dr inż. Krzysztof Dobrzyński
Employment
- Assistant Professor at Department of Electrical Power Engineering
Publications
Filters
total: 109
Catalog Publications
Year 2023
-
Estimation of Synchronous Generator and AVR Parameters Based on Gradient and Genetic Methods
PublicationThe author present a method for the estimation of selected synchronous generator model and AVR parameters using a gradient and a genetic algorithm. The paper shows an example of model parameter estimation for a turbogenerator, based on the generator voltage time responses obtained during an active and reactive power rejection test
-
Management of MV/LV Transformer Replacement Based on AMI Platform
PublicationThe paper presents the extended possibilities of managing the selection and replacement of MV/LV transformers using the measurement data from the Advanced Metering Infrastructure (AMI) system. The analysis was conducted on samples of over 1900 transformers that operate in two different types of MV grids: rural and urban. The analysis has shown that there is a great potential in the field of optimizing the rated power of the transformers.
Year 2020
-
Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines
PublicationCable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublicationLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
Year 2019
-
Cross-Bonding of MV Cable Lines for Energy Losses Decrease
PublicationCurrently, almost all medium voltage cable lines (MV) operate with the return wires earthed at both ends of the cable. Such a way of operation causes that during normal states of operation as well as during disturbances, e.g. short-circuits, in the return wires induce currents whose values mainly depend on the currents flowing in the phase wires. These currents in normal operating states are a source of additional energy losses...
-
Energy losses reduction in the medium voltage cable line – case study
PublicationThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
Modelling of MV and HV Cable Lines
PublicationOverhead and cable lines are fundamental elements of power systems. Participation of cable lines is smaller and their percentage decreases as voltage is increased. HV cable lines are often built with the use of cables which are composed of coaxial metallic sheaths. Such cables are also often used in MV networks. The sheath may operate in different confgurations. In the case of Polish MV network the sheaths are earthed at both ends....
-
Obliczanie prądów w przewodach odgromowych w linii napowietrzno-kablowej
PublicationW referacie analizowana jest linia napowietrzno-kablowa 110 kV. Referat prezentuje wpływ sposobu uziemiania żył powrotnych kabla WN na wartości prądów przy zwarciach jednofazowych, ze szczególnym uwzględnieniem prądów płynących w przewodach odgromowych linii napowietrznej. Wykazano, że dobór przewodów odgromowych linii napowietrznej powinien uwzględniać nie tylko parametry odcinka linii kablowej, ale także sposób uziemienia żył...
-
Uproszczone modelowanie linii kablowych wysokiego napięcia a napięcia indukowane w żyłach powrotnych – studium przypadku
PublicationLinie kablowe, obok linii napowietrznych, są jednym z podstawowych elementów składowych systemów elektroenergetycznych. Stosowane są głównie na terenach zurbanizowanych, gdzie prowadzenie linii napowietrznych jest mocno utrudnione lub wręcz niemożliwe. Linie kablowe wysokiego napięcia budowane są głównie z wykorzystaniem kabli, które oprócz żyły roboczej mają również współosiową żyłę powrotną. Istnieje kilka układów pracy takich...
-
Voltage control in a power system with renewable sources of energy
PublicationIntensive development of distributed generation in power systems, caused by the European Union energy policy, gives possibility for improving safety in power delivery as well as optimizing the costs of the systems functioning. In this context, distributed generation can be used for voltage control in power systems – it can be performed by the control of reactive power of each source of energy or a group of energy sources. This...
-
Wpływ wirtualnej inercji na system elektroenergetyczny
PublicationW referacie omówiono problem wpływu ubytku inercji naturalnej na stabilność częstotliwościową systemu elektroenergetycznego oraz ideę wirtualnej inercji. Przedstawiono struktury komercyjnych układów wirtualnej inercji. Zaprezentowano przykład wpływu układu wirtualnej inercji na właściwości dynamiczne systemu elektroenergetycznego.
-
Wykorzystanie logiki rozmytej do regulacji napięcia w systemie elektroenergetycznym z wybranymi odnawialnymi źródłami energii
PublicationW ostatnich latach w krajowym systemie elektroenergetycznym liczba i moc odnawialnych źródeł energii znacząco wzrosły. Źródła te można wykorzystać nie tylko do produkcji tzw. czystej energii elektrycznej, ale również do poprawy warunków napięciowych w tym systemie. W artykule przedstawiono koncepcję układu regulacji napięcia w systemie elektroenergetycznym z przyłączonymi w pewnym obszarze: farmą wiatrową, farmą fotowoltaiczną,...
Year 2018
-
Cross-border transmission line configuration influence on the electrical power and energy billing process
PublicationIn 2015 a connection between the Polish and Lithuanian power systems become fully operational. The connection consists of a 400 kV double circuit transmission line and a back-to-back HVDC substation located on the Lithuanian side. A magnetic couplings between the circuits of the transmission line cause that during power transmission a different values of active power losses are observed in both circuits. This situation may cause...
