Filtry
wszystkich: 5305
-
Katalog
- Publikacje 3789 wyników po odfiltrowaniu
- Czasopisma 44 wyników po odfiltrowaniu
- Konferencje 7 wyników po odfiltrowaniu
- Osoby 55 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 27 wyników po odfiltrowaniu
- Dane Badawcze 1380 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: HEMATOCRIT MEASUREMENT
-
Displacement measurements during load testing of railway arch bridge
PublikacjaThe paper discusses issues concerning load tests carried out on a twin-track, arch railway bridge over the Martwa Wisla river in Gdansk. Currently, it is the bridge with the longest span in its class in Poland. The load-bearing structure consists of three no-hinge arches and an orthotropic deck suspended from them. The studies of the structure assumed the performing of static and dynamic tests. The paper presents the method for...
-
Impedancyjne badanie korozji wżerowej. Impedance measurements of pitting corrosion
PublikacjaKryteria zachodzenia korozji wżerowej związane są z badaniami tego zjawiska metodą cyklicznej polaryzacji i opierają się na wartości gęstości prądu lub bezwzględnej wartości prądu płynącego w układzie. Na podstawie przeglądu literaturowego wybrano cztery kryteria stosowane przy badaniu stali stopowych metodą cyklicznej polaryzacji. Dla warunków prądowych odpowiadających kryteriom zachodzenia korozji wżerowej przedstawiono widma...
-
Detection of dental lessions by means of immittance measurements - an in vitro study
PublikacjaW pracy przedstawiono stanowisko do badań in vitro przewodności tkanek zęba.
-
A Comparability of Renal Length and Volume Measurements in MRI and Ultrasound in Children
PublikacjaIntroduction: Despite the significant increase in use of magnetic resonance imaging (MRI) in children, there is still a lack of normal reference values of renal size in this method and reference values are being interpolated from the ultrasound (US) studies. The study provides comparative analysis of agreement in renal length and volume measurements between MRI and ultrasound. Materials and Methods: Ninety-three children with a...
-
Adaptive Wavelet-Based Correction of Non-Anechoic Antenna Measurements
PublikacjaNon-anechoic measurements represent an affordable alternative to evaluation of antenna performance in expensive, dedicated facilities. Due to interferences and noise from external sources of EM radiation, far-field results obtained in non-ideal conditions require additional post-processing. Conventional correction algorithms rely on manual tuning of parameters, which make them unsuitable for reliable testing of prototypes. In this...
-
Investigation of the Few‐Layer Black Phosphorus Degradation by the Photonic Measurements
PublikacjaFew-layer black phosphorus (FLBP) is a 2D material that gains worldwide interest for its possible applications, mainly in electronics and optoelec-tronics. However, as FLBP is prone to a degradation process under envi-ronmental conditions, there is a need for a monitoring method allowing investigation of its surface quality. Among many techniques, optoelectronic ones have unique advantages of fast response, non-contact, and non-invasive...
-
Measurements and Analysis of Motor Supplying Current Waveform for Diagnostic Purposes
PublikacjaPodano proponowaną metodę diagnostyki łożysk tocznych w silnikach indukcyjnych poprzez pomiar i analizę prądu zasilającego. Przedstawiono opracowany system pomiarowy oraz wyniki badań na łożyskach o specjalnie wprowadzonych uszkodzeniach.
-
Optical time of flight spectroscopy for highly scattering materials measurements.
PublikacjaW artykule omówiono możliwości wykorzystania optycznej spektroskopii czasu przelotu w wyznaczaniu podstawowych parametrów optycznych materiałów silnie rozpraszających światło. Wykorzystano tu metodę Monte Carlo i metodę dyfuzji.
-
On the power systems performance control starting from disturbances measurements
PublikacjaReferat przedstawia badanie działania układu sterowania w systemie elektroenergetycznym oparte na oszacowanie parametrów. Na podstawie pomiarów wykonanych w stanie zakłóconiowym, parametry te są oszacowane minimizując uchyb pomiędzy wartościami wielkości uzyskanych z pomiarów i wartościami wielkości wyjściowych modelu systemu elektroenergetycznego. W celu zmniejszenia tego uchybu, proponowano dwie metody: klasyczna oparta na czułości...
-
Optical measurements for thin oil film investigation in rheometric processes.
PublikacjaPrzedmiotem badań jest pomiar parametrów cienkiej warstwy oleju silikonowego AK106, powstającej na ścianach dyszy w trakcie procesu reologicznego wyciskania do form past ceramicznych, przygotowywanych ze sproszkowanego tlenków wodorotlenków AlOOH oraz oleju AK106. Parametrami badanymi były: grubość warstwy oleju, charakterystyka reflektancyjna pasty oraz skład mieszaniny. Przedstawione zagadnienie ma istotne znaczenie dla rozwoju...
