Publikacje
Filtry
wszystkich: 422
Katalog Publikacji
Rok 2021
-
Plasmon-enhanced photoluminescence from TiO2 and TeO2 thin films doped by Eu3+ for optoelectronic applications
PublikacjaIn this work we study the luminescence properties of europium-doped titanium dioxide and tellurium oxide thin films enhanced by gold plasmonic nanostructures. We propose a new type of plasmon structure with an ultrathin dielectric film between plasmonic platform and luminescent material. Plasmonic platforms were manufactured through thermal annealing of the gold thin film. Thermal dewetting of gold film results in spherical gold...
-
Influence of plasmon resonance on the luminescence of titanium dioxide thin films doped with rare earth ions
PublikacjaIn this work the study of the optical properties of europium doped titanium dioxide thin films (TiO2:Eu) enhanced by gold plasmonic nanostructures are presented. Plasmonic platforms were manufactured by thermal annealing of thin film of Au, deposited on a Corning glass substrate. As a result of thermal treatment, gold spherical nanostructures with average dimensions of 50 nm were obtained. Luminescent TiO2:Eu film was deposited...
Rok 2020
-
The Luminescence of 1,8-Diazafluoren-9-One/Titanium Dioxide Composite Thin Films for Optical Application
Publikacja -
Preparation and Characterization of an Electrospun PLA-Cyclodextrins Composite for Simultaneous High-Efficiency PM and VOC Removal
Publikacja -
Electrodes criticality: the impact of CRMs in the leachate electrochemical oxidation
Publikacja
Rok 2019
-
Paving the Way for A Sustainable and Efficient SiO2/TiO2 Photocatalytic Composite
Publikacja -
Optical absorption and anisotropy of phosphorene flakes
Publikacja -
Electroadsorptive Removal of Gaseous Pollutants
Publikacja
Rok 2018
-
The Influence of LED Lighting Sources on the Nature of Power Factor
Publikacja -
Preparation and characterization of TiO2/carbon nanowall composite on a transparent substrate
Publikacja -
Indoor Air Quality: A Bibliometric Study
Publikacja -
Compressive Strength and Leaching Behavior of Mortars with Biomass Ash
Publikacja -
A Novel Method for the Combined Photocatalytic Activity Determination and Bandgap Estimation
Publikacja
Rok 2017
-
Non-Destructive Testing for the In Situ Assessment of the Ionic Flux in Cementitious Materials
Publikacja -
Influence of Binders and Lightweight Aggregates on the Properties of Cementitious Mortars: From Traditional Requirements to Indoor Air Quality Improvement
Publikacja -
Appraisal of a hybrid air cleaning process
Publikacja -
A special issue on Biophotonics in Europe
Publikacja
Rok 2016
-
Introductory investigations of dermatologic diode laser with wavelengths 975 nm: clinical therapy of Recklinghausen disease and of hemangiomas
Publikacja -
Application of thin dielectric films in low coherence fiber-optic Fabry-Pérot sensing interferometers: comparative study
Publikacja
Rok 2015
-
Enhanced capacitance of composite TiO2 nanotube/boron-doped diamond electrodes studied by impedance spectroscopy
Publikacja -
ALD thin ZnO layer as an active medium in a fiber-optic Fabry–Perot interferometer
Publikacja
Rok 2014
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
Publikacja -
Ranking of ecotoxisity tests for underground water assessment using the Hasse diagram technique
PublikacjaThe present study deals with the novel application of the Hasse diagram technique (HDT) for the specific ranking of ecotoxicity tests capable of assessment of underground water quality. The area studied is a multi-municipal landfill in the northern Poland. The monitoring network of the landfill constitutes of 27 piezometers for underground water monitoring and two observation points at surface water courses. After sampling, chemical...
-
Local impedance imaging of boron-doped polycrystalline diamond thin films
Publikacja
Rok 2013
-
Role of nitrogen in optical and electrical band gaps of hydrogenated/hydrogen free carbon nitride film
PublikacjaWe report the optical and electrical band gap energy of amorphous hydrogenated carbon nitride (a-HCNx) and carbon nitride (a-CNx) as a function of nitrogen concentration (N/C). The optical band gap of a-HCNx and a-CNx films has been determined by means of Ellipsometry and UV-VIS. Both optical and electrical band gaps increase with elevated nitrogen concentration. Experimentally obtained electrical band gap is compared with the...
-
Klawiatura ekranowa dla osób posługujących się jedną kończyną górną
Publikacjartykuł prezentuje układ symboli na klawiaturze wirtualnej dedykowanej osobom niepełnosprawnym posługującym się jedną kończyną górną. Rozmieszczenie znaków zostało ustalone na podstawie przeprowadzonej analizy częstotliwości występowania poszczególnych liter w języku polskim. Uwzględniono również najczęściej występujące pary liter, a odpowiadające im klawisze ułożono blisko siebie. Zaproponowany kształt klawiatury jest wynikiem...
