Recent progress in experimental studies of electrohydrodynamic flow in electrostatic precipitators
PublicationMany experimental, theoretical and numerical works were devoted to the electrohydrodynamic (EHD) flow generated in electrostatic precipitators (EPSs). The generally accepted conclusion from these studies is that the EHD flow plays an important role in the particle collection in ESPs. However, despite of the recent fast progress in numerical simulation and experimental techniques used in the ESPs studies many problems related to...
-
Electrohydrodynamic flow patterns and collection efficiency in narrow wire-cylinder type electrostatic precipitator
PublicationRecently, narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application for the cleaning of the exhaust gases emitted by diesel engines. Diesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. Therefore,...
-
Evolution of electrohydrodynamic flow of sduspended particles in a needle-to-plate negative DC corona discharge in air
PublicationCorona discharges are used for collecting dust in electrostatic precipitators (ESPs). The dust collection is mainlyrealized by the electric forces which move the ionized dust particles to the collecting electrodes. However, the presence of coronadischarge in the space between the charging and collecting electrodes in ESPs causes also the so-called ionic wind which set the gasmolecules and dust...
-
Electrohydrodynamic Flow Patterns in a Narrow Electrostatic Precipitator with Longitudinal Wire Electrode for Various Electrode Geometries
PublicationRecently narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application in diesel engines. In this paper results of 2-dimensional (2D) Particle Image Velocimetry (PIV) measurements of the flow patterns in a narrow ESP for a various electrode geometries are presented. The PIV measurements were carried out in the observation plane that is perpendicular to the ESP duct. The ESP was...
-
Electrohydrodynamic flow and particle collection efficiency in a one-sided spike-plate type electrostatic precipitator
Publication -
Electrohydrodynamic secondary flow in the electrostatic precipitator with spiked electrodes
PublicationIn this work, the results of electrohydrodynamic (EHD) secondary flow measurements in an electrostatic precipitator (ESP) with one-sidedspike electrodes are presented. The EHD secondary flow was measured for one-sided spike electrodes with the spike tips directed either upstream or downstream the primary flow. The results showed different flow patterns for different spike tips direction in respect to the primary flow direction....
-
Electrohydrodynamic Secondary Flow and Particle Collection Efficiency in Spike-Plate Multi-Electrode Electrostatic Precipitator
PublicationIn this work the results of electrohydrodynamic (EHD) secondary flowmeasurements in a spike-plate type electrostatic precipitator (ESP) are presented. In the investigated ESP two-sided and one-sided spike electrodes were used as a discharge electrodes. The results of 2D PIVmeasurements showed that flow pattern obtained for a different spike tips positions in respect to the primary flow direction significantly changing the flow...
-
Electrohydrodynamic secondary flow and particle collection efficiency in spike-plate multi-electrode electrostatic precipitator
PublicationIn this work the results of electrohydrodynamic (EHD) secondary flow measurements in a spike-plate type electrostatic precipitator (ESP) are presented. In the investigated ESP two-sided and one-sided spike electrodes were used as a discharge electrodes. The results of 2D PIV measurements showed that flow pattern obtained for a different spike tips positions in respect to the primary flow direction significantly changing the flow...
-
Electrohydrodynamic Secondary Flow and Particle Collection Efficiency in a One-sided Spike-plate Type Electrostatic Precipitator
PublicationIn this work, results of electrohydrodynamic secondary flow and particle collection efficiency measurements in an electrostatic precipitator under positive and negative voltage polarity are presented. The electrostatic precipitator had two plate collecting electrodes and a single spike discharge electrode. The spike tips were only on one side of the discharge electrode, therefore called a one-sided spike electrode. The electrohydrodynamic...
-
EHD Flow Measured by 2D PIV in a Narrow Electrostatic Precipitator with Longitudinally-to-flow Wire Electrode
PublicationIn this paper, results of the electrohydrodynamic (EHD) flow patterns in two narrow ESPs with longitudinally-to-flow wire electrode are presented. The influence of the ESP geometry on the EHD flow generated in the ESP was investigated. The results obtained from 2 dimensional (2D) Particle Image Velocimetry (PIV) showed similarities and differences of the particle flow in the wire-plate and wire-cylinder type ESP.
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublicationIn this paper the electrohydrodynamic (EHD)device for gas pumping and cleaning is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device. The current-voltage characteristics were measured and the corona discharge...