-
Methods for displacement and rotation measurements of individual Taylor-Schneebeli grains.
PublikacjaW artykule przedtawiono autorską metodę pomiaru przemieszczeń oraz obrotów cząstek ośrodka analogowego Taylor-Schneebeli oraz propozycję interpretacji badań.
-
Non contact multiband emissivity measurment. bibliogr.Optoelectronic and Electronic Sensors.
PublikacjaW pracy zaproponowano i opisano wielopasmowa pasywną metodę pomiaru emisyjności obiektu. W oparciu o opracowany model matematyczny przeprowadzona została analiza systemu pomiarowego. Wyniki modelowania umożliwiają ocenę dokładności projektowanego systemu.
-
Mean of continuous variables observable via measurment on a single qubit.
PublikacjaWykazano, że pomiar wartości średniej obserwabli kwantowej można dokonać poprzez pomiar uogólniony przy użyciu pojedynczego bitu kwantowego. Wyprowadzony schemat poddano dyskusji w kontekście paradygmatu odległych laboratoriów oraz nierówności Bella.
-
Measurement of dynamic pulsations in bulk solid during silo discharging using ECT method
PublikacjaW pracy przedstawiono wyniki pomiarów pulsacji materiału sypkiego pomieroznych z zastosowaniem metody pomiarowej ECT. Analizę dynamicznych zmian koncetracji przperowadzono dla podstawowych(surowych) danych pomiarowych oraz danych zrekonstruowanych
-
Electrochemical sensor for measurement of volatile organic compounds employing square wave perturbation voltage
PublikacjaThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde in air. Sensitivity and limit of quantification of the sensor were determined for different internal electrolyte using the square wave voltammetry (SWV) as a detection technique. The working and counter electrodes were made of platinum. Ionic liquids 1-hexyl, 3-methylimidazolium chloride,1-hexyl, 3-methylimidazolium bis (trifluoromethanesulfonyl)...
-
Method using bilinear transformation for measurement of impedance parameters of a multielement two-terminal network
PublikacjaArtykuł przedstawia metodę identyfikacji parametrów impedancyjnych obiektów modelowanych dwójnikami. Metoda wykorzystuje właściwości przekształcenia biliniowego pozwalającego na przedstawienie impedancji obiektu jako funkcji każdego z parametrów obwodu zastępczego z osobna. Odwrotne przekształcenie biliniowe pozwala na wyznaczenie wartości każdego parametru na podstawie pomiaru impedancji na jednej częstotliwości dobranej dla...
-
The critical rotational speed of circular saw: simple measurement method and its practical implementations.
PublikacjaProducenci pił tarczowych są zobligowani do podawania ich dopuszczalnych prędkości obrotowych. Jednakże, umieszczane przez nich prędkości na piłach są często bliskie prędkościom krytycznym lub je przewyższają. Przecinanie takimi narzędziami może być więc niebezpieczne dla obsługującego. Praca przedstawia prostą metodologię wyznaczania prędkości obrotowych krytycznych pił tarczowych. Badania były prowadzone z wykorzystaniem technik...
-
Strouhal Number Measurement for Novel Biomimetic Folding Fins Using an Image Processing Method
Publikacja -
Feature-Based Characterisation of Turned Surface Topography with Suppression of High-Frequency Measurement Errors
Publikacja -
Proposals of Frequency-Based and Direction Methods to Reduce the Influence of Surface Topography Measurement Errors
Publikacja -
Analysis of occurrence of guided disorders in selected railway equipment — impact of load on measurement results
Publikacja -
Application of the Least Squares Method to the approximation of equally spaced samples in frequency measurement approach
Publikacja -
The Influence of Noise Level on the Value of Uncertainty in a Measurement System Containing an Analog-to-Digital Converter
Publikacja -
Optimal Placement of Phasor Measurement Unit in Power System using Meta-Heuristic Algorithms
PublikacjaThe phasor measurement units (PMUs) play an important and vital role in power system monitoring and controlling, since they provide the power system phasors stamped with a common real time reference through a global positioning system (GPS). Indeed, from economical point of view it is not possible to set PMUs in all system buses due to the high cost and the requirement of more complex communication...
-
Interlaboratory comparison of methodologies for the measurement of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine
Publikacja -
Measurement of selected characteristics of low-coherence optical signal sources for optical coherence tomography
Publikacja -
Dynamic mass measurement in checkweighers using a discrete time-variant low-pass filter
PublikacjaConveyor belt type checkweighers are complex mechanical systems consisting of a weighing sensor (strain gauge load cell, electrodynamically compensated load cell), packages (of different shapes, made of different materials) and a transport system (motors, gears, rollers). Disturbances generated by the vibrating parts of such a system are reflected in the signal power spectra in a form of strong spectral peaks, located usually in...
