Determination of flow properties of a parallel connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.00, b=0.25) from changes in air pressure in a tank being emptied
Description
The aim of the study was to determine the flow properties of parallel connection of pneumatic components.
The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in parallel. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) being emptied tank -> ABG -> ambient atmosphere, (3) being emptied tank -> DCV and ABG in parallel -> ambient atmosphere. So, three data files are included in the dataset. Each data file has a header where parameters of experiment are given. Additionally, for the valves analised , catalogue flow properties are given by means of sonic conductance and critical pressure ratio. The given data allow to verify calculation procedures for determination of flow properties of pneumatic components arranged in parallel.
Dataset file
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
where a single part of the file is 512 MB in size.Example script for calculation:
https://github.com/antespi/s3md5