Filters
total: 6470
filtered: 652
-
Catalog
- Publications 4040 available results
- Journals 123 available results
- Conferences 10 available results
- Publishing Houses 83 available results
- People 226 available results
- Inventions 7 available results
- Projects 53 available results
- Laboratories 2 available results
- Research Teams 2 available results
- e-Learning Courses 646 available results
- Events 91 available results
- Open Research Data 1187 available results
Chosen catalog filters
Search results for: Heritage BIM
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=6.20, b=0.38) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=5.50, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=5.50, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two directional control valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first DCV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=6.40, b=0.45) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.70, b=0.32) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=2.80, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.70, b=0.32) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=2.00, b=0.11) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=5.50, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=7.30, b=0.49) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=5.50, b=0.37) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=2.40, b=026.) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=5.30, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV ->...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=2.10, b=0.14) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.70, b=0.32) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.40, b=0.26) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV ->...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.80, b=0.25) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV ->...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
The database of localization and expression of classical aquaporins (AQPs) in the male reproductive system in cattle
Open Research DataThe data present research results being part of the OPUS-22 project entitled “In search of new markers of male fertility in cattle. Aquaporins expression in the reproductive organs and sperm of the bulls (Bos taurus)” financed by the National Science Center in Poland (grant no. 2021/43/B/NZ9/00204). The aim of this part of the project was (i) to determine...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.00, b=0.11) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV ->...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV ->...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=6.20, b=0.38) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.70, b=0.32) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV ->...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=5.70, b=0.32) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=2.80, b=0.25) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.50, b=0.37) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=5.30, b=0.38) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=2.00, b=0.11) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a parallel connection of two pneumatic elements with (C=4.40, b=0.42) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of parallel connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in parallel. Three test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being...