Physical and mathematical modelling of implant-fascia system in order to improve laparoscopic repair of ventral hernia - Publication - Bridge of Knowledge

Search

Physical and mathematical modelling of implant-fascia system in order to improve laparoscopic repair of ventral hernia

Abstract

This paper describes an investigation of biomechanical behaviour of hernia repair, which is focused on the selection of safe linking of certain type of implant with fascia in laparoscopic operation. The strength of various fixations of the implant to the fascia is analysed. Methods: The research is based on experimental observations of operated hernia model behaviour during a dynamic impulse load corresponding to post-operative cough. Fifty seven different types of models of implanted mesh are considered. Five types of implants and five types of connectors are used. Mechanical properties of the implants as well as limit tearing forces of joints are identified in uni-axial tensile tests. Mathematical model of implanted mesh based on finite element method is proposed. The identified mechanical properties of the materials are applied and the model is calibrated using quantities measured during experiments. Findings: The presented results point at trans-abdominal sutures and ProTacks (connectors) and at DynaMesh (implant) as the most reliable materials used in ventral hernia operation, in the tested materials group. Desired properties of implants seemto be: elastic properties similar to the properties of tissues and high local strength, as fixation have a local character. The proposedmathematicalmodel can be applied to simulate real behaviour of an implant with appropriate accuracy and to estimate the number of tacks for the implantation of hernia meshes. Interpretation: The presented resultsmay help in the deeper understanding of the fascia–mesh systembehaviour, and thus may lead to improve the fixation methods.

Citations

  • 2 4

    CrossRef

  • 0

    Web of Science

  • 2 8

    Scopus

Cite as

Full text

full text is not available in portal

Keywords

Details

Category:
Articles
Type:
artykuł w czasopiśmie wyróżnionym w JCR
Published in:
CLINICAL BIOMECHANICS no. 28, pages 743 - 751,
ISSN: 0268-0033
Language:
English
Publication year:
2013
Bibliographic description:
Tomaszewska A., Lubowiecka I., Szymczak C., Lubowiecka I., Śmietański M., Meronk B., Kłosowski P., Bury k.: Physical and mathematical modelling of implant-fascia system in order to improve laparoscopic repair of ventral hernia// CLINICAL BIOMECHANICS. -Vol. 28, nr. 7 (2013), s.743-751
DOI:
Digital Object Identifier (open in new tab) 10.1016/j.clinbiomech.2013.06.009