of muscles acting at the temporomandibular joint
PublikacjaThe aim of this study was to elaborate a method of estimation of activity of surface muscles acting at the temporomandibular joint of the healthy subjects by using a surface electromyography (EMG). The scope of this study involved testing chosen jaw motions (open, close, lateral deviation) and process of mastication occurring during eating food with different toughness (chewing gum, cereal and carrot) by using mixed sides, right...
-
International Biomechanics
Czasopisma -
Series on Biomechanics
Czasopisma -
Biomechanics of Lumbar Spine Injury in Road Barrier Collision–Finite Element Study
PublikacjaLiterature and field data from CIREN database have shown that lumbar spine injuries occur during car crashes. There are multiple hypotheses regarding how they occur; however, there is no biomechanical explanation for these injuries during collisions with road safety barriers (RSBs). Therefore, the objective of this study was to investigate the mechanics of vertebral fractures during car collisions with concrete RSBs. The finite...
-
Biomechanics of the front abdominal wall as a potential factorleading to recurrence with laparoscopic ventral hernia repair
PublikacjaThis study investigated the front abdominal wallto describe its elasticity in vivo and searched for elongationsthat possibly stretched an implanted mesh, therebycausing fixation failure and subsequent recurrence.To measure front abdominal wall elongations, amodel of fascia movements was created. Eight healthyvolunteers were measured during exercise to determine theextent of elongations in their front abdominal wall. Videoswere...
-
Biomaterials and Biomechanics in Bioengineering
Czasopisma -
Molecular & Cellular Biomechanics
Czasopisma -
JOURNAL OF APPLIED BIOMECHANICS
Czasopisma -
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING
Czasopisma -
Journal of Applied Biomaterials & Biomechanics
Czasopisma -
Biomechanics and Modeling in Mechanobiology
Czasopisma -
Applied Bionics and Biomechanics
Czasopisma -
Russian Journal of Biomechanics
Czasopisma -
Yiyong Shengwu Lixue/Journal of Medical Biomechanics
Czasopisma -
Sports Biomechanics
Czasopisma -
Computer Methods in Biomechanics and Biomedical Engineering-Imaging and Visualization
Czasopisma -
3D model of osteoarthritic (OA) knee joint for analysis of the medial meniscus biomechanics - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the OA model thickness of articular cartilage and material parameters of the cartilage and menisci were reduced to simulate degenerative changes in the...
-
3D intact knee model used in analysis of the medial meniscus biomechanics in the osteoarthritic knee joint - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model with original geometry and material parametetrs was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. The file was created in Abaqus 6.14-2, but can be read in a text editor.
-
Journal of Mechanical Engineering and Biomechanics
Czasopisma -
EXPERIMENTS AND SIMULATIONS FOR LAPAROSCOPICVENTRAL HERNIA REPAIR IMPROVEMENT
PublikacjaThe authors conducted a wide experimental and numerical study in order to determine effective approaches in the laparoscopic VH repair. At first the study covered identification of mechanical properties of the abdominal fascia, implants, tacks and transabdominalsutures. Basis on these data, the one and two-dimensional mathematical models were formulated and a number of numerical static and dynamic analyses were carried out. Then...
-
On implementation of fibrous connective tissues’ damage in Abaqus software
PublikacjaConnective fibrous tissues, such as tendons and ligaments, in humans and animals exhibit hyperelastic behaviour. The constitution of the material of these tissues is anisotropic due to the presence of the collagen fibres, where one family of fibres is the typical case. Traumatic events and/or aging may sometimes lead to the damage of the tissue. The study of motion of affected joints or limbs is usually not permitted in vivo. This...
-
Tensile strength of a weave tendon suture using tendons of different sizes
PublikacjaThis study compared the maximum load, stress, elongation at failure and the mode of failure of three kinds of tendons most frequently used for tendon grafting and tendon transfers, using the Pulvertaftweave suture.
-
Physical and mathematical modelling of implant-fascia system in order to improve laparoscopic repair of ventral hernia
PublikacjaThis paper describes an investigation of biomechanical behaviour of hernia repair, which is focused on the selection of safe linking of certain type of implant with fascia in laparoscopic operation. The strength of various fixations of the implant to the fascia is analysed. Methods: The research is based on experimental observations of operated hernia model behaviour during a dynamic impulse load corresponding to post-operative...
-
Influence of meniscus shape in the cross sectional plane on the knee contact mechanics
PublikacjaWe present a three dimensional finite element analysis of stress distribution and menisci deformation in the human knee joint. The study is based on the Open Knee model with the geometry of the lateral meniscus which shows some degenerative disorders. The nonlinear analysis of the knee joint under compressive axial load is performed. We present results for intact knee, knee with partial and complete radial posterior meniscus root...
-
Investigation of abdomen surface deformation due to life excitation: implications for implant selection and orientation in laparoscopic ventral hernia repair
PublikacjaVentral hernia is a common medical problem. Statistically there are around 10% recurrences of the sickness. The authors' former investigation proved edges of the hernia orifice displacements to be one of the factors causing recurrence. Thus, experimental investigation of the abdomen surface deformation due to some normal activities of people is studied.The extreme strains, their localization and directions are identified. The acquired...
-
Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublikacjaAbstrakt artykułu pt. ''Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity''. The paper describes techniques to improve the bioactivity of titanium and ehnahnce the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotubular oxide layer.
