This article describes methods for safety integrity level (SIL) verification of safety-related functions with regard to probabilistic criteria given international standards IEC 61508 and IEC 61511. These functions are to be realized using the electrical, electronic and programmable electronic (E/E/PE) systems or safety instrumented systems (SIS). Some methods are proposed for quantitative probabilistic modelling taking into account potential dependent failures in redundant systems with divers channels within subsystems. The analyses of safety-related systems include testing and maintenance planning of subsystems, in particular the sensors and actuators with regard to the probabilistic criteria defined for given SIL. The methods are illustrated on some examples of systems from hazardous industry sector.

Cite as

Full text

full text is not available in portal

Keywords

Details

Category:
Articles
Type:
artykuły w czasopismach recenzowanych i innych wydawnictwach ciągłych
Published in:
Journal of Polish Safety and Reliability Association, Summer Safety and Reliability Seminars no. 3, pages 69 - 77,
ISSN: 2084-5316
Language:
Polish
Publication year:
2011
Bibliographic description:
Śliwiński M.: Integrity level verification for safety-related functions// Journal of Polish Safety and Reliability Association, Summer Safety and Reliability Seminars. -Vol. 3., (2011), s.69-77