Filtry
wszystkich: 1743
wybranych: 1348
-
Katalog
- Publikacje 1348 wyników po odfiltrowaniu
- Czasopisma 3 wyników po odfiltrowaniu
- Konferencje 1 wyników po odfiltrowaniu
- Osoby 8 wyników po odfiltrowaniu
- Projekty 3 wyników po odfiltrowaniu
- Kursy Online 2 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 377 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: TI13ZR13NB ALLOY
-
Morphology and properties of nanotubular oxide layer on the Ti13Zr13Nb alloy
PublikacjaThe Ti13Zr13Nb alloy in solid and porous form was oxidised. The constant voltage 20 V, oxidation time 0.5 and 1 h, and 1 M H3PO4 (orthophosphoric acid) with addition of HF (hydrofluoric acid) as a test solution were applied. SEM (Scanning Electron Microscope) examinations of surface, EDS (Energy Dispersive X-ray Spectroscopy) chemical analysis, nanohardness and nano-scratch tests, and corrosion potentiokinetic tests at various...
-
THE PROPERTIES OF NANOSILVER – DOPED NANOHYDROXYAPATITE COATING ON THE Ti13Zr13Nb ALLOY
PublikacjaThe aim of this research was to study the properties of nanohydroxyapatite (nanoHAp) and nanohydroxyapatite, doped with nanosilver (nanoHAp/nanoAg), coatings obtained by an electrophoretic deposition process. The suspensions was prepared by dispersing 0.1 g of HAp nanopowder for nanoHAp coatings and 0.1 g of nanoHAp and 0.025 g nanoAg for nanoHAp/nanoAg coatings. The deposition was carried out for 1 min at 50 V voltage followed...
-
Electrophoretic deposition (EPD) of nanohydroxyapatite - nanosilver coatings on Ti13Zr13Nb alloy
PublikacjaTitanium and its alloys are the biomaterials most frequently used in medical engineering, especially as parts of orthopedic and dental implants. The surfaces of titanium and its alloys are usually modified to improve their biocompatibility and bioactivity, for example, in connection with the deposition of hydroxyapatite coatings. The objective of the present research was to elaborate the technology of electrophoretic deposition...
-
The determinants of morphology and properties of the nanohydroxyapatite coating deposited on the Ti13Zr13Nb alloy by electrophoretic techniqe
PublikacjaThe titanium and its alloys belong at present to the most preferred and commonly applied biomaterials for load- bearing implants. The surfaces of biomaterials are subjected to modification, including the hydroxyapatite coatings deposited in order to ensure corrosion resistance and better joining between an implant and a bone through the possibility of ingrowth bone into the coating. In this paper, the morphology and properties...
-
Properties of Nanohydroxyapatite Coatings Doped with Nanocopper, Obtained by Electrophoretic Deposition on Ti13Zr13Nb Alloy
PublikacjaNowadays, hydroxyapatite coatings are the most common surface modification of long-term implants. These coatings are characterized by high thickness and poor adhesion to the metallic substrate. The present research is aimed at characterizing the properties of nanohydroxyapatite (nanoHAp) with the addition of copper nanoparticle (nanoCu) coatings deposited on the Ti13Zr13Nb alloy by an electrophoresis process. The deposition of...
-
The Influence of Nanometals, Dispersed in the Electrophoretic Nanohydroxyapatite Coatings on the Ti13Zr13Nb Alloy, on Their Morphology and Mechanical Properties
PublikacjaIn this work, nanohydroxyapatite coatings with nanosilver and nanocopper have been fabricated and studied. The presented results concern coatings with a chemical composition that has never been proposed before. The present research aims to characterize the effects of nanosilver and nanocopper, dispersed in nanohydroxyapatite coatings and deposited on a new, non-toxic Ti13Zr13Nb alloy, on the physical and mechanical properties of...
-
Effects of solution composition and electrophoretic deposition voltage on various properties of nanohydroxyapatite coatings on the Ti13Zr13Nb alloy
PublikacjaThe purpose of the research was to establish the influence of the solution composition and the electrophoretic deposition voltage on the coating homogeneity and thickness, nanohardness, adhesion, corrosion resistance and wettability. The Ti13Zr13Nb alloy was coated by the electrophoretic technique with hydroxyapatite in a solution containing 0.1, 0.2 or 0.5 g nanoHAp in 100 mL of suspension and at voltage 15, 30 or 50 V. The scanning...
