Filtry
wszystkich: 1260
wybranych: 903
Wyniki wyszukiwania dla: VOLTAGE UNBALANCING
-
Control of a wind power generator in case of voltage sags in power network
PublikacjaW artykule poruszono problem związany ze sposobem sterowania generatorem elektrowni wiatrowej w przypadku wystąpienia po stronie sieci zapadów napięcia.Jako generator wykorzystano maszynę dwustronnie zasilaną której stojan podłączono bezpośrednio do sieci natomiast wirnik zasilano poprzez kaskadę przekształtników. Wystąpienie spadku lub zapadu napięcia sieci w przypadku pracy tego typu generatora może doprowadzić do uszkodzenia...
-
A Review of Reduction Methods of Impact of Common-Mode Voltage on Electric Drives.
PublikacjaIn this survey paper, typical solutions that focus on the reduction in negative effects resulting from the common-mode voltage influence in AC motor drive applications are re-examined. The critical effectiveness evaluation of the considered methods is based on experimental results of tests performed in a laboratory setup with an induction machine fed by an inverter. The capacity of a common-mode voltage level reduction and voltage...
-
The effect of cable duct diameter on the ampacity of high-voltage power cables
PublikacjaThe ampacity of power cables depends, among others, on the conditions of heat dissipation from the cable to the environment. Cables are usually laid directly in the ground, but in some sections, they may be placed in ducts, which adversely affects the ampacity of the cable line. The paper presents heat transfer phenomena for cables installed in pipe-type ducts filled with air. The effect of cable duct diameter on this ampacity...
-
Voltage Harmonic Distortion Measurement Issue in Smart-Grid Distribution System
PublikacjaThis paper presents the investigation results ofvoltage harmonic transfer accuracy problems through voltagetransformers which are widely used in power quality monitoringsystems in medium and high voltage grids. A simplified lumpedparameters circuit model of the voltage transformer is presentedand verified by simulation and experimental investigations. Anumber voltage transformers typically used in medium voltagegrid has been tested...
-
Sensorless induction motor drive with voltage inverter and sine-wave filter
PublikacjaThis paper presents a speed sensorless control system of an induction motor with an output LC filter. It is known that the parameters design of the filter gives sine wave motor supply voltage but complicates control and estimation process. The reason is that the voltage drop and phase shift between filter input and output signals are imposed, and hence the motor voltages and currents differ from the inverter output waveforms. To...
-
The photocurrent quantum efficiency dependence on the applied voltage in organic solar cells
PublikacjaWe demonstrate that our recently reported model (Szmytkowski 2007 J. Phys. D: Appl. Phys. 40 3352) of the photocurrent quantum efficiency in organic semiconductors explains the external quantum efficiency dependence on the electric field in organic solar cells. This effect can be explained by taking into account that the photogeneration of charge carriers occurs via the electron-hole pair dissociation and the space charge effects...
-
Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
PublikacjaThe paper dealt with the issue of breakdowns detection of isolated hanging wires on the medium-voltage transmission. The main aim of article is to describe the function of created breakdowns detector and evaluation its. The breakdowns detector is created based in indicators of faults such as touch between tree limbs and insulated wire, touch tree limbs with several phases or fall insulated wire on the ground. Breakdowns detector...
-
Synchronized six-step voltage generation in high-speed PMSM drive
PublikacjaSynchronized voltage generation has already been considered in the context of pulse width modulation (PWM). References prove that synchronized PWM substantially decreases subharmonics in inverter output voltage when operating with low switching-to-fundamental frequency ratio. This paper identifies problems of unsynchronized voltage generation in electric drives under six-step inverter operation. Guidelines for the synchronization...
-
Energy losses reduction in the medium voltage cable line – case study
PublikacjaThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
Selection of energy storage units by genetic algorithm for mitigating voltage deviations
PublikacjaIn recent years, energy storage units have become very popular. They are applied both for economic and technical purposes. Unfortunately, the cost of such devices is still high and selecting their proper location and rated power have to be performed precisely. In this paper, a Genetic-Algorithm-based optimization method for selecting the best configuration of energy storage units in the power network is proposed. The presented...
-
Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives
PublikacjaThis paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...
-
Selected Technical Requirements for Photovoltaic Plant Interconnection with a Medium Voltage Grid
PublikacjaThe article discusses some selected technical requirements, which according to these authors should be recognised and met by photovoltaic power plants connected to national distribution grids in the context of their likely development. This development today is limited, since Polish legislation has not implemented the relevant EU Directive [8]. The study points out the purposefulness of incorporating the necessary requirements...
-
A versatile analog CMOS cell: voltage - buffer /current - conveyor/ multiplier
PublikacjaW pracy przedstawiono koncepcję uniwersalnej komórki analogowej przeznaczonej dla programowalnych układów analogowych (FPAA). Komórka może pełnić funkcję bufora napięciowego, konwjora prądowego lub mnożnika analogowego. Układ przesymulowano w technologii CMOS 2 ćm.
