Determination of flow properties of a serial connection of a pressure relief valve (C=6.2, b=0.38) and a silencer (C=1.4) from changes in air pressure in a tank being emptied - Open Research Data - Bridge of Knowledge

Search

Determination of flow properties of a serial connection of a pressure relief valve (C=6.2, b=0.38) and a silencer (C=1.4) from changes in air pressure in a tank being emptied

Description

The aim of the study was to determine the flow properties of serial connection of pneumatic components.
The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source -> S -> being filled tank, (3) being emptied tank -> PRV -> S -> ambient atmosphere. So, three data files are included in the dataset. Each data file has a header where parameters of experiment are given. Additionally, for the elements analised, catalogue flow properties are given by means of sonic conductance and critical pressure ratio. The given data allow to verify calculation procedures for determination of flow properties of pneumatic components arranged in-line.

Dataset file

INLINE_PRV3_S5.ZIP
92.3 kB, S3 ETag 0cb7b97e0bc59883ae71ecddf3d1a1f8-1, downloads: 40
The file hash is calculated from the formula
hexmd5(md5(part1)+md5(part2)+...)-{parts_count} where a single part of the file is 512 MB in size.

Example script for calculation:
https://github.com/antespi/s3md5
download file INLINE_PRV3_S5.ZIP

File details

License:
Creative Commons: by 4.0 open in new tab
CC BY
Attribution

Details

Year of publication:
2021
Verification date:
2021-07-23
Dataset language:
English
Fields of science:
  • mechanical engineering (Engineering and Technology)
DOI:
DOI ID 10.34808/t68r-6g43 open in new tab
Series:
Verified by:
Gdańsk University of Technology

Keywords

Cite as

seen 83 times