-
Delivery of Ancillary Services in Distribution Power Systems
PublicationOne of the technical and organizational challenges the power system faces in deregulated market conditions is to organize an ancillary services market. The growing share of distributed generation of variable (intermittent) energy sources and a change in the market position of consumers, causes the demand for distributed delivery of ancillary services. For this purpose, it is sought to use the ability of the regulatory measures:...
-
Wirtualna inercja w systemie elektroenergetycznym
PublicationW referacie omówiono problem wpływu ubytku inercji naturalnej na stabilność częstotliwościową systemu elektroenergetycznego oraz ideę wirtualnej inercji. Przedstawiono struktury komercyjnych układów wirtualnej inercji. Zaprezentowano przykład wpływu układu wirtualnej inercji na właściwości dynamiczne systemu elektroenergetycznego.
Year 2017
-
Analiza napięć indukowanych i strat mocy w kablach elektroenergetycznych wysokiego napięcia dla wybranych sposobów uziemienia żył powrotnych
PublicationDostarczanie mocy do centrów miast coraz częściej odbywa się z wykorzystaniem linii kablowych o napięciu 110 kV. To dogodny sposób zasilania, a praktycznie jedyny możliwy w przypadku gęstej zabudowy miejskiej. Kable wysokiego napięcia zawierają współosiową żyłę powrotną, w której podczas normalnej pracy oraz w stanach zakłóceniowych (podczas zwarć) mogą indukować się znaczne napięcia względem ziemi, co zagraża porażeniem i/lub...
-
Analiza napięć indukowanych w żyłach powrotnych kabli wysokiego napięcia dla ich wybranych konfiguracji
PublicationW żyłach powrotnych kabli wysokiego napięcia mogą indukować się znaczne napięcia względem ziemi przy przepływie prądów roboczych oraz prądów zwarciowych, co zagraża porażeniem i/lub uszkodzeniem zewnętrznej powłoki kabla. Wartości tych napięć zależą od sposobu ułożenia i długości kabli, sposobu uziemienia ich żył powrotnych, wartości prądu w żyłach roboczych, a także transpozycji żył roboczych i powrotnych. W artykule przedstawiono...
-
Analiza napięć indukowanych w żyłach powrotnych kabli wysokiego napięcia w wybranych konfiguracjach ich ułożenia
PublicationW żyłach powrotnych kabli wysokiego napięcia mogą indukować się znaczne napięcia względem ziemi przy przepływie prądów roboczych oraz prądów zwarciowych, co zagraża porażeniem i/lub uszkodzeniem zewnętrznej powłoki kabla. Wartości tych napięć zależą od sposobu ułożenia i długości kabli, sposobu uziemienia ich żył powrotnych, wartości prądu w żyłach roboczych, a także transpozycji żył roboczych i powrotnych. W artykule przedstawiono...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Harmonics produced by traction substations – computer modelling and experimental verification
PublicationVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...
-
Identification of the customer meter assignment to phases in LV grid: Selected issues of UPGRID project realization
PublicationThe paper presents selected issues on the European UPGRID grant implemented by a consortium of companies from seven European states, including from Poland, on the monitoring and control of low voltage grid using measurement pre-registered data by smart AMI meters. The paper focuses on the issue of lack of information on the assignment of communal meters to individual phases.
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Low-frequency tripping characteristics of residual current devices
PublicationFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublicationPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...
-
Neutral earthing reactor protection
PublicationThe IEEE and CIGRE recommend protection systems for high voltage shunt reactors. Unfortunately the recommendations do not include guidelines for the protection of neutral earthing reactors, which are often connected to shunt reactors to increase the effectiveness of single pole auto-reclosing. The paper discusses earthing reactor protection issues with particular emphasis on the detection of internal faults. An analysis carried...
-
Problemy pracy zabezpieczeń odległościowych linii 400 kV w Polsce północno-wschodniej
PublicationPrzedstawiono analizę wpływu połączenia polskiego systemu elektroenergetycznego z systemem Litwy na detekcję zakłóceń przez zabezpieczenia odległościowe linii 400 kV znajdujących się w najbliższym otoczeniu stacji Ełk Bis.
-
Projekt UPGRID
PublicationMiędzynarodowy projekt UPGRID realizowany jest w ramach programu Horyzont 2020 (H2020). Program ten to największy jak dotąd program Unii Europejskiej (UE) w zakresie badań naukowych i innowacji. W projekcie UPGRID uczestniczy 17 partnerów z 9 krajów EU. Głównym celem projektu UPGRID jest rozwój funkcjonalności, które służą integracji sieci nn oraz SN ze stroną konsumencką. W ramach projektu wybrane technologie Inteligentnych Sieci...
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublicationThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.
