Study of the NO2 sensing mechanism of PEDOT-RGO film using in situ Raman Spectroscopy - Publication - Bridge of Knowledge

Search

Study of the NO2 sensing mechanism of PEDOT-RGO film using in situ Raman Spectroscopy

Abstract

In this work, the mechanism of the NO2 reaction with PEDOT-RGO composite film has been investigated via in situ Raman spectroscopy. Reduced graphene oxide (RGO), poly(3,4-ethylenedioxytiophene)-reduced graphene oxide (PEDOT-RGO) and poly(3,4-ethylenedioxytiophene)/ClO4− (PEDOT/ClO4−) films were fabricated using an electrodeposition method and used as resistance sensors of gaseous nitrogen dioxide. The experimental results indicate that NO2 causes overoxidation of the PEDOT polymer (PEDOT/ClO4− film) which leads to resistance increase and irreversible response. In contrast, the PEDOT-RGO response in the presence of NO2 is reversible. During short NO2 exposure, PEDOT from the PEDOT-RGO composite does not react to the gas but the presence of RGO in the PEDOT-RGO composite does not affect the overoxidation potential. It was found that the nitrogen dioxide reacts more readily to reduced graphene oxide, thus RGO “protects” the polymer against the adverse overoxidation process.

Citations

  • 2 8

    CrossRef

  • 0

    Web of Science

  • 3 0

    Scopus

Cite as

Full text

full text is not available in portal

Keywords

Details

Category:
Articles
Type:
artykuł w czasopiśmie wyróżnionym w JCR
Published in:
SENSORS AND ACTUATORS B-CHEMICAL no. 260, pages 1025 - 1033,
ISSN: 0925-4005
Language:
English
Publication year:
2018
Bibliographic description:
Dunst K., Trzciński K., Scheibe B., Sawczak M., Jasiński P.: Study of the NO2 sensing mechanism of PEDOT-RGO film using in situ Raman Spectroscopy// SENSORS AND ACTUATORS B-CHEMICAL. -Vol. 260, (2018), s.1025-1033
DOI:
Digital Object Identifier (open in new tab) 10.1016/j.snb.2018.01.089
Verified by:
Gdańsk University of Technology

seen 186 times

Recommended for you