-
The Chemical and Biological Properties of Nanohydroxyapatite Coatings with Antibacterial Nanometals, Obtained in the Electrophoretic Process on the Ti13Zr13Nb Alloy
PublikacjaThe risk of an early inflammation after implantation surgery of titanium implants has caused the development of different antimicrobial measures. The present research is aimed at characterizing the effects of nanosilver and nanocopper dispersed in the nanohydroxyapatite coatings, deposited on the Ti13Zr13Nb alloy, and on the chemical and biological properties of the coatings.The one-stage deposition process was performed by the...
-
Properties of chitosan/CuNPs coatings electrophoretically deposited on TiO2 nanotubular oxide layer of Ti13Zr13Nb alloy
PublikacjaCoatings based on chitosan/CuNPs (chit/CuNPs) were obtained by a one-step electrophoretic deposition (EPD) on nanotubular oxide layer of Ti13Zr13Nb alloy. The deposition was carried out for 1 min applying voltages of 10 and 20 V with and without the addition of dispersing agent (Polysorbate 20) to the suspension. The coatings obtained for the lower voltage were more uniform than for the higher voltage. By adding a dispersing agent,...
-
Biological and antibacterial properties of chitosan-based coatings with AgNPs and CuNPs obtained on oxidized Ti13Zr13Nb titanium alloy
PublikacjaDespite numerous studies, the antibacterial efficiency and cytotoxicity of chitosan-based coatings with nanometals need further studies. The purpose of this research was to determine the biological properties of chitosan coatings implemented with either silver nanoparticles (AgNPs) or copper nanoparticles (CuNPs), that were electrophoretically deposited on electrochemically oxidized Ti13Zr13Nb alloy. The SEM tests were used to...
-
Effects of electrophoretic deposition times and nanotubular oxide surfaces on properties of the nanohydroxyapatite/nanocopper coating on the Ti13Zr13Nb alloy
PublikacjaLoad-bearing implants are developed with a particular emphasis placed on an application of ceramic hydroxyapatite coatings in order, to enhance the bioactivity of titanium implants and to shorten the healing time. Therefore, thin, fully crystalline coatings that are, highly adhesive, hydrophilic and demonstrating antibacterial properties are ly looked for. The aim of this research was to develop and characterize the properties...
-
The Effect of Surface Modification of Ti13Zr13Nb Alloy on Adhesion of Antibiotic and Nanosilver-Loaded Bone Cement Coatings Dedicated for Application as Spacers
PublikacjaSpacers, in terms of instruments used in revision surgery for the local treatment of postoperative infection, are usually made of metal rod covered by antibiotic-loaded bone cement. One of the main limitations of this temporary implant is the debonding effect of metal–bone cement interface, leading to aseptic loosening. Material selection, as well as surface treatment, should be evaluated in order to minimize the risk of fraction...
-
Effects of Micro-Arc Oxidation Process Parameters on Characteristics of Calcium-Phosphate Containing Oxide Layers on the Selective Laser Melted Ti13Zr13Nb Alloy
PublikacjaTitania-based films on selective laser melted Ti13Zr13Nb have been formed by micro-arc oxidation (MAO) at different process parameters (voltage, current, processing time) in order to evaluate the impact of MAO process parameters in calcium and phosphate (Ca + P) containing electrolyte on surface characteristic, early-stage bioactivity, nanomechanical properties, and adhesion between the oxide coatings and substrate. The surface...
-
Innowacyjna powłoka poprawiająca własności mechaniczne oraz biokompatybilne stopów tytanu Ti6Al4V i Ti13Zr13Nb przeznaczonych na implanty wewnetrzne
PublikacjaOstatnie badania nad materiałami tytanowymi przeznaczonymi na implanty wewnętrzne pokazują iż dotychczas uznawany za bezinwazyjny tytan odkłada się w organizmie. Nie wiadomo jeszcze jakie konsekwencje są tego procesu dla organizmu żywego. W artykule przedstawiono idee wytworzenia nowej, biokompatybilnej powłoki, która ma na celu zminimalizowanie przenikania jonów metalu do organizmu ludzkiego oraz ułatwienie porastania implantu...
-
Elasto-viscoplastic properties of AA2017 aluminium alloy
PublikacjaArtykuł opisuje procedurę identyfikacji parmetrów materiałowych dla sprężysto-lepkoplastycznego modelu Bodnera-Partoma. Prezentowane są symulacje numeryczne testów jednoosiowego rozciągania z różnymi prędkościmi odkształcenia, które porównane są z wynikami eksperymantalnymi.