-
Resonance problems in UHV transmission lines
PublicationThe paper presents resonance phenomena observed in 400 kV transmission lines in the Polish power system. Two events are analysed, when shunt reactors used for reactive power compensation, caused overvoltages and overcurrent protection tripping as a result of resonance. An oscillographic fault recordings from protection devices are compared to time domain simulation results. The obtained simulation results match fault recordings,...
-
The impact of the distribution network reconfiguration on active power losses: Selected issues of UPGRID project realization
PublicationThe dynamic development of smart grids allows the use of remote controllable switches to change the configuration of the distribution network. The paper discusses the impact of the distribution system reconfiguration on active power losses, taking into account the typical daily load profiles. Based on modified IEEE 33-bus test distribution system the article presents the method of selection the appropriate sensitivity factor and...
-
Use of AMI Meters in the Process of Low Voltage Grid Optimization
PublicationThis is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .
-
Wybrane problemy detekcji zakłóceń w dławiku uziemiającym przyłączonym do punktu gwiazdowego dławika kompensacyjnego
PublicationW referacie przedstawiono problematykę zabezpieczania dławików uziemiających przyłączanych do punktu gwiazdowego dławików kompensacyjnych stosowanych w liniach wysokiego napięcia, ze szczególnym uwzględnieniem detekcji zwarć wewnętrznych. Przedstawiono analizy modelowe dla rzeczywistego układu oddanego do pracy w 2015, który docelowo ma zostać doposażony w dławiki uziemiające.
-
Wykorzystanie infrastruktury systemu ami w monitorowaniu i sterowaniu sieciami niskiego napięcia
PublicationW referacie przedstawiono wybrane zagadnienia z prac prowadzonych w ramach europejskiego grantu UPGRID realizowanego przez konsorcjum firm z siedmiu państw europejskich, w tym również z Polski, który dotyczy między innymi optymalizacji pracy sieci niskiego napięcia przy wykorzystaniu danych z liczników AMI.
-
Wykorzystanie liczników AMI w procesie optymalizacji pracy sieci niskiego napięcia
PublicationPrezentowany jest opis projektu dotyczącego m.in. optymalizacji pracy sieci niskiego napięcia przy wykorzystaniu danych z liczników AMI. Prace były prowadzone w ramach europejskiego grantu UPGRID, realizowanego przez konsorcjum firm z siedmiu państw europejskich, w tym również z Polski.
-
Zabezpieczanie dławika uziemiającego przyłączonego do punktu gwiazdowego dławika kompensacyjnego wysokiego napięcia
PublicationW artykule przedstawiono problematykę zabezpieczania dławików uziemiających przyłączanych do punktu gwiazdowego dławików kompensacyjnych stosowanych w liniach wysokiego napięcia, ze szczególnym uwzględnieniem detekcji zwarć wewnętrznych. Załączono analizy modelowe dla rzeczywistego układu oddanego do pracy w 2015 roku, który docelowo ma zostać doposażony w dławiki uziemiające.
-
Zjawiska rezonansowe a praca zabezpieczeń nadprądowych dławików kompensacyjnych linii wysokiego napięcia
PublicationW referacie prezentowany jest opis działania zabezpieczeń nadprądowych dławików kompensacyjnych zainstalowanych w linii Ełk Bis – Alytus, jakie miało miejsce w grudniu 2015 r. W efekcie działania zabezpieczeń nastąpiło zbędne wyłączenie dwóch dławików. Referat wyjaśnia przyczyny zaistniałej sytuacji prezentując analizę matematyczną, wyniki symulacji komputerowej oraz dane z rejestratorów zakłóceń.
Year 2016
-
Calculations of Short-Circuit Current Flows in Earth Wires of HV Lines
PublicationThis paper presents a method which enables calculating flows of short-circuit currents in earth wires of high voltage transmission lines, and its implementation in the form of a computer programme. The algorithm enables performing calculations for a double-fed line and starconnected lines (three terminal lines). The developed programme enables verifying dimensioning of earth wires in the context of their short-circuit thermal withstand...
-
Computer-aided analysis of resonance risk in power system with Static Var Compensators
PublicationStatic Var Compensators operation in a power system may significantly improve voltage profiles in nodes and the reactive power balance, as well as ensure greater system stability in emergency conditions. However these devices may be a cause of a resonance in the system. The aim of this paper is to call attention to the need to include resonance phenomena in a compensator’s location evaluation process. The analysis performed in...
-
Higher harmonics produced by traction substations – computer modelling and experimental verification
PublicationVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers, although the rms value of load current does not exceed their current-carrying capacity. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublicationIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Issues of Estimating the Maximum Distributed Generation at High Wind Power Participation
PublicationThis paper presents the methods of estimating the maximum power that can be connected to the power system in distributed generation sources. Wind turbine generator systems (WTGS) were selected as the subject for analysis. Nonetheless, the considerations presented in this paper are only general and also apply to other types of power sources, including the sources that are not considered part of distributed generation.
