Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard
Abstract
The scope of the paper is to propose a method for determining the size of shear caps in a slab–column-connections-reinforced concrete structure. Usually, shear heads are used to enhance slab–column connection, especially when the transverse reinforcement does not give the required punching shear load capacity. The dimensions of the shear head should provide the punching shear resistance of the connection inside and outside the enhanced region. The process of selecting the size of the shear head is iterative. The parametric analysis of the ACI 318 code and EC2 standard has the objective of indicating which control perimeter (inside or outside the shear head) has a decisive impact on the punching shear capacity of the connection. Based on the analysis, the authors propose methods for selecting the dimensions of the shear head with practical application examples. The paper is intended to provide scientists, civil engineers, and designers with guidelines to design the process of the slab–column connections with the shear caps.
Citations
-
2
CrossRef
-
0
Web of Science
-
3
Scopus
Authors (2)
Cite as
Full text
- Publication version
- Accepted or Published Version
- License
- open in new tab
Keywords
Details
- Category:
- Articles
- Type:
- artykuły w czasopismach
- Published in:
-
Materials
no. 13,
ISSN: 1996-1944 - Language:
- English
- Publication year:
- 2020
- Bibliographic description:
- Grabski M., Ambroziak A.: Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard// Materials -Vol. 13,iss. 21 (2020), s.4938-
- DOI:
- Digital Object Identifier (open in new tab) 10.3390/ma13214938
- Verified by:
- Gdańsk University of Technology
seen 138 times
Recommended for you
Load introduction to composite columns revisited—Significance of force allocation and shear connection stiffness
- B. Grzeszykowski,
- M. Lewandowski-Szewczyk,
- M. Niedośpiał