Filtry
wszystkich: 143
wybranych: 96
-
Katalog
Filtry wybranego katalogu
Wyniki wyszukiwania dla: INTERFEROMETER
-
Detection of immunological agent by optical fiber sensor: preliminary study
PublikacjaThe objective of this study is the application of optical methods for detection of immunological agent concentration. As the agent we used the Cyclaid, produced by Apotex Inc. In this article we investigated different Cyclaid concentrations in water. We used a Fabry-Pérot interferometer working in a reflective mode, the measurements were performed with source with central wavelength λ = 1550 nm. The preliminary investigation have...
-
Fiber-optic Fabry-Pérot sensors – modeling versus measurements results
PublikacjaThis paper describes how parameters of investigated substances and the fiber-optic Fabry-Pérot sensing interferometer affect the spectrum of the optical radiation at the output of the sensor. First, the modeling of the operation of the sensing interferometer was conducted. Most important parameters and effects that were taken into account are: dependences of the refractive indices of the core and the cladding, as well the mode...
-
High-Resolution, Broad-Range Detection Setup for Polarimetric Optical Fiber Sensors
PublikacjaA common-path polarization interferometer using a Wollaston prism and an area detector for the measurement of retardation or optical path difference is presented. Employing a moderate-resolution 1280 by 1024 pixel monochrome camera, it offers a measurement range of approximately 780 radians at 830 nm and 1350 radians at 515 nm while maintaining a high measurement resolution. Retardation introduced by a zero-order waveplate or a...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublikacjaFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublikacjaFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Low-coherence Fiber-Optic Interferometric Sensors
PublikacjaW artykule porównano parametry metrologiczne zrealizowanych niskokoherencyjnych czujników światłowodowych wykorzystujących interferometr Michelsona oraz Fabry-Perot.
-
Nitrogen-Doped Diamond Film for Optical Investigation of Hemoglobin Concentration
PublikacjaIn this work we present the fabrication and characterization of a diamond film which can be utilized in the construction of optical sensors for the investigation of biological samples. We produced a nitrogen-doped diamond (NDD) film using a microwave plasma enhanced chemical vapor deposition (MWPECVD) system. The NDD film was investigated with the use of scanning electron microscopy (SEM), atomic force microscopy (AFM) and Raman...
-
Fiber optic displacement sensor with signal analysis in spectral domain
PublikacjaIn this paper, a study of a low-coherence fiber optic displacement sensor is presented. The sensor consisted of a broadband source whose central wavelength was either at 1310 nm or 1550 nm, a sensing Fabry-Pérot interferometer operating in reflective mode and an optical spectrum analyzer acting as the detection setup. All these components were connected by a single-mode fiber coupler. Metrological parameters of the sensor were...
-
Optimization of white light interferometric temperature sensor. Workshop on Atomic and Molecular Physics.
PublikacjaW artykule przedstawiono metodę optymalizacji parametrów niskokoherencyjnego interferometrycznego czujnika temperatury wykorzystującego miniaturowy interferometr Farby Perota, pracujący w modzie odbiciowym.
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublikacjaThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
FIBRE-OPTIC SENSOR FOR SIMULTANEOUS MEASUREMENT OF THICKNESSAND REFRACTIVE INDEX OF LIQUID LAYERS
PublikacjaIn this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers. We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry–Pérot interferometer acting as the sensing head. We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We...
-
Low-coherence method of hematocrit measurement
PublikacjaDuring the last thirty years low-coherence measurement methods have gained popularity because of their unique advantages. Low-coherence interferometry, low-coherence reflectometry and low-coherence optical tomography offer resolution and dynamic range of measurement at the range of classical optical techniques. Moreover, they enable measurements of the absolute value of the optical path differences, which is still an unsolved problem...