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublicationThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Power and energy measurement problems in transmission line between Poland-Lithuania
PublicationThe paper discusses problem of power and energy metering in double circuit overhead transmission line. Considerations are based on example of transmission line connecting Polish substation Bis Elk and Lithuanian substation Alytus.
-
Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids
PublicationThis paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.
-
Problemy pomiarów mocy i energii w linii elektroenergetycznej Polska-Litwa
PublicationW referacie przedstawiono zagadnienia związane z pomiarem mocy i energii w linii dwutorowej. Rozważania oparto na linii łączącej stacje elektroenergetyczne Ełk Bis i Alytus.
-
Problemy pracy zabezpieczeń odległościowych linii 400 kV w Polsce północno-wschodniej
PublicationW roku 2015 oddano do użytku połączenie polskiego systemu elektroenergetycznego z systemem elektroenergetycznym Litwy. Połączenie to zrealizowano z wykorzystaniem dwutorowej linii napowietrznej 400 kV Ełk Bis – Alytus oraz łącza back-to-back (BtB). W artykule przeanalizowano wpływ realizacji nowego połączenia, a tym samym zmianę konfiguracji sieci 400 kV, na detekcję zakłóceń przez zabezpieczenia odległościowe linii 400 kV znajdujących...
-
Simplified Distribution Grid Modelling for Connection Analyses
PublicationThis paper considers the modelling of medium and low voltage grids for the purpose of connection studies by distribution grid operators. Possible simplifications in grid modelling are discussed, which are acceptable from the viewpoint of the final result. The main driver of the modelling simplification is the MS Excel environment used as the computation platform, and the limitation of time for grid modelling.
-
The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid
PublicationThis paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered...
-
Zjawiska rezonansowe a praca zabezpieczeń nadprądowych dławików kompensacyjnych linii wysokiego napięcia
PublicationZaprezentowano opis działania zabezpieczeń nadprądowych dławików kompensacyjnych zainstalowanych w linii Ełk Bis - Alytus, jakie miało miejsce w grudniu 2015 r. W efekcie działania zabezpieczeń nastąpiło zbędne wyłączenie dwóch dławików. Referat wyjaśnia przyczyny zaistniałej sytuacji prezentując analizę matematyczną, wyniki symulacji komputerowej oraz dane z rejestratorów zakłóceń.
Year 2015
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Effectiveness of the robust PSS design
PublicationThe paper discusses optimal PSS of synchronous generator synthesis. The optimal controller is an Hinf controller, what means that minimises Hinf norm of transfer function between the exogenous signals such as reference inputs and disturbances, and the error signals which are to be minimised to meet the control objective. The dynamic properties of the plant are shaped by choosing appropriate weighting function applied to the plant...
-
EHV transmission lines wires location on line operation issues - case studies
PublicationTransmission lines towers construction affects the line parameters and influences on its operation in the future. Misguided design of the tower can lead to serious problems such as overvoltages, electric arc extinction difficulties, voltage asymmetry, resonance phenomena or increasing of magnetic field near the line. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors....
-
Induced sheath voltages in 110 kV power cables – case study
PublicationThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Influence of Shunt Compensation with SVC Devices on Resonance Risk in Power Systems
PublicationMany analyses are required to locate a new reactive power source in a power system. The choice of a location is a very complex matter which requires various aspects to be considered. Selecting a location also entails the necessity to assess it from the point of view of the selected compensator’s structure as well as the system’s performance in various states with the new device on. The paper presents the issues of assessing compensator...
-
Metoda analizy wielokryterialnej do planowania rozwoju sieci elektroenergetycznej średniego i niskiego napięcia
PublicationW artykule przedstawiono metodę wspomagającą decyzje w zakresie wyboru wariantu przyłączenia odbioru do sieci elektroenergetycznej dystrybucyjnej niskiego napięcia lub średniego napięcia oraz mikrogeneracji do sieci niskiego napięcia. Metodę tą zaimplementowano w skoroszycie kalkulacyjnym Microsoft Excel i zastosowano do analizy złożonych przypadków przyłączenia odbioru lub mikrogeneracji.
-
Metoda analizy wielokryterialnej wyboru wariantu przyłączenia do sieci elektroenergetycznej dystrybucyjnej niskiego i średniego napięcia
PublicationW artykule przedstawiono metodę wspomagającą decyzje w zakresie wyboru najlepszego wariantu przyłączenia odbioru do sieci elektroenergetycznej dystrybucyjnej niskiego napięcia lub średniego napięcia oraz mikrogeneracji do sieci niskiego napięcia. Metoda bazuje na poszukiwaniu wariantu o najniższej wartości miernika oceny syntetycznej, który jest średnią ważoną mierników ocen cząstkowych, wyznaczanych z zastosowaniem ośmiu przyjętych...
