Filtry
wszystkich: 35013
wybranych: 1452
-
Katalog
- Publikacje 23198 wyników po odfiltrowaniu
- Czasopisma 82 wyników po odfiltrowaniu
- Konferencje 3 wyników po odfiltrowaniu
- Wydawnictwa 6 wyników po odfiltrowaniu
- Osoby 745 wyników po odfiltrowaniu
- Wynalazki 102 wyników po odfiltrowaniu
- Projekty 301 wyników po odfiltrowaniu
- Laboratoria 18 wyników po odfiltrowaniu
- Zespoły Badawcze 43 wyników po odfiltrowaniu
- Aparatura Badawcza 8 wyników po odfiltrowaniu
- Kursy Online 7133 wyników po odfiltrowaniu
- Wydarzenia 603 wyników po odfiltrowaniu
- Dane Badawcze 2771 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: RNA-SEQ
-
ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Man 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Man 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Man 53 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 24 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Man 53 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 24 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 24 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
Short-term measurement of physiological parameters - teenager (5 min) - 3.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (10 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (10 minutes) measurements of physiological parameters were performed on the healthy...
-
Determining the optimal filling of the surface with a linker with Universal Force Field and Reax Force Field
Dane BadawczeThe DataSet contains the atomic slabs of diamond surfaces with ATP molecules in water. The calculated data includes different sized surfaces from 90 Angstrom^2 to 691 Angstrom^2. Structures were relaxed using the Reax Force Field method with the Limited Memory Broyden–Fletcher–Goldfarb–Shanno algorithm. Structures were calculated with a convergence...
-
Short-term measurement of physiological parameters - teenager (5 min) 7.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (20 min) 2.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (15 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (15 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (10 min)_3.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (10 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (30 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (25 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) 6.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (40 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (40 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 2.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 5.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (20 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 6.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (25 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (25 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 4.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
The time-varying low-frequency magnetic-field emitted from the ship’s inverter-fed induction motor
Dane BadawczeThe dataset contains the magnetic field measurement results that are part of a comprehensive study on the assessment of the magnetic field emissions onboard of the research-training vessel. The measurements were carried out, nearby the bow thruster motor fed from the inverter, during maneuvering and the sea voyage. The bow thruster is assembled in the...
-
Tagged images with bees
Dane BadawczeImages taken from bee hive with tagged bees. The images are prepared for training yolo5 deep neural network (supplied with the data).
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 49 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 49 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 29 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
Barrett-Joyner-Halenda (BJH) and Brunauer-Emmett-Teller (BET) analysis of wood and straw based biochars
Dane BadawczeThis data set includes the BJH and BET analysis results for straw and wood chips-based biochars generated at 450 Celsius degrees.
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 27 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
The microstructure of AA5754 alloy under corrosion in alkaline media (pH=11) with 20 mM of various carboxylic acids
Dane BadawczeThis dataset contains scanning electron microscopy (SEM) micrographs taken for polished aluminum AA5754 alloy samples, exposed for 100 min in bicarbonate buffer (pH=11) with the addition of 20 mM of carboxylic acids, namely: citric acid, malic acid, maleic acid, succinic acid, tartaric acid, tricarballylic acid and serine. The goal of this study was...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 29 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
The microstructure of AA5754 alloy under corrosion in alkaline media (pH=11) with 4.5 mM of various carboxylic acids
Dane BadawczeThis dataset contains scanning electron microscopy (SEM) micrographs taken for polished aluminum AA5754 alloy samples, exposed for 100 min in bicarbonate buffer (pH=11) with the addition of 4.5 mM of carboxylic acids, namely: citric acid, malic acid, maleic acid, succinic acid, tartaric acid, tricarballylic acid and serine. The goal of this study was...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
Depth profile of the chemical composition of the Au-Ag multilayers
Dane BadawczeSilver and gold multilayers were deposited on a silicon substrate by magnetron sputtering method. Both type, Au and Ag thin films had 2 nm of thickness. Totally structure had thickness of 6 nm (Au-Ag-Au). That prepared multilayers were measured by XPS method. To obtain a depth profile of chemical composition, an Argon ion (Ar+) gun was used for etching...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 24 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 53 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
The effect of cobalt addition on the corrosion behavior of near equiatomic NiTi shape memory alloy in normal saline solution, impedance and microscopic studies
Dane BadawczeThe electrochemical and corrosion (uniform and localized) behavior of a binary Ni52Ti48 shape memory alloy (SMA) and two ternary Ni52Ti48-xCox (x = 1.5 and 4.0 wt.%) SMAs were studied. Measurements were conducted in 0.9% NaCl solution at 37 oC. This dataset contains the results of electrochemical impedance spectroscopy (EIS) studies done on daily basis...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 53 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...