ISSN:
Ministry points: Help
Year | Points | List |
---|---|---|
Year 2024 | 5 | Journal not listed on ministry scored journal list 2024 |
Year | Points | List |
---|---|---|
2024 | 5 | Journal not listed on ministry scored journal list 2024 |
2023 | 5 | Not listed on the ministry scored journals list 2023 |
2022 | 5 | Not listed on the ministry scored journals list (2019-2022) |
2021 | 5 | Not listed on the ministry scored journals list (2019-2022) |
2020 | 5 | Not listed on the ministry scored journals list (2019-2022) |
2019 | 5 | Not listed on the ministry scored journals list (2019-2022) |
2018 | 15 | Journals not listed on ministry scored list indexed in SCOPUS/Web of Science |
2017 | 15 | Journals not listed on ministry scored list indexed in SCOPUS/Web of Science |
2005 | 0 | archive |
2004 | 0 | archive |
2003 | 0 | archive |
2002 | 0 | archive |
2001 | 0 | archive |
2000 | 0 | archive |
1999 | 0 | archive |
1998 | 0 | archive |
1997 | 0 | archive |
1996 | 0 | archive |
1995 | 0 | archive |
1994 | 0 | archive |
Points CiteScore:
Year | Points |
---|---|
Year 2022 | 0.7 |
Year | Points |
---|---|
2022 | 0.7 |
2021 | 0.9 |
2020 | 0.8 |
2019 | 1 |
2018 | 1 |
2017 | 1 |
2016 | 1 |
2015 | 0.9 |
2014 | 0.9 |
2013 | 0.9 |
2012 | 0.9 |
2011 | 0.8 |
Impact Factor:
Sherpa Romeo:
Papers published in journal
Filters
total: 59
Catalog Journals
Year 2022
-
The electrical, morphological and optical properties of heavily boron-doped diamond sheets as a function of methane concentration in the gas phase
PublicationBoron-doped diamonds (BDD) are known for their excellent properties such as high thermal conductivity, high mobility, low absorption in visible light, and biocompatibility. In this work, we investigated the electrical, morphological and optical properties of heavily boron-doped diamond thin sheets as a function of methane concentration in the gas phase. Free-standing diamond sheets were fabricated using a microwave plasma-assisted...
Year 2021
-
Effects of laser pulse duration in two-photon vision threshold measurements
PublicationPulsed near-infrared (NIR) light sources can be successfully applied for both imaging and functional testing of the human eye, as published recently1. These two groups of applications have different requirements. For imaging applications, the most preferable is invisible scanning beam while efficiently visible stimulating beam is preferable for functional testing applications. The functional testing of human eye using NIR laser...
Year 2019
-
Solid state versus fiber picosecond infrared lasers applied to two-photon vision tests
PublicationDevelopment of new microperimetric tools dedicated for imaging of early functional changes in the retina may help in the monitoring of various ocular diseases progression e.g. Age-Related Macular Degeneration. Recently described two-photon vision may be applied to microperimetric devices. Many subjects with well-known disease history could be investigated with newly developed instrumentation that tests ability of human eye to perceive...
-
Selected properties and parameters of radio channel impulse response estimation in ISM 2.4 GHz band
PublicationThe article presents experimental research indicating that the impulse response of the communication channel, determined in practice, are not of an universal character, but only represent its approximate value for the frequency on which this measurement was made. Phases for each of the replicas of the measurement signal were determined during the analysis of the received signals in the baseband. Phase changes of individual replicas...
-
Polarization-dependent optical absorption in phosphorene flakes
PublicationThe interest of 2D materials is constantly increasing because of their very attractive mechanical, electrical and optical parameters. They have been used in many applications, e.g. photodetectors, sensors, modulators, insulators. One of the recently discovered 2D materials is phosphorene. In contrast to graphene, phosphorene has a direct bandgap tuned by numbers of layers in the 2D structure. The phosphorene flakes are strongly...
-
Influence of silver-core gold-shell nanoparticle parameters on the variation of surface-enhanced Raman spectra
PublicationThe detection of molecules by surface-enhanced Raman spectroscopy (SERS) is dependent on the nanomaterial used to induce the enhancement effect. This depends on a variety of parameters of the substrate such as the metal used for their creation, their shape, size and size distribution, concentration, as well as the parameters of the solution, such as packing of the nanoparticles, the complexity of the sample, the solvent, etc. It...
-
Adaptation of radar software to work with ambiguous distance measurement
PublicationA software extension for radar stations designed to work in the low-PRF mode that allows them to correctly measure range to targets outside of their instrumented range, is proposed. The solution does not require substantial modifications of the radar software. Additionally, we describe tools that allow one to simulate the output of a low-PRF radar observing targets that are outside its instrumented range. The proposed approach...
-
A concept of software extension of 3D low-PRF radar systems to 4D semi-medium-PRF radar systems
PublicationWe present a concept of software modification of three-dimensional (3D) radar systems, designed to work in the low pulse repetition frequency mode, that equips them with the ability to estimate the radial velocity and to properly measure the range of targets that are detected outside the radar’s instrumented range. Despite the fact that the proposed modifications are designed so as to require only minor changes in software, they...
Year 2018
-
Nitrogen-doped diamond thin films: potential application in Fabry-Pérot interferometer
PublicationIn this paper we present results of preliminary research of using nitrogen-doped diamond (NDD) films as reflective layer in Fabry-Pérot interferometer. NDD films were deposited on Si substrates by Microwave Plasma Enhanced Chemical Vapor Deposition (MPECVD) with the use of CH4, H2 and N2 gas mixtures. During deposition process methane flow rate varied while nitrogen flow was constant. We performed series of measurements which showed...