-
Nonlinear secondary arc model use for evaluation of single pole auto-reclosing effectiveness
PublicationPurpose – The purpose of this paper is to discuss two evaluation methods of single pole autoreclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc implementation is presented. Design/methodology/approach – A computer simulation studies were...
-
Obliczanie rozpływu prądów zwarciowych w przewodach odgromowych linii WN
PublicationW referacie przedstawiono metodę oraz jej implementację w postaci programu komputerowego, które umożliwiają obliczenie rozpływu prądów zwarciowych w linkach odgromowych linii wysokiego napięcia. Algorytm umożliwia obliczenia dla linii dwustronne zasilanej oraz linii w układzie gwiazdowym (z odczepem). Opracowany program umożliwia weryfikację doboru przewodów odgromowych z punktu widzenia wytrzymałości zwarciowej cieplnej.
-
Obliczenia rozpływu prądów zwarciowych w przewodach odgromowych linii WN
PublicationW artykule przedstawiono metodę oraz jej implementację w postaci programu komputerowego, które umożliwiają obliczenie rozpływu prądów zwarciowych w linkach odgromowych linii wysokiego napięcia. Algorytm umożliwia obliczenia dla linii dwustronnie zasilanej oraz linii w układzie gwiazdowym (z odczepem). Opracowany program umożliwia weryfikację doboru przewodów odgromowych z punktu widzenia wytrzymałości zwarciowej cieplnej.
-
Problematyka doboru zabezpieczeń dławików kompensacyjnych pracujących w sieciach najwyższych napięć
PublicationW artykule przedstawiono trudności, jakie napotyka się podczas projektowania systemu zabezpieczeń dla dławików przyłączanych bezpośrednio do sieci najwyższych napięć (NN). Bazując na przykładzie budowanej aktualnie stacji 400 kV Ełk Bis, pokazano, że możliwości zabezpieczenia dławika, oparte na układach EAZ wykorzystujących pomiary sygnałów elektrycznych z przekładników prądowych i napięciowych, mają swoje ograniczenia i w pewnych...
-
Problematyka kompensacji mocy biernej linii elektroenergetycznych wysokiego napięcia
PublicationW artykule przedstawiono rozważania dotyczące doboru dławików kompensacyjnych dla linii elektroenergetycznej dwutorowej wysokiego napięcia 400 kV, na przykładzie nowo budowanej linii Ełk Bis – Alytus. W analizach uwzględniono różne stany pracy układu. Zamieszczone wyniki dotyczą poziomów napięć w stanach ustalonych, podczas procesów łączeniowych oraz zwarć.
-
Projektowanie i efektywność stabilizatora systemowego minimalizującego normę Hinf.
PublicationArtykuł opisuje możliwości syntezy krzepkiego stabilizatora systemowego minimalizującego normę Hinf, którego właściwości dynamiczne kształtowane są przez wybór odpowiedniej funkcji wagowej. Rozważana jest efektywność metody w procesie projektowania stabilizatora systemowego.
-
Secondary arc modelling for single pole reclosing analyses
PublicationThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage calculation results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc model implementation is presented. The paper presents the study results for the three types of EHV transmission...
-
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
PublicationThis paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
-
Uproszczone modelowanie sieci dystrybucyjnej na potrzeby analiz przyłączeniowych
PublicationW artykule przedstawiono rozważania na temat sposobu modelowania sieci średniego (SN) i niskiego (nn) napięcia na potrzeby wykonywania analiz przyłączeniowych przez operatorów sieci dystrybucyjnej. Przeprowadzono dyskusję na temat możliwych do wykonania uproszczeń w modelowaniu sieci, które są do zaakceptowania z punktu widzenia uzyskiwanego wyniku końcowego. Głównym elementem wymuszającym uproszenia w modelowaniu jest środowisko...
-
Uproszone modelowanie sieci dystrybucyjnej na potrzeby analiz przyłączeniowych
PublicationW artykule przedstawiono rozważania na temat sposobu modelowania sieci średniego (SN) i niskiego (nn) napięcia na potrzeby wykonywania analiz przyłączeniowych przez operatorów sieci dystrybucyjnej. Przeprowadzono dyskusję na temat możliwych do wykonania uproszczeń w modelowaniu sieci, które są do zaakceptowania z punktu widzenia uzyskiwanego wyniku końcowego. Głównym elementem wymuszającym uproszenia w modelowaniu jest środowisko...
-
Wybrane problemy doboru zabezpieczeń dławików kompensacyjnych pracujących w sieciach najwyższych napięć
PublicationW referacie przedstawiono trudności jakie napotyka się podczas projektowania systemu zabezpieczeń dla dławików przyłączanych bezpośrednio do sieci najwyższych napięć (NN). Referat, bazując na przykładzie budowanej aktualnie stacji 400 kV Ełk Bis, pokazuje, że możliwości zabezpieczenia dławika, oparte na układach EAZ wykorzystujących pomiary sygnałów elektrycznych z przekładników prądowych i napięciowych mają swoje ograniczenia...