-
Electrochemical oxidation of sulphamerazine at boron-doped diamond electrodes: Influence of boron concentration
Publikacja -
Application of Infrared Thermography to Non-Contact Testing of Varistors
Publikacja -
Amperometric sensing of chemical oxygen demand at glassy carbon and silicon electrodes modified with boron-doped diamond
Publikacja
Rok 2012
-
Wykorzystanie termowizji w badaniach odporności na udary wg EN61000-4-5
PublikacjaPrzedstawiono wyniki badań konstrukcyjnych urządzeń elektronicznych z zastosowaniem kamery podczerwieni do obserwacji obiektu badanego podczas badań odporności na udary napięciowe wykonywane wg normy EN61000-4-5.
-
Usage of Two-Center Basis Function Neural Classifiers in Compact Smart Resistive Sensors
PublikacjaA new solution of the smart resistance sensorwith the Two-Center Basis Function (TCBF) neuralclassifier, for which the resistance sensor is a component ofan anti-aliasing filter of an ADC is proposed. Thetemperature measurement procedure is based on excitationof the filter by square impulses, sampling time response ofthe filter and processing measured voltage values by theTCBF classifier. All steps of the measurement procedure...
-
Testowanie jakości warystorów niskonapięciowych
PublikacjaW pracy przedstawiono budowę warystorów, z uwzględnieniem procesów zachodzących w ich strukturach i prowadzących do zmiany ich parametrów elektrycznych oraz wybrane sposoby testowania ich jakości.
-
System monitorowania wyładowań elektrostatycznych
PublikacjaWystępowanie wyładowań elektrostatycznych prowadzi do powstawania bardzo dużych strat w produkcji lub serwisie w przypadku jego uszkodzenia. W niektórych przypadkach konieczne jest monitorowanie jego występowania w strefie (obszarze) chronionej. W artykule przedstawiono prowadzone prace nad systemem wykrywania wyładowań elektrostatycznych opartym o odbiór i analizę sygnału emisji elektromagnetycznej powstającego w momencie jego...
-
Surface Plasmon-Coupled Emission of Rhodamine 110 Aggregates in a Silica Nanolayer
PublikacjaFirst analysis of strong directional surface plasmon-coupled emission(SPCE) of ground-state formed intermolecular aggregates of Rhodamine 110 (R110) insilica nanofilms deposited on silver nanolayers is reported. Until now, the processes ofenergy transport and its trapping due to aggregate formation have not been studied in the presence of SPCE. A new approach to multicomponent systems with weakly and strongly fluorescent centers...
-
Spectroscopic and Wireless Sensor of Hematocrit Level
Publikacja -
Spectroscopic and wireless sensor of hematocrit level
PublikacjaAn optical method for hematocrit measurement has been presented. the sensor, designed and developed by authors, consists of spectroscopic set-up controlled by a microcontroller. measurement results are sent via wireless module. experiment has confirmed the ability of the sensor to determine the hematocrit with appropriate measurementaccuracy.
-
Remote Monitoring System for Impedance Spectroscopy using Wireless Sensor Network
PublikacjaThe architecture of a miniaturized impedanceanalyser with wireless communication module for remoteImpedance Spectroscopy (IS) of anticorrosion coatings ondifficult-to-reach objects (e.g. on the steel construction ofthe bridge) is described in this paper. Some practical aspectsof implementation of a Wireless Sensor Network (WSN) arealso discussed. A low scale, middle range, WSN networkcomposed of a Base Station (BS) with a Personal...
-
Quality testing methods of foil-based capacitors
PublikacjaKondensatory foliowe są powszechnie stosowanymi elementami pasywnymi w ukłądach zasilania. Dotychczasowe metody oceny ich jakości są długotrwałe oraz zużywają energię. W pracy przedstawiono propozycje szeregu nowych, bardziej efektywnych metod, które mogą być z sukcesem stosowane podczas ich produkcji.
-
Przenośny analizator impedancji z detektorem fazoczułym
PublikacjaW artykule przedstawiono prototyp analizatora impedancji, w którym zastosowano dwa mikrosystemy AD5933 do wydzielania składowych ortogonalnych sygnałów pomiarowych w zakresie częstotliwości od 0,01 Hz do 1 kHz i detektory fazoczułe dla częstotliwości z przedziału 1 kHz ÷ 100 kHz. Przyjęte rozwiązanie pozwoliło wyeliminować błędy pomiaru argumentu impedancji wprowadzane przez AD5933 w górnym zakresie częstotliwości. Uzyskany błąd...
