Results of EIS measuremnts and DRT analysis of SrTi0.30Fe0.70O3-d oxygen electrode at 800 °C and 1% oxygen partial pressure by using three R-CPE fiting elements
Description
This dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 800 °C and 1% of oxygen partial pressure. EIS and DRT spectra of simmulated three R-CPE elements from equivalent circuit, are also included. Results converted to electrode surfaces area and dived by two electrodes. For DRT analysis freely available DRTTool from the prof. Ciucci group was utilised. All measured EIS spectra were corrected for inductance prior to DRT analysis.
Dataset file
EIS_and_DRT_3xRCPE_results_for_STF70_T800_at_800C_1_pO2.xlsx
48.5 kB,
S3 ETag
88151dcaa6e27d4bd40efe8a27dd2d7c-1,
downloads: 64
The file hash is calculated from the formula
Example script for calculation:
https://github.com/antespi/s3md5
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
where a single part of the file is 512 MB in size.Example script for calculation:
https://github.com/antespi/s3md5
File details
- License:
-
open in new tabCC BY-NCNon-commercial
Details
- Year of publication:
- 2021
- Verification date:
- 2021-07-21
- Dataset language:
- English
- Fields of science:
-
- Automation, electronic and electrical engineering (Engineering and Technology)
- materials engineering (Engineering and Technology)
- DOI:
- DOI ID 10.34808/evc9-g551 open in new tab
- Funding:
- Series:
- Verified by:
- Gdańsk University of Technology
Keywords
References
Cite as
Authors
seen 164 times