displaying 1000 best results Help
Search results for: ALLERGY TO IMPLANT COMPONENTS
-
Wilms tumor - Male, 11 - Tissue image [5210730031828861]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031821141]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031822081]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031824291]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031826241]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031827511]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031823601]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [521073003182701]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031825701]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031827961]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=2.10, b=0.14) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=2.00, b=0.11) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=2.80, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=2.00, b=0.11) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=6.40, b=0.45) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=2.10, b=0.14) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=2.10, b=0.14) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=6.40, b=0.45) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=5.50, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=3.30, b=0.40) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=5.50, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=6.20, b=0.38) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=5.50, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...