Description
The dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of the analyzer as well as to limit measurement time. In this dataset, the DC polarisation was set to 0 V and AC amplitude was 1 V. The dataset presents results acquired after 2 hours of exposition. The 3% NaCl solution was used as an electrolyte.
Top-left figure presents impedance modulus and top-right figure presents impedance angle for the top cell presented in bottom-left figure.
Dataset file
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
where a single part of the file is 512 MB in size.Example script for calculation:
https://github.com/antespi/s3md5
File details
- License:
-
open in new tabCC BY-NCNon-commercial
Details
- Year of publication:
- 2021
- Verification date:
- 2021-04-29
- Dataset language:
- English
- Fields of science:
-
- Automation, electronic and electrical engineering (Engineering and Technology)
- DOI:
- DOI ID 10.34808/dty8-3m72 open in new tab
- Series:
- Verified by:
- Gdańsk University of Technology
Keywords
Cite as
Authors
seen 118 times