-
Problems of varistor quality assessment during exploitation
PublikacjaVaristors are commonly used elements which protect power supply networks against high-voltage surges or lightning. Therefore, quality and endurance of these elements is important to avoid losses when an expensive laboratory equipment would not be protected from random overvoltages. Additionally, excessive leakage currents generate serious costs due to high energy consumption. The paper presents shortly properties of varistors that...
-
Plasma diagnostics of low pressure high power impulse magnetron sputtering assisted by electron cyclotron wave resonance plasma
Publikacja -
Non-destructive inspection of anti-corrosion protective coatings using optical coherent tomography
PublikacjaW artykule przedstawiono zastosowanie optycznej tomografii koherentnej (OCT) do badania antykorozyjnych powłok ochronnych. Omówiono właściwości optycznej interferometrii niskokoherentnej jako zastosowanej metody pomiarowej, opisano budowę pomiarowego systemu OCT, zbudowanego w Katedrze Metrologii i Optoelektroniki WETI PG. Przy pomocy zrealizowanego systemu przebadano grupę powierzchni metalicznych pokrytych różnymi powłokami antykorozyjnymi....
-
Mikro system zasilania bezprzewodowego
PublikacjaWzrastająca na rynku liczba układów mikrokontrolerów o bardzo niskiej konsumpcji energii elektrycznej umożliwia budowę układów zasilania bezprzewodowego, opartych o układy zbierające energię elektryczną z różnych źródeł występujących w naszym otoczeniu. Obecnie powstające układy wytwarzające energie elektryczną korzystają z jej konwersji m.in. z następujących źródeł: promieniowania słonecznego, energii drgań i wibracji, występujących...
-
Method and measurement system for DC characteristics measurement of power diodes in very wide current range
PublikacjaW artykule przedstawiono układ pomiarowy do pomiaru charakterystyk stałoprądowych diod. Pomiar przeprowadzany jest metodą impulsową w celu zapewnienia stałej temperatury badanego elementu w trakcie pomiaru. Do zapewnienia odpowiedniej liczby punktów pomiarowych wykorzystano układ zmodyfikowanej drabinki R2R z pojedynczymi kluczami sterującymi.
-
Low Current Transformer Utilizing Co-Based Amorphous Alloys
PublikacjaMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Investigation of Noise-Induced Instabilities in Quantitative BiologicalSpectroscopy and Its Implications for Noninvasive Glucose Monitoring
PublikacjaPrzedstawiono sposób oceny błędów jakie pojawiają się przy estymacji poziomu glukozy we krwi za pomocą pomiarów widm Ramana. Zastosowano nieliniowy algorytm regresji według maszyny wektorów nośnych. Określono jak na wyznaczenie stężenia glukozy we krwi wpływają błędy pomiarów widmach Ramana oraz błędów pomiaru referencyjnego stężenia glukozy podczas etapu kalibracji modelu (etapu uczenia algorytmu maszyny wektorów nośnych). Określono...
-
Improving AFM images with harmonic interference by spectral analysis
PublikacjaPrzedstawiono sposób usunięcia zakłóceń pojawiających się na obrazach uzyskiwanych z mikroskopu sił atomowych (AFM). Przybliżono kilka metod stosowanych do redukcji zakłóceń w obrazach. Następnie opisano zidentyfikowane zakłócenia harmoniczne oraz zaproponowany sposób ich znaczącej redukcji. W pracy zamieszczono szereg obrazów uzyskanych z mikroskopu AFM ilustrujących efekty powodowane zakłóceniami oraz skuteczność zaproponowanej...
-
Implementation of constant component filter in measurements of random telegraph signal noise
PublikacjaNoise is generated in all semiconductor devices. The intensity of these fluctuations depends on used elements, manufacturing process, operating conditions and device type. The result noise is a superposition of different kinds of fluctuations like thermal noise, generation-recombination noise, 1/f noise, shot noise and Random Telegraph Signal (RTS) noise. The last one, RTS noise is observed as nonstationary impulse fluctuations....
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublikacjaIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
Electrochemical oxidation of ionic liquids at highly boron doped diamond electrodes
PublikacjaUtlenianie elektrochemiczne przy zastosowaniu elektrod diamentowych wysoko domieszkowanych borem (BDD) było badane pod względem przydatności do utylizacji roztworów zawierających ciecze jonowe (ILs). Dwustronne elektrody Si/BDD przygotowano metodą chemicznego osadzania z fazy lotnej wspomaganego plazmą (MW PE CVD). Badanie przy użyciu skaningowej mikroskopii elektronowej (SEM) potwierdziło, że wytworzone warstwy były ciągłe i miały...