-
In-situ optical diagnostics of boron-doped diamond films growth
PublikacjaInterferometry is a desirable method for in-situ measurement of thin, dielectric film growth, as it don't modify conditions of film deposition. Here we present interferometrical measurements of thickness of doped diamond films during Chemical Vapor Deposition (CVD) process. For this purpose we used a semiconductor laser with a 405nm wavelength. Additional ex-situ measurement using spectral interferometry and ellipsometry...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublikacjaIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
Effect of temperature change on refractive index of an egg white and yolk: a preliminary study
PublikacjaIn this article, the refractive index of an egg white and yolk depending on temperature in range 30 - 47 °C over 1550 nm was determined. The measurement head was constructed as fiber optic Fabry-Perot interferometer with interference between polished fiber end-face and aluminum weighing dish. The measurement setup has been made of an optical spectrum analyzer, a superluminescent diode with a central wevelength of 1550 nm, 2:1 fiber...
-
1D portable optical coherence tomography system
Publikacja—Imaging methods are an expanding branch of technology, which involves data acquisition and analysis of images for research and diagnostics. This paper has been devoted to the description of the optical design for a one-dimensional, portable optical coherence tomography (OCT) system. The Mach-Zehnder interferometer has been designed in the presented study. The description of the construction and applied hardware solutions have...
-
The silver layers in fiber-optic sensors
PublikacjaIn this paper a method of application of the silver layers on the surface of an optical fiber was proposed. The optical properties and surface quality of the silver layer was examined by optical microscopy. The reflection and transmission of the sample were investigated. To evaluate the silver mirror it was placed in a fiber optic Fabry-Perot interferometer and the quality of the spectra was analyzed. The commercial mirror was...
-
Badanie niejednorodności warstwy ceramiki PLZT metodami optycznej interferometrii niskokoherentnej
PublikacjaW artykule omówiono metodę badania wewnętrznej struktury materiałów ceramicznych z wykorzystaniem interferometrii niskokoherentnej. Przedstawiono układ pomiarowy optycznej tomografii koherentnej, wykorzystujący niskokoherentny interferometr do badania niejednorodności występujących w strukturze ośrodków rozpraszających. Zaprezentowano wyniki pomiarów grubości i niejednorodności ceramicznych warstw PLZT. Przeprowadzono rozważania...
-
Badanie niejednorodności warstwy ceramiki PLZT metodami optycznej interferometrii niskokoherentnej
PublikacjaW artykule omówiono metodę badania wewnętrznej struktury materiałów ceramicznych z wykorzystaniem interferometrii niskokoherentnej. Przedstawiono układ pomiarowy optycznej tomografii koherentnej, wykorzystujący niskokoherentny interferometr do badania niejednorodności występujących w strukturze ośrodków rozpraszających. Zaprezentowano wyniki pomiarów grubości i niejednorodności ceramicznych warstw PLZT. Przeprowadzono rozważania...
-
Eine Eeue Technik zur Präzisen Rissfortschrittsmessung im DCB oder im Keilversuch = A novel technique for precise crack length measurement in the DCB or wedge test
PublikacjaDiverse methods have been tried to study crack length, most basic relying on direct, or microscopic, observation of the crack tip position. Optical correlation, both lasermoiré and speckle interferometry, a single strain gauge and displacement sensorshave also been employed. Crack length measurement is, however, delicate. We present a novel method making use of strain gauges attached to one of the adherends.
-
Modeling of multi-cavity Fabry-Perot optical fiber sensors
PublikacjaReflectance characteristics of a two-cavity extrinsic Fabry-Perot optical fiber sensor were investigated using computer modeling. Calculations were performed using a plane wave-based approach, selected for clarity of results. Based on the modeling results, it can be concluded that the two-cavity Fabry-Perot interferometer can be used to measure two different quantities, such as refractive index and temperature, independently. It...