-
Wybrane problemy kompensacji mocy biernej linii elektroenergetycznej wysokiego napięcia
PublicationW artykule przedstawiono rozważania dotyczące doboru dławików kompensacyjnych dla linii elektroenergetycznej dwutorowej wysokiego napięcia 400 kV, na przykładzie nowobudowanej linii Ełk Bis-Alytus . W analizach uwzględniono różne stany pracy układu. Zamieszczone wyniki dotyczą poziomów napięć w stanach ustalonych, podczas procesów łączeniowych oraz zwarć.
Year 2014
-
Badanie działania sterownika telemechaniki z funkcją sygnalizatora zwarć w wykorzystaniem modelu referencyjnego sieci SN
PublicationPrzedmiotem opracowania jest analiza działania sterownika telemechaniki STGP-3 z funkcją sygnalizatora zwarć opracowanego przez Instytut Energetyki Oddział Gdańsk. Badania sterownika przeprowadzono w laboratorium Elektroenergetycznej Automatyki Zabezpieczeniowej Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej.
-
Calculation of Induced Sheath Voltages in Power Cables – Single Circuit System versus Double Circuit System
PublicationThis paper presents comparison of values of induced sheath voltages in power cable metallic sheaths when one or two cables per phase are used. Calculation of voltages is performed for various phase sequences of the power cables. Three types of the sheaths bonding and earthing are considered. Shock hazard and voltage stress of non-metallic outer sheath of cables are evaluated. The proposed, optimal configuration of the power cable...
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublicationMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Detection of high frequency current components by residual current devices
PublicationThe negative impact of current harmonics on the main components of residual current devices is presented. A solution for the improvement of the operation of residual current devices is proposed.
-
Estimation of Selected Synchronous Generator Parameters Based on the Gradient Method
PublicationThe authors present a method for the estimation of synchronous generator model parameters using a gradient algorithm. The paper shows an example of model parameter estimation for a turbogenerator and hydrogenerator, based on the generator voltage time responses obtained during an active and reactive power rejection test.
-
Evaluation Of Single Pole Auto-Reclosing Effectiveness With Nonlinear Secondary Arc Model
PublicationThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a non-linear secondary arc implementation is presented. The authors indicate, that precise representation of secondary electric arc leads to more...
-
Induced Sheath Voltages In 110 Kv Power Cables – Case Study
PublicationThe paper considers shock hazard due to induced sheath voltages in 110 kV power cables. Various configurations of the metallic sheaths bonding and earthing (single-point bonding, both-ends bonding, cross-bonding) are analysed. Taking into account shock hazard and ability of the system to power transfer an optimal configuration is proposed.
-
Proposition of the steam turbine governor structure modification
PublicationThere is considered the steam turbine governor operation during defense and restoration of the power system. It points out weaknesses of currently used governor structures. The new controller is proposed, that takes advantages of those curently used. The new controller allows for more effective control of the turbine in emergency situations, at frequencies much different from the nominal value.
-
Szacowanie maksymalnej mocy generacji rozproszonej w systemie elektroenergetycznym
PublicationW monografii przedstawiono metodykę szacowania maksymalnej mocy zainstalowanej, tzw. generacji rozproszonej. Metodyka ta umożliwia określenie wartości maksymalnej mocy możliwej do przyłączenia w danym miejscu (miejscach) systemu elektroenergetycznego w źródłach generacji rozproszonej, a ponadto pozwala na ocenę wariantów przyłączenia. W metodyce wykorzystuje się funkcję celu, która uwzględnia wymagania wobec źródeł energii elektrycznej...
-
Zastosowanie gramianów w automatyce APKO
PublicationPrzedstawiono zastosowanie gramianów do oceny zapasu stabilności systemu elektroenergetycznego. Zaproponowano układ regulacji turbiny w postaci Automatyki Przeciw-Kołysaniowo Odciążającej (APKO) do ochrony turbozespołu wytwórczego przed utratą stabilności.
Year 2013
-
Estymacja wybranych parametrów modelu generatora synchronicznego z wykorzystaniem metody gradientowej rozmytej – referat konferencyjny
PublicationReferat prezentuje metodę estymacji parametrów modelu generatora synchronicznego z wykorzystaniem algorytmu gradientowego. Przedstawiono przykład estymacji parametrów modelu hydrogeneratora w oparciu o przebiegi napięcia generatora podczas dwóch testów: zrzutu mocy czynnej i zrzutu mocy biernej. Prezentowane analizy zostały wykonane w autorskim programie wykorzystującym środowisko modelowania PowerFactory firmy DIgSILENT.
