Determination of the ratio resistors in the input circuits of the NTC10k thermistor calibration system

Description

The presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.

The measurement system is shown in Fig. 1. A measurement system based on NI PXIe-1082Q (National Instruments Chassis), equipped with NI PXIe-8135 (Embedded Controller), NI PXIe-6341 (DAQ card) and NI SCB-68A (68-pin connector block), was used for the acquisition of measurement data. Eleven input channels of the DAQ card were used in the measurements. Channel 0 (ch_0) was used to measure the supply voltage. Sensors numbered 1 to 20 were tested in two parts, ten sensors per set. They were connected to the inputs of channels 1-10 (ch_1-ch_10) of the DAQ card.

The conditioning unit for individual sensors is shown in Fig.2. These circuits are performed on connector block SCB-68A as the voltage dividers. For the set of ten thermistors, the supply voltage is measured in channel 0 (ch_0) of the DAQ card, and individual thermistors are connected to channels 1-10 (ch_i).

Illustration of the publication

Fig. 1. The measurement setup

 

To make further calculations of the thermistor resistance and other parameters, we need to know the resistance values R in each measurement channel (from ch_1 to ch_10). The measurement results included in the data set 5001.zip, composed of ten files 5001kx.lvm (where: x is from 1 to 10) allows determining the R-value in each channel. They are obtained in the circuit, as shown in Figure 2, wherein the place of the thermistor in each of the measurement channels, a standard resistor with a resistance of 5001 Ohm was used.

Illustration of the publication

                                                                                                              Fig. 2. The sensor conditioning unit

Dataset file

5001.zip
11.2 kB, S3 ETag dba350f6fcd31c25433955a1504dfcf0-1, downloads: 24
The file hash is calculated from the formula
hexmd5(md5(part1)+md5(part2)+...)-{parts_count} where a single part of the file is 512 MB in size.

Example script for calculation:
https://github.com/antespi/s3md5
download file 5001.zip

File details

License:
Creative Commons: by 4.0 open in new tab
CC BY
Attribution
Raw data:
Data contained in dataset was not processed.

Details

Year of publication:
2021
Verification date:
2021-03-09
Creation date:
2021
Dataset language:
English
Fields of science:
  • Automation, electronic and electrical engineering (Engineering and Technology)
DOI:
DOI ID 10.34808/3gjm-h196 open in new tab
Series:
Verified by:
Gdańsk University of Technology

Keywords

References

Cite as

seen 80 times