Description
Dataset contains results of low frequency noise observation during discharge of commercially available supercapacitor, type DRL 2.7V 10F, with a nominal capacitance 10 F and a nominal voltage 2.7 V. Supercapacitor was charged to various voltages and discharged through a resistor. In the experiment the 50 Ohm and 200 Ohm resistors were used. The supercapacitor was charged to various voltages from 0,5 V to 2,7 V, which is nominal voltage of this device. The measurement method and measurement setup are described in https://doi.org/10.1515/mms-2017-0059.
Data is stored in binary files with little-endian byte order (8 bytes per sample, double precision). Single .bin file contains 32 seconds of voltage observation taken with sampling frequency 1024 Hz. Files contain observations for single experiment are stored in one ZIP archive and numbered sequentially. The electrical signal was amplified before sampled. Signal amplification for each experiment is given in "description.txt" file.
Filename decoding:
D4_RRROhm_VVV_NNN.bin
RRR - discharge resistor value in Ohms (50/200), VVV - charging voltage (0V5 -> 0,5 V; 1V0 -> 1,0 V, ...), NNN - sequential file number.
The binary data have to be read as little-endian byte order double precision number.
Dataset file
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
where a single part of the file is 512 MB in size.Example script for calculation:
https://github.com/antespi/s3md5
File details
- License:
-
open in new tabCC BYAttribution
- Raw data:
- Data contained in dataset was not processed.
Details
- Year of publication:
- 2021
- Verification date:
- 2021-03-29
- Dataset language:
- English
- Fields of science:
-
- Automation, electronic and electrical engineering (Engineering and Technology)
- DOI:
- DOI ID 10.34808/7v5s-vx82 open in new tab
- Funding:
- Verified by:
- Gdańsk University of Technology
Keywords
References
- publication MEASUREMENT OF NOISE IN SUPERCAPACITORS
Cite as
Authors
seen 140 times