-
Tracking of the Multimodal Ordering Process in FePd Alloy
Publikacja -
Internal friction in FePd alloy during ordering
PublikacjaStwierdzono występowanie wysokiego poziomu tarcia wewnętrznego w zahartowanym stopie FePd (50% at. Pd). Zbadano proces uporządkowania atomowego w korelacji ze zmianami tarcia wewnętrznego defektu modułu i relaksacji magnetycznej stopu porządkującego się podczas nagrzewania do 900 K. Zaobserwowano efekt prędkości nagrzewania na punkt Curie.
-
Phase investigations of copper based CuZn38Al2MnFe alloy
PublikacjaW pracy przedstawiono analizę fazową mosiądzu CuZn38Al2MnFe. Wykazano, że obecność fazy Fe4Mn77Si19 powoduje kruchość stopu w teście zginania próbek.
-
Elctrochemical oxidation and corrosion resistance of the Ti13Nb13Zr alloy
PublikacjaThis paper presents the results of oxidation and corrosion tests carried out on titanium alloy Ti13Nb13Zr. The oxide film was prepared by electrochemical environment 2M H3PO4 for 30 min and 1 h, at a constant voltage 40V. The tests of corrosion resistance were performed by potentiostatic method in Ringer's solution at different pH values: 7, 5 and 3. The change in an appearance of surface and the increase in corrosion resistance...
-
Properties of Composite Oxide Layers on The Ti13Nb13Zr Alloy
PublikacjaThe development of composite oxide layers on the Ti13Nb13Zr alloy, their structure and properties have been demonstrated. Two subsequent methods were applied to prepare the composite layers. During the first stage gas oxidation produced a solid oxide layer, and subsequently oxide nanotubes were produced by using an electrochemical method. Scanning electron microscopy (SEM), chemical analysis, energy dispersive X-ray spectroscopy...
-
Environmental degradation of titanium alloy in artificial saliva
PublikacjaThe titanium and its alloys are potentially prone to hydrogen embrittlement, including those proposed for dental implants. The research has been aimed to assess a susceptibility to environment-enhanced degradation of the Ti-13Zr-13Nb alloy in artificial saliva with or without hydrofluoric acid, subject or not to cathodic polarisation. The results have shown that even if artificial saliva is safe environment, both cathodic polarization...
-
Hydroxyapatite deposition on the laser modified Ti13Nb13Zr alloy
PublikacjaThe Ti13Nb13Zr alloy was subjected to laser modification with the Nd:YAG laser provided that such treatment would increase the surface roughness followed improved adhesion of hydroxyapatite (HAp) coatings The hydroxyapatite was deposited by electrophoretic method in suspension of 0.5 g HA powder and 100 ml ethyl alcohol. The deposition was carried out for 10 min at 10 V voltage followed by drying at room temperature for 24 h and...
-
Oxidation and hydrogen behavior in Zr-2Mn alloy
PublikacjaThe purpose of the present research was to determine the oxidation and hydrogenation behavior in the new Zr-2Mn alloy. The oxidation of alloy was performed at temperatures between 350°C and 900°C for 30 minutes. The hydrogen charging was made for 72 h at a current density 80 mA/cm2. The charged samples were heat treated at 400°C for 4 h to obtain a uniform hydrogen profile content across the sample. The oxidation resulted in an...
-
Laser Welding of UNS S33207 Hyper-Duplex Stainless Steel to 6061 Aluminum Alloy Using High Entropy Alloy as a Filler Material
PublikacjaThe high entropy alloy (HEA) filler used during the fabrication method determines the reliability of HEAs for steel-aluminum dissimilar alloy configuration. HEAs have a direct impact on the formation of intermetallic compounds (IMC) formed by the interaction of iron (Fe) and aluminum (Al), and influence the size of the joint’s interaction zone. A novel welding process for Fe-Al alloy joints was developed to prevent the development...
-
Surface treatment of porous Ti13Nb13Zr alloy for biomedical applications
PublikacjaPrzeprowadzono badania materiału porowatego, przeznaczonego na implanty ortopedyczne, wytworzonego metodą metalurgii proszków ze stopu Ti13Nb13Zr. Proszki z badanego stopu uzyskano metodą rozpylania plazmowego. Otrzymano próbki o otwartej porowatej strukturze, stopniu porowatości do 68% i średniej wielkości porów w przedziale 30-150 mikrometrów. Obróbka próbek porowatych - utlenianie termiczne, chemiczne i/lub elektrochemiczne...