-
EHD Flow Measured by 2D PIV in a Narrow Electrostatic Precipitator with Longitudinal Wire Electrode
PublicationIn this paper, results of the electrohydrodynamic (EHD) flow patterns in two narrow ESPs with longitudinally-to-flow wire electrode arepresented. The influence of the ESP geometry on the EHD flow generated in the ESP was investigated. The results obtained from 2-dimensional(2D) Particle Image Velocimetry (PIV) showed similarities and differences of the particle flow in the wire-plate and wire-cylinder type ESP.
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublicationIn this paper the pumping effect of air in the electrohydrodynamic (EHD) device for dust particle collection is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. The asymmetric electric field and generated discharge resulted in a unidirectional airflow through the EHD device. The current-voltage characteristics...
-
Comparison of EHD devices with parallel and in series spiked electrodes
PublicationIn this paper two electrohydrodynamic (EHD) devices for gas pumping and cleaning are presented. In both cases to induce an airflow in these EHD devices corona discharge was used. The discharge was generated between the spiked electrodes set parallel (the first case) or in series (the second case) and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device....
-
comparison of circular and rectangular narrow esps with longitudinal wire electrode
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of...
-
Pumping effect measured by PIV method in multi-layer spike electrode EHD device for air cleaning
PublicationDust particles can be harmful for human health when inhaled. Especially dangerous are submicron dust particles, which can contain traces of toxic elements and can easily penetrate into human respiratory system. Thus, new devices for air cleaning are needed. In this work the flow velocity field patterns measured by Particle Image Velocimetry (PIV) method in an electrohydrodynamic (EHD) device for air cleaning are presented. The...
-
Mikropompa elektrohydrodynamiczna na ciecz dielektryczną zasilana napięciem stałym
PublicationW niniejszym artykule zaprezentowano projekt i działanie miniaturowej pompy elektrohydrodynamicznej (EHD) zasilanej napięciem stałym przeznaczonej do chłodzenia elementów elektronicznych. Zmierzono natężenie przepływu cieczy oraz ciśnienie wytwarzane przez pracującą mikropompę. Maksymalne natężenie przepływu, 0,5 ml/min, uzyskano dla napięcia 12 kV. Zmierzone ciśnienie wyniosło 500 Pa przy przyłożonym napięciu 6 kV. Maksymalny...
-
CO2 capture using steam ejector condenser under electro hydrodynamic actuator with non-condensable gas and cyclone separator: A numerical study
PublicationThe concept for condensation of steam and CO2 separation in a negative CO2 emission gas power plant involves the utilization of a steam ejector condenser (SEC) for direct-contact condensation of vapor with inert gas (CO2) on a spray of subcooled liquid, integrated with a separator to produce pure CO2. Due to the increasing diffusion resistance and reduced convective heat transfer between the steam and subcooled water phases...
-
Electric Field-Driven Assembly of Sulfonated Polystyrene Microspheres
PublicationA designed assembly of particles at liquid interfaces offers many advantages for development of materials, and can be performed by various means. Electric fields provide a flexible method for structuring particles on drops, utilizing electrohydrodynamic circulation flows, and dielectrophoretic and electrophoretic interactions. In addition to the properties of the applied electric field, the manipulation of particles often depends...
-
Investigation of Narrow Electrostatic Precipitator with Wire Multi-Electrode
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are notenough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of interest...
-
Fully Separated Flow Control Using DBD Plasma Actuators Located at the Leading Edge of an Airfoil
PublicationIn the framework of the PLASMAERO European project, experiments were conducted to investigate the authority of surface DBD plasma actuators to alter a fully separated flow around an airfoil in order to improve its aerodynamic performances in its natural stall regime. In this paper, unsteady excitation control is more specifically investigated. The key control parameter studied here is the burst frequency which periodically imposes...
-
Surface Dielectric Barrier Discharge Plasma Actuators
PublicationThis paper presents a part of the works conducted in the Plasmaero European project (task 1.1) on surface dielectric barrier discharge actuators applied to airflow control. The study is divided into several parts. In the first part, the goal is to enhance the electric wind produced by a typical single DBD actuator by optimization of the active electrode shape. For instance, the use of a thin wire instead of a plate air-exposed...
-
Trailing-Edge Separation Control of a NACA 0015 Airfoil Using Dielectric-Barrier-Discharge Plasma Actuators
PublicationThis paper presents a part of the works conducted in the Plasmaero European project (task 3.1), where the trailing-edge flow separation of a NACA 0015 airfoil has been controlled using four different dielectric barrier discharge (DBD) actuator types at three institutions across Europe. The results show that it is possible to enhance the aerodynamic performance of aircraft at speeds up to 40 m/s. Dielectric-barrier-discharge vortex...