Search results for: drinking water distribution system
-
Hierarchical model predictive control of integrated quality and quantity in drinking water distribution systems
PublicationW artykule zaproponowane zostało zintegrowane podejście do sterowania ilością i jakością w systemach zaopatrzenia i dystrybucji wody. Sterowanie zintegrowane polega na optymalizowaniu kosztów operacyjnych zaspokajając zapotrzebowanie na wodę o wymaganej jakości i spełniając ograniczenia systemu. To zagadnienie sterowania optymalizującego jest zagadnieniem złożonym z powodu nieliniowości, dużego wymiaru, ograniczeń na wyjście, występowania...
-
Identification of the Contamination Source Location in the Drinking Water Distribution System Based on the Neural Network Classifier
PublicationThe contamination ingression to the Water Distribution System (WDS) may have a major impact on the drinking water consumers health. In the case of the WDS contamination the data from the water quality sensors may be efficiently used for the appropriate disaster management. In this paper the methodology based on the Learning Vector Quantization (LVQ) neural network classifier for the identification of the contamination source location...
-
Optimised Allocation of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublicationA problem of optimised placement of the hard quality sensors in Drinking Water Distribution Systems for robust quality monitoring is formulated. Two numerical algorithms to solve the problem are derived. The optimality is meant as achieving a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm. The robust estimation algorithm recently developed...
-
Two Time-Scale Hierarchical Control of Integrated Quantity and Quality in Drinking Water Distribution Systems
PublicationThe paper considers a feedback optimising control of drinking water distribution systems (DWDS). Although the optimised pump and valves scheduling and disinfectant injection control attracted considerable attention over last two decades most of the contributions were limited to an open-loop optimisation repetitively performed during the DWDS operation. Also, while a strong interaction between the water quantity and quality exists...
-
Optimizing control by robustly feasible model predictive control and application to drinking water distribution systems
PublicationThe paper considers optimizing Model Predictive Control (MPC) for nonlinear plants with output constraints under uncertainties. Although the MPC technology can handle the constraints in the model by solving constraint model based optimization task, satisfying the plant output constraints under the model uncertainty still remains a challenge. The paper proposes Robustly Feasible MPC (RFMPC), which achieves feasibility of the outputs...
-
Optimizing Control by Robustly Feasible Model Predictive Control and Application to Drinking Water Distribution Systems
PublicationThe paper considers optimizing Model Predictive Control (MPC) for nonlinear plants with output constraints under uncertainties. Although the MPC technology can handle the constraints in the model by solving constraint model based optimization task, satisfying the plant output constraints still remains a challenge. The paper proposes Robustly Feasible MPC (RFMPC), which achieves feasibility of the outputs in the controlled plant....
-
An optimised placement of the hard quality sensors for a robust monitoring of the chlorine concentration in drinking water distribution systems
PublicationThe problem of an optimised placement of the hard quality sensors in drinking water distribution systemsunder several water demand scenarios for a robust monitoring of the chlorine concentration is formulatedin this paper. The optimality is understood as achieving a desired trade off between the sensors and theirmaintenance costs and the accuracy of estimation of the chlorine concentration. The contribution of thiswork is a comprehensive...
-
Optimised Robust Placement of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublicationA problem of optimised robust placement of the hard quality sensors in Drinking Water Distribution Systems under several water demand scenarios for robust quality monitoring is formulated. Numerical algorithms to solve the problem are derived. The optimality is meant as achieving at the same time a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm...
-
Genetic solver of optimization task of mpc for optimizing control of integrated quantity and quality in drinking water distribution systems
PublicationPredykcyjne sterowanie zintegrowana jakością i ilością wody pitnej umożliwia uzyskanie lepszej jakości sterowania niż w przypadku innych metod. Niestety wymaga rozwiązania nieliniowego, niewypukłego problemu optymalizacji. Z tego względu potrzebne jest wykorzystanie specjalizowanego solwera w celu rozwiązania problemu optymalizacji predykcyjnej w wymaganych czasie. W tym artykule przedstawiony jest dedykowany algorytm genetyczny...
-
Interval estimator for chlorine monitoring in drinking water distribution systems under uncertain system dynamics, inputs and state measurement errors
PublicationThe design of interval observer for estimation of unmeasured state variables for application to drinking water distribution systems is described in this paper. In particular, it considers the design of such observer for estimation of water quality described by free chlorine concentration. An interval observer is derived to produce robust interval bounds on the estimated water quality state variables. The stability and robustness...