-
Critical evaluation of resonaut gc voltage link inventures for electrical drives.
PublikacjaPrzedstawiono wyniki modelowania i symulacji falowników z centralnym obwodem rezonansowym dla zastosowań w napędzie elektrycznym. Porównano struktury ukladów z rezonansowym równoległym obwodem pośredniczącym o ograniczonej wartości szczytowej i uasi-rezonansowych. Dla potrzeb projektowania tych układów, wobec przeciwstawnych funkcji celu dokonano ich wielokrytycznej oceny.
-
Design of synchronous generator voltage regulator based on h control theory
PublikacjaThe power system is highly nonlinear system, which dynamics depends on system network configuration, system loading…etc. To overcome the above mentioned difficulties and to fulfill the performance requirements the different control methods are considered and tested for application to generating control unit. Application of the H optimization method to automatic voltage regulator is studied in this paper. Simulation results have...
-
Performance of Passive and Active Balancing Systems of Lithium Batteries in Onerous Mine Environment
PublikacjaTo use lithium-iron-phosphate battery packs in the supply systems of any electric mining equipment and/or machines, the required conditions of work safety must be met. This applies in particular to coal mines endangered by fire and/or explosion. To meet the spark-safety conditions, the cells (together with the battery management system—BMS) must be isolated from the influence of the environment, and therefore placed in special...
-
Optimization of The Shortest-Path Routing with Equal-Cost Multi-Path Load Balancing
Publikacja -
Implementation of failover and load balancing algorithms in SIP PBX High Availability system
PublikacjaGoal of the project was to design a High Availability SIP VoIP system that guarantees access to additional services like auto-attendent and automatic call distribution. The realization of the project required system to have load balancing and failover algorithms implemented. From the end users’ point of view the whole system had to figure as a single element. After taking under consideration the known methods of implementations...
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublikacjaThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublikacjaThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.
-
The Application of Kernel Density Estimation for Aided the Process of Locating Sources of Voltage Fluctuations
Publikacja -
Trace of Flicker Sources by Using Non-Parametric Statistical Analysis of Voltage Changes
Publikacja -
AM Modulation Signal Estimation Allowing Further Research on Sources of Voltage Fluctuations
Publikacja -
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
State feedback control of the PMSM servo-drive with sinusoidal voltage source inverter
Publikacja -
Structural Investigations and Determination of Current and Voltage Characteristics in Htsc 2G SF12050 Tapes
Publikacja -
Computer simulation of current voltage response of elektrocatalytic sensor.Optoelectronic and Electronic Sensors V.
PublikacjaW pracy przedstawiono wyniki symulacji komputerowej działania czujnika elektrokatalitycznego. Do badań wykorzystano program D. Gossera opierający się na metodzie różnic skończonych.
-
Voltage and Current Unbalance Reduction in Power Networks with Distributed Generation and Electric Vehicles
PublikacjaThe current development of prosumer microsources and the expected spread of electric vehicles may cause the appearance of significant current and voltage unbalance in low-voltage (LV) networks. This unbalance, which is an unfavorable phenomenon, may occur when using single-phase photovoltaic (PV) microsources and single-phase home chargers for electric vehicles. This paper presents a proposal for the symmetrization of the LV network...
-
Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors
PublikacjaThis paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublikacjaThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublikacjaW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Common-Mode Voltage and Bearing Currents in PWM Inverters: Causes, Effects and Prevention
PublikacjaIn modern induction motor drives an increase of transistors' switching frequency and a decrease of switching times are the sources of some serious problems. The high dv/dt and the common mode voltage generated by the inverter PWM control results in the appearances of bearing currents, shaft voltages, motor terminal overvoltages, the decrease of motor efficiency, and electromagnetic interference. The aspects of common mode (CM)...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaPrzedstawiono nową metodę detekcji i lokalizacji uszkodzeń polegających na braku przewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne. Metoda jest rozszerzeniem, opracowanej wcześniej, metody wykorzystującej znormalizowane składowe stałe prądów obciążenia. Znormalizowane wartości średnie prądów powiązano z dodatkowymi wskaźnikami diagnostycznymi, które zawierają informacje o czasie trwania nieprzewodzenia...
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublikacjaW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
Response of high voltage disconnector under seismic excitation - experimental and numerical study
PublikacjaThe efficiency of the energetic infrastructure system is a very import safety issue in the region experienced by the ground motion. The aim of the present paper is to show the results of the experimental and numerical study focused on the earthquake-induced response of the high voltage disconnector, which is an important element of energetic network. First, the impact tests as well as the sweep-sine shaking table tests were conducted....
-
Output-capacitorless low-dropout regulator using a cascoded flipped voltage follower
PublikacjaPrzedstawiono udoskonaloną konfigurację wtórnika napięciowego w odwróconej konfiguracji oraz jej zastosowanie w regulatorze o małym spadku napięcia. W pracy przedstawiono teoretyczną analizę podstawowych parametrów wtórnika oraz regulatora napięcia. Ponadto przedstawiono wyniki pomiarów parametrów prototypowego układu scalonego wykonanego z użyciem technologii CMOS 0.35 um. Uzyskane wyniki porównano z rezultatami uzyskanymi w innych...