-
Cavitation behavior of the SUPERSTON alloy after laser treatment
PublikacjaResults of laser treatment at cryogenic conditions and its influence on microstructure, microhardness and cavitation resistance of the SUPERSTON alloy are presented in this paper. Obtained results point at possibility of the increase hardness and cavitation resistance of the parts worked in cavitation conditions.
-
Influence of the heat treatment on corrosion characteristics of the Superston alloy
PublikacjaW artykule przedstawiono wpływ hartowania i odpuszczania na twardość i właściwości korozyjne stopu Superston, stosowanego na śruby okrętowe. Stwierdzono, iż hartowanie z temperatury 900 st.C i odpuszczanie w temperaturze 550 st.C znacząco podwyższa odporność na korozję stopu Superston w 3% roztworze NaCl w porownaniu ze stanem odlanym.
-
Underwater robot actuated by shape memory alloy wires
PublikacjaW pracy przedstawiono koncepcję projektu robota podwodnego z napędem wykorzystującym materiały SMA ze stopów z pamięcią kształtu. Rozpatrywany układ ma budowę modułową złożoną z segmentów na podobieństwo do anatomicznej budowy dżdżownicy. Pojedyńczy segment składa się z dwóch okrągłych tarcz, pomiędzy którymi umieszczono balon wypełniony wodą. Wielkość balonu jest dopasowana w taki sposób do rozmiarów tarcz oraz długości sprężyn...
-
Special Issue “Corrosion Resistance of Alloy and Coating Materials”
Publikacja -
EXPERIMENTAL EVALUATION OF THE EMISSIVITY OF A NITI SHAPE MEMORY ALLOY
Publikacja -
Influence of Staphylloccoccus bacteria adhesion on the degradation of the Ti6Al4V alloy
PublikacjaThe paper deals with bacteria adhesion and the degradation of the Ti6Al4V alloy
-
Microstructure and corrosion properties of the laser treated SUPERSTON alloy
PublikacjaPrzedstwiono wyniki laserowego nadtapiania powierzchni stopu SUPERSTON w warunkach kriogenicznych. Zaprezentowano obraz powierzchni stopu po badaniach korozyjnych oraz wyniki pomiarów mikrotwardości i odporności korozyjnej.
-
High temperature corrosion resistance of porous hastelloy alloy
PublikacjaTo further understand the suitability of Ni-Cr-base alloy for solid oxide fuel cell (SOFC), a commercial Ni-Cr-Fe-Mo alloy, Hastelloy X was selected and evaluated for oxidation behaviour under high temperature conditions. HastelloyX was chosen due to its unusual resistance to oxidizing, reducing and neutral atmospheres. For long term stability of metal supported fuel cell, the corrosion resistance plays a vital role and must be...
-
Porous biomaterial for orthopaedic implants based on titanium alloy
PublikacjaTytan i jego stopy są szeroko stosowane jako biomateriały dla zastosowań ortopedycznych. Badania związane z ich najlepszą odpornością na korozję i ścieranie, biozgodnością i bioaktywnością są stale prowadzone. Obecne badania koncentrują się również na projektowaniu i produkcji materiałów porowatych w oparciu o stopy np. Ti-13Nb-13Zr, które mogą być stosowane do wytwarzania implantów. Jedną z najbardziej efektywnych metod wytwarzania...
-
High temperature corrosion resistance of porous hastelloy alloy
PublikacjaW pracy przedstawiono badania korozyjne stopu Hastelloy w wysokich temperaturach.
-
Assessment of FSW Welds Made of Aluminum Alloy AW7075-T651.
PublikacjaThis paper summarizes the results of experimental studies in which the aluminum alloy AW7075-T651 was friction stir welded (FSW) using various combinations of process parameters (rotational - R and travel speed - T). Mechanical properties of the test welds were assessed by using static tensile test and Vickers hardness measurement. The temperature of the welded plates was monitored during welding by means of thermocouples placed...
-
Electrochemical impedance studies of AB5 -type hydrogen storage alloy
PublikacjaDo wyznaczenia własności stopu AB5 wykorzystano elektrochemiczną spektroskopie impedancyjną. Badania impedancyjne wykonano podczas chronowoltamperometri cyklicznej oraz cykli ładowania i rozładowania elektrody. Interpretacja uzyskanych w trybie potencjostatycznym wyników pozwoliła na dalszą interpretacje wyników uzyskanych w trybie galwanostatycznym. Proponowana metodologia umożliwia śledzić parametry elektryczne badanego układu...
