Mercury intrusion porosimetry (MIP) results of cement pastes containing Bi2O3/Gd2O3 and silica-coated Bi2O3/Gd2O3 structures
Description
Mercury intrusion porosimetry (MIP) data - curves of cement pastes containing Bi2O3/Gd2O3 and silica-coated Bi2O3/Gd2O3 structures
Measurement was performed using Quantachrome Poremaster 60. The mercury surface tension was set at 0.48 N/m and the contact angle was set to 140° upon intrusion. The specimens were placed into measurement cells and filled with mercury in a low-pressure chamber (to 0.34 MPa). Furthermore, the cells were inserted into a pressure chamber and subjected to high pressures (up to 413 MPa).
Data access: PoreMaster (AntonPaar software) or any text editor (e.g. MS Office - Excel or notepad)
Specimen designation is associated with samples designation in the associated manuscript.
REF1001H_Merged - Control cement paste
BG1001H_Merged - BG specimen
A1001H_Merged - A specimen
B1001H_Merged - B specimen
Dataset file
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
where a single part of the file is 512 MB in size.Example script for calculation:
https://github.com/antespi/s3md5
File details
- License:
-
open in new tabCC BYAttribution
- Raw data:
- Data contained in dataset was not processed.
Details
- Year of publication:
- 2024
- Verification date:
- 2024-02-02
- Dataset language:
- English
- Fields of science:
-
- civil engineering, geodesy and transport (Engineering and Technology)
- DOI:
- DOI ID 10.34808/yw9d-zv44 open in new tab
- Funding:
- Verified by:
- West Pomeranian University of Technology in Szczecin
Keywords
References
Cite as
Authors
seen 105 times