-
Compressible gas density measurement by means of Fourier analysis of interferograms
PublikacjaThis paper describes a method for nonintrusive compressible gas density measurement by means of automated analysis of interferograms using FFT (Fast Fourier Transform), and its implementation using DFT (Discrete Fourier Transform), that does make this measurement technique a fairly valuable and accessible experimental method. The presented approach makes it possible to use the finite fringe setting of the interferometer, thus reducing...
-
Quantum mechanical which-way experiment with an internal degree of freedom
PublikacjaFor a particle travelling through an interferometer, the trade-off between the available which-way information and the interference visibility provides a lucid manifestation of the quantum mechanical wave-particle duality. Here we analyse this relation for a particle possessing an internal degree of freedom such as spin. We quantify the trade-off with a general inequality that paints an unexpectedly intricate picture of wave-particle...
-
Doped Nanocrystalline Diamond Films as Reflective Layers for Fiber-Optic Sensors of Refractive Index of Liquids
PublikacjaThis paper reports the application of doped nanocrystalline diamond (NCD) films—nitrogen-doped NCD and boron-doped NCD—as reflective surfaces in an interferometric sensor of refractive index dedicated to the measurements of liquids. The sensor is constructed as a Fabry–Pérot interferometer, working in the reflective mode. The diamond films were deposited on silicon substrates by a microwave plasma enhanced chemical vapor deposition...
-
White-light interferometric temperature sensor for biomedical diagnostic.
PublikacjaW artykule opisano opracowany model miniaturowego, światłowodowego czujnika temperatury z interferometrem Fabry-Perot wykorzystującego interferencję światła białego przeznaczonego do zastosowań biomedycznych. Analizowano czujnik wykonany ze światłowodu wielomodowego o skokowym profilu współczynnika załamania oraz ze światłowodu monomodowego. Zasadniczym celem był dobór parametrów mający na celu uzyskania maksymalnej widzialności...
-
The role of low-energy electrons in the charging process of LISA test masses
PublikacjaThe estimate of the total electron yield is fundamental for our understanding of the test-mass charging associated with cosmic rays in the Laser Interferometer Space Antenna (LISA) Pathfinder mission and in the forthcoming gravitational wave observatory LISA. To unveil the role of low energy electrons in this process owing to galactic and solar energetic particle events, in this work we study the interaction of keV and sub-keV...
-
Implementation of SiN thin film in fiber-optic sensor working in telecommunication range of wavelengths
PublikacjaMirrors are used in optical sensors and measurement setups. This creates a demand for mirrors made of new materials and having various properties tailored to specific applications. In this work, we propose silicon covered with a thin silicon nitride layer as a mirror for near-infrared measurements. SiN layer was deposited on a standard silicon wafer with a Low-Pressure Chemical Vapor Deposition furnace. Then, the created layer...
-
Interferometric optical fiber sensors with active stabilization of the operating point using a tunable semiconductor laser. Optical Fibres and Their Applications VIII.
PublikacjaW pracy przedstawiono wyniki badań światłowodowych interferometrycznych sensorów siły wykonanych w konfiguracji interferometru Michelsona i wykorzystujących aktywną stabilizację punktu pracy przy pomocy zmiany długości fali źródła. Porównano dwie klasy omawianych sensorów a następnie zrealizowano sensor. W konstrukcji sensora zastosowano modulator z pośrednim pomiarem siły. Mierzona siła jest zamieniana na ciśnienie hydrostatyczne,...
-
Incorporation of nitrogen in diamond films – A new way of tuning parameters for optical passive elements
PublikacjaThis paper investigates the impact of nitrogen incorporation in diamond films for the construction of an interferometric sensor to measure displacement. Diamond films with different nitrogen levels (0–5%) were deposited on silicon substrates by microwave plasma enhanced chemical vapor deposition. The structural characteristics of these samples are characterized using scanning electron microscopy (SEM), atomic force microscopy (AFM), confocal...
