Janusz Podliński
Employment
Publications
Filters
total: 16
Catalog Publications
Year 2012
-
comparison of circular and rectangular narrow esps with longitudinal wire electrode
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of...
-
EHD Flow Measured by 2D PIV in a Narrow Electrostatic Precipitator with Longitudinal Wire Electrode
PublicationIn this paper, results of the electrohydrodynamic (EHD) flow patterns in two narrow ESPs with longitudinally-to-flow wire electrode arepresented. The influence of the ESP geometry on the EHD flow generated in the ESP was investigated. The results obtained from 2-dimensional(2D) Particle Image Velocimetry (PIV) showed similarities and differences of the particle flow in the wire-plate and wire-cylinder type ESP.
-
Electrohydrodynamic Secondary Flow and Particle Collection Efficiency in Spike-Plate Multi-Electrode Electrostatic Precipitator
PublicationIn this work the results of electrohydrodynamic (EHD) secondary flowmeasurements in a spike-plate type electrostatic precipitator (ESP) are presented. In the investigated ESP two-sided and one-sided spike electrodes were used as a discharge electrodes. The results of 2D PIVmeasurements showed that flow pattern obtained for a different spike tips positions in respect to the primary flow direction significantly changing the flow...
-
Electrohydrodynamic secondary flow in the electrostatic precipitator with spiked electrodes
PublicationIn this work, the results of electrohydrodynamic (EHD) secondary flow measurements in an electrostatic precipitator (ESP) with one-sidedspike electrodes are presented. The EHD secondary flow was measured for one-sided spike electrodes with the spike tips directed either upstream or downstream the primary flow. The results showed different flow patterns for different spike tips direction in respect to the primary flow direction....
-
Investigation of Narrow Electrostatic Precipitator with Wire Multi-Electrode
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are notenough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of interest...
-
Investigation of Narrow Transverse and Longitudinal Electrostatic Precipitators
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of...
-
Multi-DBD actuator with floating interelectrode for aerodynamic control
PublicationIn this paper the use of a floating inter-electrode in a multi-DBD (dielectric barrier discharge) plasma actuator is described. The multi-DBD plasma actuators with floating inter-electrodes were investigated to get a longer DBD on a dielectric surface and to maximise generated net airflow. Our actuator was used to control the boundary layer flow separation around NACA0012 airfoil model. The results of our investigations suggests...
-
Multi-DBD plasma actuator for flow separation control around NACA 0012 and NACA 0015 airfoil models
PublicationIn this paper application of innovative multi-DBD plasma actuator for flow separation control is presented. The influence of the airflowgenerated by this actuator on the flow around NACA 0012 and NACA 0015 airfoil models was investigated. The results obtained from 2D PIVmeasurements showed that the multi-DBD actuator with floating interelectrode can be attractive for leading and trailing edge separation control.
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublicationIn this paper the electrohydrodynamic (EHD)device for gas pumping and cleaning is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device. The current-voltage characteristics were measured and the corona discharge...
Year 2011
-
Collection Efficiency in Narrow Electrostatic Precipitators with a Longitudinal or Transverse Wire Electrode
PublicationRecently narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application in diesel engine exhaust systems. In this work, results of particle collection efficiency measurements in narrow electrostatic precipitators for negative and positive dc voltage polarity are presented. The ESP usedin this work was a parallelepiped equipped with wire discharge electrode and two collecting plate-electrodes....
-
EHD Flow Measured by 2D PIV in a Narrow Electrostatic Precipitator with Longitudinally-to-flow Wire Electrode
PublicationIn this paper, results of the electrohydrodynamic (EHD) flow patterns in two narrow ESPs with longitudinally-to-flow wire electrode are presented. The influence of the ESP geometry on the EHD flow generated in the ESP was investigated. The results obtained from 2 dimensional (2D) Particle Image Velocimetry (PIV) showed similarities and differences of the particle flow in the wire-plate and wire-cylinder type ESP.
-
Electrohydrodynamic Secondary Flow and Particle Collection Efficiency in a One-sided Spike-plate Type Electrostatic Precipitator
PublicationIn this work, results of electrohydrodynamic secondary flow and particle collection efficiency measurements in an electrostatic precipitator under positive and negative voltage polarity are presented. The electrostatic precipitator had two plate collecting electrodes and a single spike discharge electrode. The spike tips were only on one side of the discharge electrode, therefore called a one-sided spike electrode. The electrohydrodynamic...
Year 2010
-
Collection efficiency in narrow electrostatic precipitators with a longitudinal or transverse wire electrode
Publication -
Electrohydrodynamic flow and particle collection efficiency in a one-sided spike-plate type electrostatic precipitator
Publication -
Electrohydrodynamic Flow Patterns in a Narrow Electrostatic Precipitator with Longitudinal Wire Electrode for Various Electrode Geometries
PublicationRecently narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application in diesel engines. In this paper results of 2-dimensional (2D) Particle Image Velocimetry (PIV) measurements of the flow patterns in a narrow ESP for a various electrode geometries are presented. The PIV measurements were carried out in the observation plane that is perpendicular to the ESP duct. The ESP was...
-
Laser Investigations of Flow Patterns in Electrostatic Precipitators and Non Thermal Plasma Reactors
Publication
seen 627 times