-
Measurement of temperature-dependent viscosity and thermal conductivity of alumina and titania thermal oil nanofluids
PublikacjaThe results of simultaneous measurements of dynamic viscosity, thermal conductivity, electrical conductivity and pH of two nanofluids, i.e. thermal oil/Al2O3 and thermal oil/TiO2 are presented. Thermal oil was selected as a base liquid because of possible application in ORC systems as an intermediate heating agent. Nanoparticles were tested at the concentration of 0.1%, 1% and 5% by weight within temperature range from 20°C to...
-
Performance of DS-CDMA Radionavigation Receiver with Subsample Time Measurement Resolution in Various Environments
PublikacjaThis paper presents results of investigation of position estimation performance in TDOA radionavigation system with receiver containing code tracking loop with subsample time measurement resolution. Position estimation accuracy was evaluated using real signals from CDMA base stations, recorded during measurement campaigns in various environments: on sea, flat terrain and hilly terrain.
-
3D Sound Intensity Measurement Around Organ Pipes Using Acoustic Vector Sensors
PublikacjaThe aim of the presented paper was to obtain and visualize sound intensity distribution of radiated acoustic energy around the organ pipes. The experimental setup consisted of the multichannel acoustic vector sensor and the specialized Cartesian robot. Measurements were performed in free field with spatial resolution of 0.1 [m]. Two organ pipes, i.e. wooden and metal were measured during the ex-periment. The organ pipes were activated...
-
Factory Acceptance Test – Strain Gauge Measurement, Report no: WOiO /II/123/2014
PublikacjaTested object was 40 meters long jib and its foundation, placed in Gdansk Shiprepair Yard, manufactured by KMK. The contruction was dedicated to the passenger cruise vessel "Quantum of the Seas" The Strain Gauge measurement in different location and load situation was done in order to validate calculation finite element models used during strength analysis for project. The expertise contains: methodology of the measurements, description...
-
Factory Acceptance Test – Strain Gauge Measurement - Report no: WOiO /II/88/2014
PublikacjaTested object was 40 meters long jib and its foundation, placed in Gdansk Shiprepair Yard, manufactured by KMK. The contruction was dedicated to the passenger cruise vessel "North Star" The Strain Gauge measurement in different location and load situation was done in order to validate calculation finite element models used during strength analysis for project. The expertise contains: methodology of the measurements, description...
-
MEASUREMENT OF TEMPERATURE-DEPENDENT VISCOSITY AND THERMAL CONDUCTIVITY OF ALUMINA AND TITANIA THERMAL OIL NANOFLUIDS
PublikacjaIn this study results of simultaneous measurements of dynamic viscosity, thermal conductivity, electrical conductivity and pH of two nanofluids, i.e. thermal oil/Al2O3 and thermal oil/TiO2 are presented. Thermal oil is selected as a base liquid because of possible application in ORC systems as an intermediate heating agent. Nanoparticles were tested at the concentration of 0.1%, 1% and 5% by weight within temperature range from...
-
Discussion of Derivability of Local Residual Stress Level from Magnetic Stray Field Measurement
PublikacjaThe NDT procedure dubbed ‘metal magnetic memory’ method and the related ISO 24497 standard has found wide industrial acceptance in some countries, mainly in Russia and China. The method has been claimed by some researchers (Roskosz and Bieniek in NDT&E Int 45:55–62, 2012; Wilson et al. in Sens Actuators A 135:381–387, 2007) as having potential for quantitative determination of local residual stress state in engineering structures,...
-
Analysis of Transformation Methods of Hydroacoustic and Optoelectronic Data Based on the Tombolo Measurement Campaign in Sopot
Publikacja -
Modelling of Diffusing Capacity Measurement Results in Lung Microangiopathy Patients. A novel Diagnostic Suppport
PublikacjaLung microangiopathy is a little known negative influence of diabetes mellitus on the functioning of the lungs. The aim of this study is to design a supportive method for diagnosing lung microangiopathy. This will be based on routinely performed pulmonary measurements as well as on investigation process modelling and data processing. A model of the diffusion of oxygen from the alveoli to the blood has been described with a set...
-
Ellipse-fitting algorithm implementation in the impedance measurement system based on DAQ card with FPGA
PublikacjaThe paper presents an implementation of the ellipse-fitting algorithm in the impedance measurement system based on DAQ card equipped with FPGA chip. The method implementation was tested by simulation means as well as experimentally in the designed and presented measurement system. Finally, the limit values of sampling parameters which assures satisfying accuracy were given.