-
Low-volume label-free SARS-CoV-2 detection with the microcavity-based optical fiber sensor
PublikacjaAccurate and fast detection of viruses is crucial for controlling outbreaks of many diseases; therefore, to date, numerous sensing systems for their detection have been studied. On top of the performance of these sensing systems, the availability of biorecognition elements specific to especially the new etiological agents is an additional fundamental challenge. Therefore, besides high sensitivity and selectivity, such advantages...
-
Displacement Sensors Based on the Phase of the Reflection Coefficient of a Split Ring Resonator Loaded Transmission Line
Publikacja— In this paper, novel displacement sensors using a microstrip loaded with a pair of split ring resonators (SRRs) are proposed. It is shown that the phase of the reflection coefficient from the loading SRRs can be used for displacement sensing. The paper also proposes a differential version of the sensor that benefits from a higher sensitivity and reference zero, which is useful for alignment purposes. It is further shown that...
-
Incorporation of nitrogen in diamond films - A new way of tuning parameters for optical passive elements
PublikacjaThis paper investigates the impact of nitrogen incorporation in diamond films for the construction of an interferometric sensor to measure displacement. Diamond films with different nitrogen levels (0–5%) were deposited on silicon substrates by microwave plasma enhanced chemical vapor deposition. The structural characteristics of these samples are characterized using scanning electron microscopy (SEM), atomic force microscopy...
-
Nanocrystalline diamond sheets as protective coatings for fiber-optic measurement head
PublikacjaFiber-optic sensors find numerous applications in science and industry, but their full potential is limited because of the risk of damaging the measurement head, in particular, due to the vulnerability of unprotected tips of the fiber to mechanical damage and aggressive chemical agents. In this paper, we report the first use of a new nanocrystalline diamond structure in a fiber-optic measurement head as a protective coating of...
-
Computer support of analysis optical spectra measurements
PublikacjaVerification of measurement errors has a big impact on assessment of accuracy of conducted measurements and obtained results. In many cases computer simulation results are compared with measurement results in order to evaluate measurement errors. The purpose of our research was to check the accuracy of measurements made with Fabry-Perot interferometer working in the transmission mode. In measurement setup, a 1310 nm superluminescent...
-
Computer Support of Analysis of Optical Spectra Measurements
PublikacjaThe verification of measurement errors has a big impact on the assessment of the accuracy of conducted measurements and obtained results. In many cases, computer simulation results are compared with measurement results in order to evaluate measurement errors. The purpose of our research was to check the accuracy of measurements made with a Fabry–Perot interferometer working in the transmission mode. In the measurement setup, a...
-
Investigation of the Few‐Layer Black Phosphorus Degradation by the Photonic Measurements
PublikacjaFew-layer black phosphorus (FLBP) is a 2D material that gains worldwide interest for its possible applications, mainly in electronics and optoelec-tronics. However, as FLBP is prone to a degradation process under envi-ronmental conditions, there is a need for a monitoring method allowing investigation of its surface quality. Among many techniques, optoelectronic ones have unique advantages of fast response, non-contact, and non-invasive...
-
Design and Experiments of a Piezoelectric Motor Using Three Rotating Mode Actuators
PublikacjaThis paper represents a numerical and experimental investigation of the multicell piezoelectric motor. The proposed design consists of three individual cells that are integrated into the stator, double rotor, and a preload system combined into a symmetrical structure of the motor. Each of the cells is characterized by a traveling wave and rotating mode motor. A finite element numerical analysis is carried out to obtain optimal...
-
Optical fiber aptasensor for label-free bacteria detection in small volumes
PublikacjaHighly sensitive devices for fast bacteria detection are sought to be developed with the task of quantifying the worldwide problem of pathogenic bacteria and thus helping to take control over spreading bacterial infections. This work concerns a sensing solution based on microcavity in-line Mach-Zehnder interferometer (μIMZI) induced in an optical fiber. Such a device exhibits ultrahigh sensitivity to refractive index changes...
