On power stream in motor or drive system
PublicationIn a motor or in a drive system the quantity of power increases in the direction opposite to the direction of power flow. Energy losses and energy efficiency of a motor or a drive system must be presented as functions of physical quantities independent of losses. Such quantities are speed and load. But the picture of power stream in a motor or in a drive system is presented in the literature in the form of traditional Sankey...
-
Losses and energy efficiency of drive motors and systems
PublicationLosses and energy efficiency of every drive motor must be presented as functions of physical quantities independent of losses in the motor. Such quantities are speed and load required by the machine or device driven by the motor, changing in the drive operating field. Speed and load of the motor decide of the instantaneous useful power of the motor and also in a differentiated way of kinds and values of losses occurring in the...
-
Losses and energy efficiency of drive motors and systems
PublicationLosses and energy efficiency of every drive motor must be presented as functions of physical quantities independent of losses in the motor. Such quantities are speed and load required by the machine or device driven by the motor, changing in the drive operating field. Speed and load of the motor decide of the instantaneous useful power of the motor and also in a differentiated way of kinds and values of losses occurring in the...
-
Energy losses in hydrostatic drive:Drive investigation method compatible with diagram of power increase opposite to the direction of power flow
PublicationEnergy losses and efficiency of drive motor must be presented as functions of physical quantities independent of losses in the motor. Such quantities are speed and load required by the driven device, changing in the drive operating field. Speed and load decide of the useful power and, in differentiated way, of kinds and values of losses in the motor. But energy losses and efficiency of drive motors are evaluated as functions of...
-
O strumieniu mocy w silniku lub w układzie napędowym
PublicationW silniku lub w układzie napędowym wielkość strumienia mocy rośnie w kierunku przeciwnym do kierunku przepływu mocy. Straty energetyczne i sprawność energetyczna silnika lub układu napędowego powinny być przedstawiane jako funkcje wielkości fizycznych niezależnych od strat. Takimi wielkościami są prędkość i obciążenie silnika. Jednakże obraz strumienia mocy w silniku lub w układzie napędowym jest przedstawiany w literaturze w formie...
-
Driving a new perspective Professor Zygmunt Paszota, faculty of ocean engineering and ship technology, Gdansk University of Technology, Poland, explains a new approach to the Sankey Diagram for drive motors
PublicationThe paper presents the necessity of replacing the traditional, commonly accepted but erroneous, Sankey diagram of power decrease in the direction of power flow by the diagram, proposed by the Author, of power increase in the direction opposite to the direction of power flow. The proposed view of losses and energy efficiency should be applied to all types of drive motors and drive systems. The presented proposals open a new perspective...
-
Współczynniki strat energetycznych w elementach napędu hydrostatycznego
PublicationW każdym układzie napędowym należy zastąpić obraz przepływu mocy opisany dotychczas powszechnie stosowanym wykresem Sankey’a spadku mocy zgodnego z kierunkiem przepływu mocy proponowanym przez autora wykresem wzrostu mocy w układzie przeciwnego do kierunku przepływu mocy. Należy więc opisywać straty i sprawność energetyczną a także pole pracy każdego silnika i układu napędowego jako zależne od wielkości fizycznych niezależnych...
-
Method of sum of power losses as a way for determining the ki coefficients of energy losses in hydraulic motor
PublicationThis paper shows application of the method of sum of power losses to determining energy losses which occur in hydraulic rotary motor in situation when not all laboratory data are at one’s disposal or when no use is made of data contained in catalogue charts. The method makes it possible to determine the coefficients ,ki , of energy losses occurring in the motor. The method of sum of power losses is based on the approach proposed...
-
Energy losses in the hydraulic rotational motor - definitions and relations for evaluation of the efficiency of motor and hydrostatic drive
PublicationStosowane dotychczas w badaniach naukowych i w praktyce przemysłowej metody oceny strat i sprawności energetycznej obrotowych silników hydraulicznych stosowanych w napędach hydrostatycznych dają błędne rezultaty, ponieważ obarczone są wpływem samych strat na parametry, w funkcji których straty i sprawności są oceniane.Celem pracy było zdefiniowanie w silniku parametrów pracy, rozwijanych mocy, występujących strat i sprawności energetycznej...
-
Five-phase induction motor drive with sine-wave filter
PublicationThe paper presents closed loop ac drive with 5 phase induction motor operating with voltage source inverter and sine wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed co ntrol can be applied. In the presence of output filter both control and estimation algorithms should be modified due to sine wave filter installation....