-
Preparation of the porous biomaterial based on titanium alloy for orthopaedic implants
PublikacjaObecnie tytan i jego stopy (Ti-6Al-4V lub Ti-13Nb-13Zr) są szeroko stosowane jako biomateriały dla implantów ortopedycznych. Stale prowadzone są badania nad ich najlepszą odpornością na korozję i zużycie ścierne oraz biozgodnością i bioaktywnością. Obecne badania również skoncentrowane są na projektowaniu, wytwarzaniu i właściwościach materiałów porowatych na podstawie na przykład stopu tytanu (Ti-13Nb-13Zr), które mogą być stosowane...
-
Preparation of nano-tubular oxide layers on titanium alloy Ti13Nb13Zr
PublikacjaThe article presents results of oxidation tests and corrosion investigations of titanium alloy Ti13Nb13Zr preformed at different conditions. The oxide layers have been formed using electrochemical method in 2M H3PO4 + 0,3% HF solution for 30 min. and 1h at 20V constant voltage. The corrosion tests heve been made with poteniodynamic method in Ringer's solution at pH ranged 3 and 7. It has been shown that the nano-oxide films, which...
-
Surface cracking of laser melted Ti-6Al-4V alloy
PublikacjaOpisano charakterystyczne cechy pękania powierzchniowego obserwowanego po nadtapianiu laserem CO2 i Nd:YAG stopu Ti-6Al-4V. Obserwowano pęknięcia niezależnie od sposobu nadtapiania, penetrujące głęboko strefę przetopioną i w niewielkim stopniu zależne od sposobu nadtapiania. Przypisano obserwowane zjawisko przemianie martenzytycznej i (lub) naprężeniom cieplnym powstającym podczas gwałtownego chłodzenia.
-
Assessment of cavitation erosion damage of laser remelted the SUPERSTON alloy
PublikacjaW artykule przedstawiono wpływ obróbki laserowej w warunkach kriogenicznych na mikrostrukturę stopu SUPERSTON po badaniach kawitacyjnych. Badania odporności kawitacyjnej przeprowadzono na stanowisku z wirującą tarczą w IMP PAN Gdańsk. Określono kinetykę ubytku masy próbek podczas testu kawitacyjnego dla stopu odlanego i nadtopionego laserowo.
-
Electrochemical investigations of Al-Mg alloy subjected to tensile test
PublikacjaWykonano pomiary elektrochemiczne stopu typu Al-Mg podczas badań mechanicznych polegających na rozciąganiu badanych próbek. W trakcie badań mechanicznych wykonywano badania za pomocą metody dynamicznej spektroskopii impedancyjnej (DEIS). Stwierdzono, że podczas realizacji rozciągania próbek zachodzi proces pękania warstwy pasywnej w wyniku którego rozpoczynają się procesy korozyjne. W zakresie plastycznym podczas rozciągania zarejestrowano...
-
Electrochemical investigations of Al–Mg alloy subjected to tensile test
Publikacja -
Impedance analysis of Portevin-Le Chatelier effect on aluminium alloy
Publikacja -
Electrochemical impedance studies of AB5-type hydrogen storage alloy
Publikacja -
Impedance analysis of Portevin-Le Chatelier effect on aluminium alloy
PublikacjaW niniejszej pracy przeprowadzono badania elektrochemiczne powierzchniowego efektu PLC, związanego z nierównomiernym procesem płynięcia plastycznego stopów aluminium zawierających magnez. Występujący efekt PLC w postaci serration wywołuje niehomogeniczny proces zmian zewnętrznej powierzchni rozciąganej próbki. Wykonano badania metodą Dynamicznej Spektroskopii Impedancyjnej w warunkach dynamicznych prowadzenia procesu rozciągania....
-
Microstructural aspects of corrosion of the SUPERSTON alloy after laser treatment
PublikacjaW artykule przedstawiono rezultaty obróbki laserowej stopu SUPERSTON w warunkach kriogenicznych i jej wpływ na mikrostrukturę i odporność korozyjną. Badania korozyjne zostały zrealizowane metodą potencjostatyczną w 3% NaCl, odporność korozyjna stopu zmieniała się wraz ze zmianą parametrów nadtapiania laserowego.
-
Feasibility study of a novel hot stamping process for Ti6Al4V alloy
Publikacja -
Fractal analysis of the bending-torsion fatigue fracture of aluminium alloy
Publikacja -
Chemical order and crystallographic texture of FePd:Cu thin alloy films
Publikacja