-
Interior Point Method Evaluation for Reactive Power Flow Optimization in the Power System
PublicationThe paper verifies the performance of an interior point method in reactive power flow optimization in the power system. The study was conducted on a 28 node CIGRE system, using the interior point method optimization procedures implemented in Power Factory software.
-
Koncepcja przyłączenia elektrowni fotowoltaicznej na terenie działki nr 43 obręb 2 Nowy Staw do istniejącej sieci
PublicationW Pracy przedstawiono wstępną koncepcję przyłączenia elektrowni fotowoltaicznej do sieci średniego napięcia na terenie gminy Nowy Staw.
-
Ocena możliwości wykorzystania metody punktu wewnętrznego do optymalizacji rozpływu mocy biernej w systemie elektroenergetycznym – referat konferencyjny.
PublicationW referacie poddano weryfikacji metodę punktu wewnętrznego pod kątem jej wykorzystania do optymalizacji rozpływu mocy biernej w systemie elektroenergetycznym. Rozważania przeprowadzono na 28 węzłowym systemie CIGRE, z wykorzystaniem zaimplementowanej metody punktu wewnętrznego w programie PowerFactory firmy DIgSILENT.
-
Optymalizacja poziomów napięć i rozpływów mocy biernej w systemie elektroenergetycznym z wykorzystaniem logiki rozmytej – referat konferencyjny
PublicationReferat prezentuje zagadnienia związane ze sterowaniem poziomami napięć w systemie elektroenergetycznym. Rozważana jest autorska metody optymalizacji rozpływu mocy biernej, prowadząca do poprawy warunków napięciowych w systemie elektroenergetycznym i ograniczenia strat mocy czynnej. Opracowana metoda optymalizacyjna bazuje na procedurze opartej o logikę rozmytą, wspomaganej algorytmem gradientowym. Metoda została zaimplementowana...
-
Start-up of a power unit of a thermal power plant auxiliary systems with supply from a hydropower plant
PublicationThis article discusses the issues related to a power unit of a thermal power plant start-up with the use of a hydropower plant. Hydropower plant can supply and will enable start-up of auxiliary equipment in a power unit of a thermal power plant. Due to high capacity of auxiliary drives, start-up of auxiliaries in a thermal power plant after blackout (and boiler shutdown) is not possible from emergency energy sources in the power...
-
Voltage and Reactive Power Load Flow Optimization in the Power System Using Fuzzy Logic
PublicationThe paper presents issues related to voltage control in the power system. An original method of reactive power flow optimization is considered, which leads to improved voltages in the power system and reduced active power losses. The optimization method is based on a procedure that employs fuzzy logic and is supported by a gradient search algorithm. The method has been implemented in PLANS software and verified.
Year 2012
-
Metodyka szacowania maksymalnej generacji rozproszonej ulokowanej w elektrowniach wiatrowych
PublicationPraca przedstawia metodykę szacowania maksymalnej mocy zainstalowanej tzw. generacji rozproszonej. Metodyka ta umożliwia określenie wartości maksymalnej mocy, możliwej do przyłączenia w danym miejscu (miejscach) systemu elektroenergetycznego w źródłach generacji rozproszonej, a w tym pozwala na ocenę wariantów przyłączenia. W metodyce wykorzystuje się funkcję celu, która uwzględnia wymagania stawiane źródłom energii elektrycznej...
-
Optymalizacja rozpływów mocy biernej w systemie elektroenergetycznym
PublicationReferat prezentuje zagadnienia związane ze sterowaniem poziomami napięć w systemie elektroenergetycznym. Rozważane są dwie metody optymalizacji rozpływu mocy biernej, prowadzące do poprawy warunków napięciowych w systemie elektroenergetycznym i ograniczenia strat mocy czynnej. Pierwsza z metod optymalizacyjnych poddanych weryfikacji została zaimplementowana w programie PLANS, a bazuje na autorskiej procedurze opartej o logikę rozmytą,...
-
Propozycja modyfikacji struktury regulatorów turbin parowych
PublicationReferat podejmuje tematykę wpływu struktury regulatora turbiny na proces obrony i odbudowy systemu elektroenergetycznego. Wskazując niedoskonałości obecnie stosowanych regulatorów zaproponowano autorską strukturę regulatora turbiny parowej. Nowy regulator wykorzystuje zalety stosowanych obecnie regulatorów mocy z korektą od częstotliwości, pozwalając jednocześnie na efektywniejsze sterowanie turbinami w stanach awaryjnych, przy...
-
Steam turbines governors in power system restoration process
PublicationThe paper discusses problems related to electric power system restoration process. The turbine controller operating mode influence in small subsystem is analyzed. There are considered abilities, advantages and drawbacks of the controller's two operating modes: power control and speed (frequen-cy) control, to rebuild electric power system from a single generating unit to a few parallel running generators.
