Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors - Publication - Bridge of Knowledge

Search

Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors

Abstract

Fiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with thicknesses from 30 to 220 nm have been evaluated numerically and compared. TiO2 films were found to be the most promising candidates for the tuning of FPI reflectivity. In order to verify and illustrate the results of modelling, TiO2 films with the thickness of 80 nm have been deposited on the tip of a single-mode optical fiber by atomic layer deposition (ALD). The thickness, the structure, and the chemical properties of the films have been determined. The ability of the selected TiO2 films to modify the reflectivity of the Fabry-Pérot cavity, to provide protection of the fibers from aggressive environments, and to create multi-cavity interferometric sensors in FPI has then been studied. The presented sensor exhibits an ability to measure refractive index in the range close to that of silica glass fiber, where sensors without reflective films do not work, as was demonstrated by the measurement of the refractive index of benzene. This opens up the prospects of applying the investigated sensor in biosensing, which we confirmed by measuring the refractive index of hemoglobin and glucose.

Cite as

Full text

download paper
downloaded 54 times
Publication version
Accepted or Published Version
License
Creative Commons: CC-BY open in new tab

Keywords

Details

Category:
Monographic publication
Type:
rozdział, artykuł w książce - dziele zbiorowym /podręczniku w języku o zasięgu międzynarodowym
Language:
English
Publication year:
2019
Bibliographic description:
Hirsch M., Majchrowicz D., Wierzba P., Weber M., Bechelany M., Szczerska M.: Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors// Optical methods in Sensing and Imaging for medical and Biological Applications/ : , 2019, s.28-49
Sources of funding:
  • Statutory activity/subsidy
Verified by:
Gdańsk University of Technology

seen 98 times

Recommended for you

Meta Tags