-
Modification of current-voltage characteristics of planar organic systems by nm-thick interlayer
PublikacjaEffect of nm-thick interlayer of copper phthalocyanine (CuPc) or perylene dye (MePTCDI) on current-voltage characteristics of planar organic systems is discussed in the work. The MePTCDI layer strongly limits injection of holes from ITO into CuPc, while CuPc limits injection of electrons from ITO into MePTCDI. In the systems with CuPc/MePTCDI heterojunction an explicit photovoltaic effect occurs.
-
Dynamic variables limitation for backstepping control of induction machine and voltage source converter
PublikacjaDynamic variables limitation for backstepping control of induction machine and voltage source converter The paper presents the method of control of an induction squirrel-cage machine supplied by a voltage source converter. The presented idea is based on an innovative method of the voltage source converter control, consisting in direct joining of the motor control system with the voltage source rectifier control system. The combined...
-
Computer-Aided Calculations of Earth Potential Rise in High Voltage Overhead Lines
PublikacjaHigh voltage overhead power lines with earth wires comprise towers made of conductive material. Some towers are in locations where people can be expected to be either for a long time or for a short time but very frequently. Evaluation of shock hazard near such towers requires calculation of line-to-earth short-circuit current, earth current and especially earth potential rise. Number of towers in high voltage power lines can exceed...
-
Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids
PublikacjaThis paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.
-
Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors
PublikacjaThis paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the...
-
Distribution Transformer with Multi-Zone Voltage Regulation for Smart Grid System Application
PublikacjaThe article presents four concepts of the multi-zone voltage regulation (MZVR) system. It is a combination of a distribution transformer with an on-load tap-changer, for step voltage regulation, and a power electronic converter, dimensioned for a fraction of MZVR power, realizing continuous voltage regulation, supplemented by a special switch, the so-called bypass. This allows voltage regulation at high resolution, wide range and...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublikacjaOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublikacjaThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Analysis of Ferroresonance Mitigation Effectiveness in Auxiliary Power Systems of High-Voltage Substations
PublikacjaFerroresonance in power networks is a dangerous phenomenon, which may result in overcurrents and overvoltages, causing damage to power equipment and the faulty operation of protection systems. For this reason, the possibility of the occurrence of ferroresonance has to be identified, and adequate methods need to be incorporated to eliminate or reduce its effects. The aim of this paper is to evaluate the effectiveness of ferroresonance...
-
Temperature effect on the current-voltage characteristic fill factor for the silicon solar cells
PublikacjaW pracy przedstawiono badania wpływu temperatury pracy krzemowych ogniw fotowoltaicznych na wartość współczynnika wypełnienia charakterystyki prądowo- napięciowej (FF). Efekty dyfuzyjne w obszarze złącza oraz rekombinacja nośników ładunku ograniczają wartość współczynnika wypełnienia charakterystyki. Spadek tej wartości wynika głównie ze wzrostu wartości rezystancji szeregowej rs. Na rezystancję szeregową składają się: opór emitera...
-
Protection against electric shock in electrical installations with low voltage generating sets
PublikacjaW referacie przedstawiono zasady ochrony przeciwporażeniowej, zgodne z wymaganiami międzynarodowymi, w sytuacji kiedy instalacja elektryczna jest zasilana z niskonapięciowych zespołów prądotwórczych. Zwrócono uwagę na dobór zabezpieczeń przeciwporażeniowych oraz na wymiarowanie uziemień.
-
Balancing Energy Inputs/Outputs and GHG Emissions for Sustainable Wastewater Treatment – a Case Study
PublikacjaThe aim of the study is a model-based evaluation of the selected operating modes and technological upgrades on the energy balance and greenhouse gas (GHG) emissions in a large wastewater treatment plant in the city of Slupsk (northern Poland). The considered scenarios focus on energy savings for aeration, increasing energy recovery via biogas cogeneration and reduction of the CO2 equivalent emission from both direct processes (related...
-
A selection of PID type controller settings via LQR approach for two-wheeled balancing robot
PublikacjaThe problem of PID type controller tuning has been addressed in this paper. In particular, a method of selection of PD settings based on the solution of linear–quadratic optimisation problem using the energy criterion has been investigated. Thus, the possibility of transforming optimal settings of the linear–quadratic regulator into the settings of the controller in the classical control system has been given. The presented methodology...
-
Estimation of the angular position of a two-wheeled balancing robot using a real IMU with selected filters
PublikacjaA low-cost measurement system using filtering of measurements for two-wheeled balancing robot stabilisation purposes has been addressed in this paper. In particular, a measurement system based on gyroscope, accelerometer, and encoder has been considered. The measurements have been corrected for deterministic disturbances and then filtered with Kalman, α-β type, and complementary filters. A quantitative assessment of selected filters...