-
Model of optical phantoms thermal response upon irradiation with 975 nm dermatological laser
PublicationWe have developed a numerical model describing the optical and thermal behavior of optical tissue phantoms upon laser irradiation. According to our previous studies, the phantoms can be used as substitute of real skin from the optical, as well as thermal point of view. However, the thermal parameters are not entirely similar to those of real tissues thus there is a need to develop mathematical model, describing the thermal and...
Year 2017
-
Detection of immunological agent by optical fiber sensor: preliminary study
PublicationThe objective of this study is the application of optical methods for detection of immunological agent concentration. As the agent we used the Cyclaid, produced by Apotex Inc. In this article we investigated different Cyclaid concentrations in water. We used a Fabry-Pérot interferometer working in a reflective mode, the measurements were performed with source with central wavelength λ = 1550 nm. The preliminary investigation have...
Year 2006
-
Verification of multiband system for non-contact emissivity measurements
PublicationW pracy przeprowadzono weryfikację wielopasmowej pasywnej metody pomiaru emisyjności obiektu na drodze eksperymentalnej. W oparciu o zrealizowane stanowisko pomiarowe dokonano pomiarów emisyjności wybranych obiektów. Uzyskano dobrą zgodność wyników pomiarów z wynikami wcześniejszej komputerowej analizy systemu. Potwierdziło to przydatność wielopasmowej metody do pomiaru emisyjności w warunkach roboczych.
-
Synthesized light source for optical coherence tomography
PublicationW artykule omówiono wpływ parametrów źródła promieniowania optycznego na właściwości systemu OCT. Szczególną uwagę zwrócono na źródła syntezowane. Omówiono charakterystykę źródła zbudowanego z dwóch różnych diod SLD. Przedstawiono wyniki pomiarów, które wskazują na możliwości znacznego polepszenia czułości i rozdzielczości systemu OCT wykorzystującego takie źródło.
-
Setups for measurement of thermal time constant of bolometers and resistive layers
PublicationPrzedstawiono dwa układy do pomiaru termicznej stałej czasowejbolometrów i warstw rezystywnych, umożliwiające pomiar wartości tego parametru w zakresie od pojedynczych milisekund do kilku sekund. Przedstawiono wyniki pomiarów termicznej stałej czasowej wybranych warstw rezystywnych wykonanych w technologii LTCC z niestechiometrycznych tlenków lantanowo-strontowo-żelazowych oraz bolometru cienkowarstwowego wykonanego w tej samej...
-
Preparation and properties of nanoporius alumina-based humidity sensors
PublicationPrzedstawiono preparatykę czujników wilgotności na bazie nanoporowatego tlenku glinu. Wykorzystano spektroskopię impedancyjną do określenia właściwości czujników. Porównano właściwości czujników przygotowanych z różnymi parametrami procesu technologicznego.
-
Polarization state analysis in optical coherence tomography
PublicationW artykule zaprezentowano metody analizy stanu polaryzacji światła w systemach optycznej tomografii kohererentnej. Przedstawiono różne konfiguracje systemu PS-OCT wraz z ich parametrami oraz właściwościami. Omówiono zasadę pomiaru stanu polaryzacji ściatła przy użyciu systemu PS-OCT oraz przeprowadzono dyskusję nad przydatnością metody do badania struktury materiałów silnie rozpraszających promieniowanie.
-
Polarization sensitive optical coherence tomography system
PublicationW pracy pokazano system OCT czuły na stan polaryzacji do pomiaru właściwości dwójłomnych wybranych ośrodków rozpraszających światło. W systemie zastosowano detekcję zrównoważoną. Pokazano wstępne wyniki pomiarowe.
-
Optimization of working conditions of thick-film LSFO bolometers
PublicationPrzedstawiono opracowaną przez autorów metodę wytwarzania bolometrów w technologii LTCC. Jako warstwy aktywne wykorzystano niestechiometryczne tlenki lantanowo-strontowo żelazowe (LSFO). Przedstawiono wyniki pomiarów wybranych właściwości bolometrów oraz charakterystyki wykorzystane w procesie doboru punktu pracy bolometru.
-
Modeling of selected transducer designs for optical pressure sensors using polarization interferometry
PublicationW artykule przedstawiono wyniki modelowania metodą Elementów Skończonych wybranych konstrukcji membran do zastosowań w interferometrycznych czujnikach ciśnienia. Omówiono zależność prametrów membran od kształtu membrany, jej wymiarów i zastosowanego materiału. Zakres odkształcen badanych membran jest niezbyt duży, co może pogarszać dokładność pomiaru czujników ciśnienia, w których będą one stosowane Omówiono kierunki dalszych...
-
Modeling of polarimetric sensors using LabVIEW environment
PublicationW artykule przedstawiono program do modelowania światłowodowych sensorów polarymetrycznych. Program ten, stworzony w środowisku LabVIEW, wyznacza odpowiedź nieidealnego światłowodowego sensora polarymetrycznego na siłę działającą na przetwornik pomiarowy. Omówiono problemy występujące w procesie tworzenia oprogramowania do modelowania zjawisk fizycznych w graficznym środowisku programistycznym. Przedstawiono wybrane wyniki modelowania.
seen 1341 times