-
Plasma-Based Deposition and Processing Techniques for Optical Fiber Sensing
PublikacjaPlasma-based techniques are widely applied for well-controlled deposition, etching or surface functionalization of a number of materials. It is difficult to imagine fabrication of novel microelectronic and optoelectronic devices without using plasma-enhanced deposition of thin films, their selective etching or functionalization of their surfaces for subsequent selective binding of chemical or biological molecules. Depending on...
-
Zirconia ceramics with additions of Alumina for advanced tribological and biomedical applications
PublikacjaThe results of an investigation on slip cast and sintered Y2O3 (3 wt%)- stabilized ZrO2 with additions of 5, 10, 15 wt% Al2O3 are reported. The surface roughness, porosity and density of the samples were measured. The hardness HRc and Hv, fracture toughness K1C, and friction coefficients were also measured using standard methods. The structural properties of the samples were observed by Scanning Electron Microscopy (SEM). The surface...
-
Optical profilometer
PublikacjaThe profilometry plays a huge role in the most fields of science and technology. It allows to measure the profile of the surface with high-resolution. This technique is used in the fields like optic, electronic, medicine, automotive, and much more. The aim of the current work was to design and build optical profilometer based on the interference phenomena. The developed device has been working with He-Ne laser (632.8 nm). The optical...
-
TIME SERIES DATA FOR 3D FLOOD MAPPING
PublikacjaThanks to the ability to collect information about large areas and with high frequency in time areas threatened by floods can be closely monitored. The effects of flooding are socio-economic losses. In order to reduce those losses, actions related to the determination of building zones are taken. Moreover, the conditions to be met by facilities approved for implementation in such areas are determined. Therefore, satellite data...
-
Real-time isothermal DNA amplification monitoring in picoliter volumes using an optical fiber sensor
PublikacjaRolling circle amplification (RCA) of DNA can be considered as a great alternative to the gold standard polymerase chain reaction (PCR), especially during this pandemic period, where rapid, sensitive, and reliable test results for hundreds of thousands of samples are required daily. This work presents the first research to date on direct, real-time and label-free isothermal DNA amplification monitoring using a microcavity in-line...
-
Modyfikowane nanodiamentowe warstwy do sensorów z detekcją optyczną i elektrochemiczną
PublikacjaW rozprawie doktorskiej przedstawiono opracowanie parametrów procesów syntezy osadzania z fazy gazowej wspomaganego plazmą mikrofalową (MWPACVD) do wytwarzania warstw nanodiamentowych o niskim współczynniku absorpcji optycznej i wysokiej przewodności elektrycznej. Warstwy te są przeznaczone do sensorów z detekcją optyczną i elektrochemiczną stosowanych w układzie interferometru Mach-Zehndera do badania in situ modyfikacji elektrod...
-
Niskokoherencyjne czujniki światłowodowe przeznaczone do pracy w warunkach zmieniającego się tłumienia sygnału w torze optycznym
PublikacjaRozprawa poświęcona jest zagadnieniu niskokoherencyjnych czujników światłowodowych. Badania przedstawione w pracy miały na celu ocenę możliwości zaimplementowania niskokoherencyjnych czujników światłowodowych do pomiaru różnych wielkości fizycznych z uwzględnieniem warunków zmieniającego się tłumienia sygnału w torze optycznym. W rozprawie zawarto informacje na temat czujników światłowodowych. Dokonano również analizy stanu wiedzy...
-
Sensors for Rapid Detection of Environmental Toxicity in Blood of Poisoned People
PublikacjaRecently, the diagnosis and treatment of poisoned person can be done only in specialized centers. Furthermore, currently used clinical methods of intoxication diagnosis are not sufficient for early detection. Conventional laboratory tests based on urine and blood require professional, high skilled staff, high cost equipment as well as they are arduous and lasting analytical procedures. There is a need to elaborate relatively cheap...