-
Wizualizacja i sterowanie urządzeniami w Laboratorium Zarządzania i Integracji Systemów Automatyki Budynków Politechniki Gdańskiej
PublicationLaboratorium Zarządzania i Integracji Systemów Automatyki Budynków powstało na Wydziale Elektrotechniki i Automatyki Politechniki Gdańskiej w ramach jednego z zadań projektu "Sieć certyfikowanych laboratoriów oceny efektywności energetycznej i automatyki budynków" (POIG.02.02.00-00-018/08) współfinansowanego ze środków Unii Europejskiej. W artykule przedstawiono wizualizację i sposób sterowania urządzeniami wdrożone w tym laboratorium....
Year 2011
-
Application capabilities of the maximum distributed generation estimate methodology
PublicationThe paper presents application capabilities of the maximum distributed generation estimate methodology. This subject is an example of solutions to the problem that today face the transmission system operator and distribution system operators, which is related to the high saturation with wind power generation predicted for the near future.
-
Możliwości aplikacyjne metodyki szacowania maksymalnej generacji rozproszonej
PublicationW artykule przedstawiono możliwości aplikacyjne metodyki szacowania maksymalnej generacji rozproszonej. Temat ten jest jednym z przykładowych rozwiązań problemu, który stoi dzisiaj przed operatorem systemu przesyłowego oraz przed operatorami systemów dystrybucyjnych, a związany jest z prognozowanym dużym nasyceniem energetyką wiatrową w najbliższych latach.
-
Możliwości aplikacyjne metodyki szacowania maksymalnej generacji rozproszonej
PublicationW referacie przedstawiono możliwości aplikacyjne metodyki szacowania maksymalnej generacji rozproszonej. Temat ten jest jednym z przykładowych rozwiązań problemu, który stoi dzisiaj przed operatorami systemów dystrybucyjnych, a związany jest z prognozowanym dużym nasyceniem energetyką wiatrową w najbliższych latach.
-
Wykorzystanie rejestracji przebiegów szybkozmiennych do weryfikacji modeli dynamicznych KSE
PublicationW referacie przedstawiono koncepcję narzędzia pozwalającego na weryfikowanie parametrów modeli dynamicznych elementów KSE. Narzędzie wykorzystuje program obliczeniowy PSLF, stosowany powszechnie przez operatora systemu przesyłowego. Nowatorstwo polega na wykorzystaniu dodatkowej aplikacji (programu w systemie MS Windows), która steruje pracą programu obliczeniowego. Powstaje w ten sposób tandem wygodnego interfejsu użytkownika...
-
Wykorzystanie rejestracji przebiegów szybkozmiennych do weryfikacji modeli dynamicznych KSE
PublicationW referacie przedstawiono koncepcję narzędzia pozwalającego na weryfikowanie parametrów modeli dynamicznych elementów KSE. Narzędzie wykorzystuje program obliczeniowy PSLF, stosowany powszechnie przez operatora systemu przesyłowego. Nowatorstwo polega na wykorzystaniu dodatkowej aplikacji (programu w systemie MS Windows), która steruje pracą programu obliczeniowego. Powstaje w ten sposób tandem wygodnego interfejsu użytkownika...
-
Zabezpieczenia impedancyjne bloków energetycznych przy zwarciach bliskich
PublicationW referacie przedstawiono, problematykę działania zabezpieczeń impedancyjnych bloków energetycznych przy zwarciach w pobliżu generatorów. Wskazano, że obecnie stosowane rozwiązania i nastawienia zabezpieczeń mogą być przyczyną ich niewłaściwego działania.
Year 2010
-
Bilansowanie KSE z udziałem procesu regulacji pierwotnej po wypadnięciu źródeł generacji rozproszonej. Cześć I: Praca wydzielona KSE.
PublicationW referacie przedstawiono problem bilansowania mocy czynnej w Krajowym Systemie Elektroenergetycznym po wypadnięciu źródeł generacji rozproszonej. Zakłada się jednocześnie, duże nasycenie energetyką wiatrową, czyli źródłami energii, które obecnie mają największą szanse rozwoju. W referacie analizuje się proces bilansowania mocy czynnej z udziałem regulacji pierwotnej po wypadnięciu określonej liczby źródeł generacji rozproszonej.
-
Bilansowanie KSE z udziałem procesu regulacji pierwotnej po wypadnięciu źródeł generacji rozproszonej. Cześć II: Synchroniczna praca KSE z UCTE.
PublicationReferat jest kontynuacją tematu o takim samym tytule, przy czym rozważana jest w nim praca synchroniczna KSE z UCTE. W referacie tym analizuje się proces bilansowania mocy po wypadnięciu źródeł generacji rozproszonej w ramach regulacji pierwotnej, w której biorą udział bloki wytwórcze w całym UCTE.