-
Preparation of the porous biomaterial based on titanium alloy for orthopaedic implants
PublikacjaObecnie tytan i jego stopy (Ti-6Al-4V lub Ti-13Nb-13Zr) są szeroko stosowane jako biomateriały dla implantów ortopedycznych. Stale prowadzone są badania nad ich najlepszą odpornością na korozję i zużycie ścierne oraz biozgodnością i bioaktywnością. Obecne badania również skoncentrowane są na projektowaniu, wytwarzaniu i właściwościach materiałów porowatych na podstawie na przykład stopu tytanu (Ti-13Nb-13Zr), które mogą być stosowane...
-
Biocompatibility and bioactivity of bearing loaded metallic implants
PublikacjaPresentation of developed titanium alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behavior for bearing loaded implants, e.g. hip joint and knee joint endoproshtesis.
-
Muscle strength and endurance in high-level rock climbers
Publikacja -
A Multi Rig Screening Test for Thin Ceramic Coatings in Bio-Tribological Applications
PublikacjaZaprezentowano metodę badań ogólnej charakterystyki tribologicznej cienkich powłok ceramicznych z wykorzystaniem równoległych testów na wielu stanowiskach o różnej konfiguracji styku powierzchni trących i przy ruchu o różnym charakterze (jednokierunkowym i posuwisto zwrotnym). Przedstawiono wyniki porównania przy pomocy jednoczesnej analizy wyników testów z różnych stanowisk; w wyniku testów uzyskano ranking powłok ze wskazaniem...
-
Degradation of metallic implants
PublikacjaPresence of metallic implants made of stainless steels, Co and Ti alloys is sometimes followed by some undesired allergic reactions and inflammatory processes and consequently the necessity of reimplantation.
-
Influence of laser melting on surface layer properties of titanium alloy Ti6Al4V
PublikacjaIn time of rapid technology and medicine progress, implants are becoming more widely used in the human body, ranging from dental implants, stabilizing plates, screws, orthopaedic prostheses. For example, there are many types of hip prostheses used for hip replacement as well as various types of materials used for these orthopaedic prostheses. Properties of titanium alloys used in hip prostheses combined with good strength properties,...
-
In vivo performance of intraperitoneal onlay mesh after ventral hernia repair
PublikacjaBackground: Ventral hernia repair needs to be improved since recurrence, postoperative pain and other complications are still reported in many patients. The behavior of implants in vivo is not sufficiently understood to design a surgical mesh mechanically compatible with the human abdominal wall. Methods: This analysis was based on radiological pictures of patients who underwent laparoscopic ventral hernia repair. The pictures...
-
The early failure of the gamma nail and the dynamic hip screw in femurs with a wide medullary canal. A biomechanical study of intertrochanteric fractures
PublikacjaBackground: Intertrochanteric fractures may occur in a bone with a wide medullary canal that may lead to significant mobility of a intramedullary nail, contrary to an extramedullary device. This study evaluates the Dynamic Hip Screw and the gamma nail in AO 31.A2.1 fractures in these circumstances. Methods: Synthetic femora with canals drilled to 18 mm were used. Five fixation types were examined: a 2 - hole and a 4 – hole Dynamic...
-
Mechanical behaviour of knit synthetic mesh used in hernia surgery
PublikacjaPurpose: There is a discussion in literature concerning mechanical properties and modelling of surgical meshes. An important feature of elastic modulus dependency on load history is taken into account in this paper, as implants are subjected to variable loading during human activity. The example of DynaMesh®-IPOM surgical implant is studied. Methods: The analysis is based on failure tension tests and cyclic loading and unloading...
-
The effective elastic properties of human trabecular bone may be approximated using micro-finite element analyses of embedded volume elements.
PublikacjaBoundary conditions (BCs) and sample size affect the measured elastic properties of cancellous bone. Samples too small to be representative appear stiffer under kinematic uniform BCs (KUBCs) than under periodicity-compatible mixed uniform BCs (PMUBCs). To avoid those effects, we propose to determine the effective properties of trabecular bone using an embedded configuration. Cubic samples of various sizes (2.63, 5.29, 7.96, 10.58...
-
Mechanical behaviour of the implant used in human hernia repair under physiological loads
PublikacjaIn laparoscopic operations of abdominal hernias some recurrences still take place, even when applying a surgical mesh. This is usually caused by a failure of the connection between the tissue and the implant. The study deals with the influence of an implant’s orientation on forces in joints, which connect the mesh to human tissues. In the paper, the implant is modelled as a membrane structure within framework of the Finite Element...
-
Method for assessing the dynamics and efficiency of diving fins
Publikacja -
Influence of geometry and annealing temperature in argon atmosphere of TiO2 nanotubes on their electrochemical properties
Publikacja -
Analysis of muscles behaviour : The computational model of muscle. -Part I
PublikacjaW artykule zaproponowano model obliczeniowy mięśnia szkieletowego, który potraktowano jako strukturę o złożonych i zróżnicowanych właściwościach mechanicznych. Szczegółowo opisano metodę identyfikacji tych właściwości. Ponadto określono sposób przeprowadzenia weryfikacji ilościowej i jakościowej zaproponowanego modelu. Za pomocą takiego obliczeniowego modelu mięśnia można łatwo określać siły w mięśniach, które należą do zespołu...
-
Estimation of hydromechanical parameters of limb lymphedematous tissue with the use of chamber tests
Publikacja -
Comparison of two polymers PDO and PLLA/PCL in application of urological stent for the treatment of male urethral stenosis.
Publikacja