-
Analysis of Transformation Methods of Hydroacoustic and Optoelectronic Data Based on the Tombolo Measurement Campaign in Sopot
PublikacjaMeasurements in the coastal zone are carried out using various methods, including Global Navigation Satellite Systems (GNSS), hydroacoustic and optoelectronic methods. Therefore, it is necessary to develop coordinate transformation models that will enable the conversion of data from the land and marine parts to one coordinate system. The article presents selected issues related to the integration of geodetic and hydrographic data....
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublikacjaThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
The concept of estimation of elevator shaft control measurement results in the local 3D coordinate system.
PublikacjaGeodetic control measurements play an important part because they provide information about the current state of repair of the construction, which has a direct impact on the safety assessment of its exploitation. Authors in this paper have focused on control measurements of the elevator shaft. The article discusses the problem of determining the deviation of elevator shaft walls from the vertical plane in the local 3D coordinate...
-
Reduction of measurement data before Digital Terrain Model generation vs. DTM generalisation
PublikacjaModern data acquisition technologies provide large datasets that are not always necessary in its entirety to properly accomplish the goal of the study. In addition, such datasets are often cumbersome for rational processing, and their processing is time and labour consuming. Therefore, methods that enable to reduce the size of the measurement dataset, such as the generalization of the Digital Terrain Model (DTM) or the reduction...
-
Radioisotope measurement of selected parameters of liquid-gas flow using single detector system
PublikacjaTo determine the parameters of two-phase flows using radioisotopes, usually two detectors are used. Knowing the distance between them, the velocity of the dispersed phase is calculated based on time delay estimation. Such a measurement system requires the use of two gamma-ray sealed sources. But in some situations it is also possible to determine velocity of dispersed phase using only one scintillation probe and one gamma-ray source....
-
STUDY OF ARRAY OF MEMS INERTIAL MEASUREMENT UNITS UNDER QUASI-STATIONARY AND DYNAMIC CONDITIONS
PublikacjaA measurement system includes all components in a chain of hardware and software that leads from a measured variable to processed data. In that context, the type and quality of the sensors or measuring devices are critical to any measurement system. MEMS/IMU sensors lag behind leading technologies in this respect, but the MEMS/IMU performance rapidly changes while is relatively inexpensive. For this reason, the paper proposes...
-
Using On-line Measurement by Electronic Nose and Computer Simulations for Real-time Control at WWTP
PublikacjaContinuous investigation of wastewater quality can be carried out by a device called an e-nose. One important feature of the proposed real-time control system for WWTP is that using on-line measurements by e-nose together (Figure 1) with technological sets picked on this basis by means of computer models, it is possible to change treatment process parameters, depending on the current quality of wastewater. It can be used for the...
-
Measurement system for nonlinear surface spectroscopy by atomic force microscopy for corrosion processes monitoring
PublikacjaIn addition to traditional imaging the surface, atomic force microscopy (AFM) enables wide variety of additional measurements. One of them is higher harmonic imaging. In tapping mode the nonlinear contact between tip and specimen results in higher frequency vibrations. More information available from the higher harmonics analysis proves to be helpful for more detailed imaging. Such visualization is especially useful for heterogeneous...
-
Measurement of Seafloor Acoustic Backscatter Angular Dependence at 150 kHz Using a Multibeam Echosounder
PublikacjaAcoustic seafloor measurements with multibeam echosounders (MBESs) are currently often used for submarine habitat mapping, but the MBESs are usually not acoustically calibrated for backscattering strength (BBS) and cannot be used to infer absolute seafloor angular dependence. We present a study outlining the calibration and showing absolute backscattering strength values measured at a frequency of 150 kHz at around 10–20 m water...
-
Testing of Software for the Planning of a Linear Object GNSS Measurement Campaign under Simulated Conditions
PublikacjaThe precision of a linear object measurement using satellite techniques is determined by the number and the relative position of the visible satellites by the receiver. The status of the visible constellation is described by DOP. The obtained geometric coefficient values are dependent on many variables. When determining these values, field obstacles at the receiver location and satellite positions changing with time must be taken...
-
Determination of the uncertainty of mass flow measurement using the orifice for different values of the Reynolds number
PublikacjaStandard orifice flowmeters are widely used in the chemical and energy industry. Therefore, it is essential to know how accurate the measurements made with these instruments are. The paper presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. The authors will present the influence of ranges of the Reynolds number on the estimated uncertainty, obtained on the basis of simulation and laboratory...
-
A Measurement System for Quasi-Spectral Determination of Absorption and Scattering Parameters of Veterinary Tissue Phantoms
PublikacjaThis paper describes the construction of a system for the quasi-spectral determination of absorption and scattering parameters of animal tissue phantoms. Several tissue phantoms, including one reference and two modified for examination, were prepared from polydimethylsiloxane (PDMS). The phantoms were measured using a system based on an integrating sphere and the light sources of wavelengths commonly used for the treatment of various...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublikacjaIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...